Qucs - A Tutorial
... Operation amplifiers (OP AMP) are a fundamental building block of linear electronics. They have been widely employed in linear circuit design since they were first introduced over thirty years ago. The use of operational amplifier models for circuit simulation using SPICE and other popular circuit s ...
... Operation amplifiers (OP AMP) are a fundamental building block of linear electronics. They have been widely employed in linear circuit design since they were first introduced over thirty years ago. The use of operational amplifier models for circuit simulation using SPICE and other popular circuit s ...
Study on RF Characteristics and Modeling of Scaled MOSFET
... Resistance, capacitance or inductance included in the interconnect lines or bonding pads, which could neglect approximately in DC measurements (not completely neglect as for the interconnect lines resistance), largely influence to device RF performance. These parasitic components must be removed to ...
... Resistance, capacitance or inductance included in the interconnect lines or bonding pads, which could neglect approximately in DC measurements (not completely neglect as for the interconnect lines resistance), largely influence to device RF performance. These parasitic components must be removed to ...
SP3281
... The SP3281EB device is an RS-232 transceiver solution intended for portable or hand-held applications such as notebook and palmtop computers, PDAs, cell phones and their data cables and cradles. The SP3281EB is compatible with low voltage logic down to 1.8V using a logic select pin (VL) which condit ...
... The SP3281EB device is an RS-232 transceiver solution intended for portable or hand-held applications such as notebook and palmtop computers, PDAs, cell phones and their data cables and cradles. The SP3281EB is compatible with low voltage logic down to 1.8V using a logic select pin (VL) which condit ...
A CMOS low power, process/temperature variation tolerant RSSI
... Generally, there are two types of circuits applied for magnitude control, namely the automatically gain-controlled amplifier (AGC) and the limiting amplifier (LA). An AGC consists of an amplifier with controllable gain and a magnitude detector for gain adjustment. Configured as a closed-loop structu ...
... Generally, there are two types of circuits applied for magnitude control, namely the automatically gain-controlled amplifier (AGC) and the limiting amplifier (LA). An AGC consists of an amplifier with controllable gain and a magnitude detector for gain adjustment. Configured as a closed-loop structu ...
No Slide Title
... Figure 4.10 (a) Circuit symbol for the n-channel enhancement-type MOSFET. (b) Modified circuit symbol with an arrowhead on the source terminal to distinguish it from the drain and to indicate device polarity (i.e., n channel). (c) Simplified circuit symbol to be used when the source is connected to ...
... Figure 4.10 (a) Circuit symbol for the n-channel enhancement-type MOSFET. (b) Modified circuit symbol with an arrowhead on the source terminal to distinguish it from the drain and to indicate device polarity (i.e., n channel). (c) Simplified circuit symbol to be used when the source is connected to ...
IN618
... • Normally cable bundle tests are done with all shields that are present in the bundle connected at both ends. If the shield current limits cannot be reached by the available test equipment, it is allowable to test with shields disconnected and pulse the core wires directly. This note points out bel ...
... • Normally cable bundle tests are done with all shields that are present in the bundle connected at both ends. If the shield current limits cannot be reached by the available test equipment, it is allowable to test with shields disconnected and pulse the core wires directly. This note points out bel ...
2 marks - crypt
... a) i) Which lamp/s will be lit if switch H is closed, but switch F open? The headlamp will be on, but the fog lamp off (2 marks) ii) If switch F is closed, while switch H is open, which lamp/s will be lit? With F closed, but H open there is a complete circuit for the two lamps in series. They will b ...
... a) i) Which lamp/s will be lit if switch H is closed, but switch F open? The headlamp will be on, but the fog lamp off (2 marks) ii) If switch F is closed, while switch H is open, which lamp/s will be lit? With F closed, but H open there is a complete circuit for the two lamps in series. They will b ...
INVERTEK®
... The battery temperature sensor supplied with the product may be used for temperature compensated charging, see page 3-4 and 3-5. The sensor is insulated and must be mounted on the batteries minus pole. 1.6.4 3 Sets of Auxiliary Relay (RY1, RY2, RY3) Output The “Combi 3” provides 3 sets of Auxiliary ...
... The battery temperature sensor supplied with the product may be used for temperature compensated charging, see page 3-4 and 3-5. The sensor is insulated and must be mounted on the batteries minus pole. 1.6.4 3 Sets of Auxiliary Relay (RY1, RY2, RY3) Output The “Combi 3” provides 3 sets of Auxiliary ...
ZXT10P20DE6 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
QS20.481 - PULS Power Supply
... - Turn power off before working on the device. Protect against inadvertent re-powering. - Make sure that the wiring is correct by following all local and national codes. - Do not modify or repair the unit. - Do not open the unit as high voltages are present inside. - Use caution to prevent any forei ...
... - Turn power off before working on the device. Protect against inadvertent re-powering. - Make sure that the wiring is correct by following all local and national codes. - Do not modify or repair the unit. - Do not open the unit as high voltages are present inside. - Use caution to prevent any forei ...
MAX487CPA+中文资料
... functionaloperation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure toabsolute maximum rating conditions for extended periods may affect device ...
... functionaloperation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure toabsolute maximum rating conditions for extended periods may affect device ...
Time-Current Curves (How to Read)
... extinguished. Consequently, the final overcurrent termination can vary over a wide range of time, as is indicated by the wide band between the unlatching time curve and the maximum interrupting time curve. The instantaneous trip setting for larger molded case and power breakers can usually be adjust ...
... extinguished. Consequently, the final overcurrent termination can vary over a wide range of time, as is indicated by the wide band between the unlatching time curve and the maximum interrupting time curve. The instantaneous trip setting for larger molded case and power breakers can usually be adjust ...