25-75 amp, -48 VDC Rectifier System with 25
... Current: 25 amps, full load Regulation: Steady state output voltage remains within ±0.5% in a 46.0 to 57.0 VDC range for any load current (no load to full load) within the specified input voltage and frequency ranges. Protection Current Limiting — Automatic, limits current to 25.5 to 30.0 amps. High ...
... Current: 25 amps, full load Regulation: Steady state output voltage remains within ±0.5% in a 46.0 to 57.0 VDC range for any load current (no load to full load) within the specified input voltage and frequency ranges. Protection Current Limiting — Automatic, limits current to 25.5 to 30.0 amps. High ...
ZR431L Adjustable precision shunt regulator Summary Description
... The product specifications contained in this publication are issued to provide outline information only which (unless agreed by the company in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the prod ...
... The product specifications contained in this publication are issued to provide outline information only which (unless agreed by the company in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the prod ...
TS19730 - Beck Elektronik
... assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of ...
... assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of ...
Low-Voltage Current Sink Controls High-Voltage
... the output voltage to provide 1.2 V on FB and thus on D2. This is enough to allow accurate current regulation. As the current through D2’s current sink changes, the ADP1612 automatically scales the output voltage to deliver exactly enough voltage to power the LEDs and the current sink. The ADP8860 h ...
... the output voltage to provide 1.2 V on FB and thus on D2. This is enough to allow accurate current regulation. As the current through D2’s current sink changes, the ADP1612 automatically scales the output voltage to deliver exactly enough voltage to power the LEDs and the current sink. The ADP8860 h ...
Meaning of symbol
... CAUTION! Please consult the operating instructions before using the device. In these operating instructions, failure to follow or carry out instructions preceded by this symbol may result in personal injury or damage to the device and the installations. ...
... CAUTION! Please consult the operating instructions before using the device. In these operating instructions, failure to follow or carry out instructions preceded by this symbol may result in personal injury or damage to the device and the installations. ...
Problem 2 - Roletech
... only at the desired frequency, with an amplitude proportional to the size of the desired portion of the incoming signal. Transformer action causes this signal to be reproduced at the secondary side of the transformer. ...
... only at the desired frequency, with an amplitude proportional to the size of the desired portion of the incoming signal. Transformer action causes this signal to be reproduced at the secondary side of the transformer. ...
A Miniature Relay with 1-pole 3A/5A Switching Capability
... GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) ...
... GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) ...
S2 Topic 4 Making Use of Electricity
... - We use an ammeter to measure electric currents. - Ampere is the unit of an electric current. - Voltage is the push that makes electric current flow in a circuit. - We use a voltmeter to measure voltage. - Volt is the unit of voltage. - An electrical conductor allows electric current to pass throug ...
... - We use an ammeter to measure electric currents. - Ampere is the unit of an electric current. - Voltage is the push that makes electric current flow in a circuit. - We use a voltmeter to measure voltage. - Volt is the unit of voltage. - An electrical conductor allows electric current to pass throug ...
A discussion of basic differential equation applications
... Chapter 9: Basic Differential Equation Applications A differential equation is an equation involving derivatives. These equations often involve both the independent variable, say t, the dependent variable, say y (which is a function of t), and the derivative dy , and possibly higher derivatives. The ...
... Chapter 9: Basic Differential Equation Applications A differential equation is an equation involving derivatives. These equations often involve both the independent variable, say t, the dependent variable, say y (which is a function of t), and the derivative dy , and possibly higher derivatives. The ...
TL1591 SAMPLE-AND-HOLD CIRCUIT FOR CCD IMAGERS •
... Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 25°C to 80°C Storage temperature range, TSTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 150°C † Stresses ...
... Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 25°C to 80°C Storage temperature range, TSTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 150°C † Stresses ...
How to use the design tool (Ver 1.0) for FAN7631 www.fairchildsemi.com 1
... 1) 0.2~0.26 for fr=100kHz 2) 0.15~0.2 for fr=200kHz 3) 0.1~0.15 for fr=300kHzis recommended. ...
... 1) 0.2~0.26 for fr=100kHz 2) 0.15~0.2 for fr=200kHz 3) 0.1~0.15 for fr=300kHzis recommended. ...
ppt
... As process technology improves, more devices will be integrated onto a chip, designs will grow more ...
... As process technology improves, more devices will be integrated onto a chip, designs will grow more ...
EUP7907A 数据手册DataSheet 下载
... There are no requirements for the ESR on the input capacitor, but the tolerance and temperature coefficient must be considered when selecting the capacitor to ensure the capacitance will be 2.2uF over the whole operating temperature range. Output Capacitor The EUP7907A is designed specifically to wo ...
... There are no requirements for the ESR on the input capacitor, but the tolerance and temperature coefficient must be considered when selecting the capacitor to ensure the capacitance will be 2.2uF over the whole operating temperature range. Output Capacitor The EUP7907A is designed specifically to wo ...
RTCA SC-135 and EUROCAE WG-14
... 22-2 (Note: when testing pins which normally have a bias voltage, i.e. power line inputs or other sources, this voltage must be added to the peak test voltage of Table 22-2). This test voltage may be applied from each pin to case or from all pins, simultaneously, to case. b. Power shall be applied t ...
... 22-2 (Note: when testing pins which normally have a bias voltage, i.e. power line inputs or other sources, this voltage must be added to the peak test voltage of Table 22-2). This test voltage may be applied from each pin to case or from all pins, simultaneously, to case. b. Power shall be applied t ...