I-320 Specification Sheet
... The I-320 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I-320 switches to the emergency mode and operates one of the existing lamps for 90 minutes. The unit cont ...
... The I-320 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I-320 switches to the emergency mode and operates one of the existing lamps for 90 minutes. The unit cont ...
14 Lighting Concepts 2
... Fluorescent History • Worked on by Edison & Tesla in the 1890s • Daniel Moore worked on Edison’s ideas and developed it further up to a working system until in 1904 a number were installed in shops and offices ...
... Fluorescent History • Worked on by Edison & Tesla in the 1890s • Daniel Moore worked on Edison’s ideas and developed it further up to a working system until in 1904 a number were installed in shops and offices ...
Lamps, LEDs and Circuits
... How they work The discharge in the linearly extended ceramic discharge tube is defined by sodium, so the light is yellowish and only suitable for certain applications although colour improved versions of the lamp do exist, An ignitor is needed to switch on the lamp (although some lamps have a built- ...
... How they work The discharge in the linearly extended ceramic discharge tube is defined by sodium, so the light is yellowish and only suitable for certain applications although colour improved versions of the lamp do exist, An ignitor is needed to switch on the lamp (although some lamps have a built- ...
for High Bay Installations - Universal Lighting Technologies
... where today’s T5HO high lumen fluorescent systems are specified. Designed with high efficiency electronic technology and constructed formaximum thermal dissipation, these ballasts can provide long reliable service in high temperature installations where HID systems are typically installed. 4-Lamp T5 ...
... where today’s T5HO high lumen fluorescent systems are specified. Designed with high efficiency electronic technology and constructed formaximum thermal dissipation, these ballasts can provide long reliable service in high temperature installations where HID systems are typically installed. 4-Lamp T5 ...
LED EMERGENCY BALLAST
... with the AC ballast to allow the same fluorescent fixture to be used for both normal and emergency operations. When AC power fails, the VEM700DV-L switches to emergency mode and keeps the lamp(s) illuminated at a reduced lumen output for a minimum of 90 minutes. The VEM700DV-L is suitable for use in ...
... with the AC ballast to allow the same fluorescent fixture to be used for both normal and emergency operations. When AC power fails, the VEM700DV-L switches to emergency mode and keeps the lamp(s) illuminated at a reduced lumen output for a minimum of 90 minutes. The VEM700DV-L is suitable for use in ...
Electronic Ballast Fundamentals
... lamps : 2 to 4 times more efficient The lamps last a lot longer – 10k to 20k hours versus 0.75k to 1k hours for an incandescent lamp The lamps are much cooler than incandescent lamps ...
... lamps : 2 to 4 times more efficient The lamps last a lot longer – 10k to 20k hours versus 0.75k to 1k hours for an incandescent lamp The lamps are much cooler than incandescent lamps ...
A120F32S - Philips Bodine
... a galvanized 22 guage steel case, operate one lamp at 32 kHz from 120 VAC, 50/60 Hz. It shall be instant start, operate at minimum 80% efficiency, be high power factor (90% minimum) and have an EMI filter. The ballast shall be UL Listed, warranted for three years and made in the U.S.A. ...
... a galvanized 22 guage steel case, operate one lamp at 32 kHz from 120 VAC, 50/60 Hz. It shall be instant start, operate at minimum 80% efficiency, be high power factor (90% minimum) and have an EMI filter. The ballast shall be UL Listed, warranted for three years and made in the U.S.A. ...
xeb-t5-5-b-lm Series
... performance in a slim design. This unit is ideal for use in linear lighting fixtures where ballast compartment space is limited. The XEB-T5-5-BLM is U.L. Listed for factory installation or retrofit applications. The unit contains a battery, charger and inverter circuit in a single can and has an ini ...
... performance in a slim design. This unit is ideal for use in linear lighting fixtures where ballast compartment space is limited. The XEB-T5-5-BLM is U.L. Listed for factory installation or retrofit applications. The unit contains a battery, charger and inverter circuit in a single can and has an ini ...
Detailed Specifications - Cooper Electric Supply
... welded 20GA housing stands up to vibrations and other environmental factors. A one-piece deep symmetrical reflector shields and controls the lamp output. • Applications: Use for all commercial, industrial and retail general area lighting applications. Industrial reflectors direct 100% of the illumi ...
... welded 20GA housing stands up to vibrations and other environmental factors. A one-piece deep symmetrical reflector shields and controls the lamp output. • Applications: Use for all commercial, industrial and retail general area lighting applications. Industrial reflectors direct 100% of the illumi ...
Electronic ballasts (EB) Technical Details - Vossloh
... the electrodes every time the lamp is started and thus reduce the lamp's service life. Furthermore, care should be taken to prevent crossdischarge in the electrode area during preheating, which also shortens lamp service life. Electromagnetic (inductive) ballasts have to be operated in conjunction w ...
... the electrodes every time the lamp is started and thus reduce the lamp's service life. Furthermore, care should be taken to prevent crossdischarge in the electrode area during preheating, which also shortens lamp service life. Electromagnetic (inductive) ballasts have to be operated in conjunction w ...
IOTA I-48 Product Specification Sheet
... The I-48 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I-48 switches to the emergency mode and operates one or two of the existing lamps for 90 minutes. The unit ...
... The I-48 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I-48 switches to the emergency mode and operates one or two of the existing lamps for 90 minutes. The unit ...
I-32 Reduced Profile Fluorescent Emergency Ballast Specification
... *Refer to Lumen Reference Chart for list of compatible lamps ...
... *Refer to Lumen Reference Chart for list of compatible lamps ...
Detailed Specifications - Cooper Electric Supply
... with ample bends for uniformity and strength. Design embossed end plates are riveted onto housing. Wireway cover snaps into housing for easy maintenance. Finished with a high quality white enamel paint baked on to provide an 87% minimum reflectivity. ...
... with ample bends for uniformity and strength. Design embossed end plates are riveted onto housing. Wireway cover snaps into housing for easy maintenance. Finished with a high quality white enamel paint baked on to provide an 87% minimum reflectivity. ...
Fluorescent lamp

A fluorescent lamp or a fluorescent tube is a low pressure mercury-vapor gas-discharge lamp that uses fluorescence to produce visible light. An electric current in the gas excites mercury vapor which produces short-wave ultraviolet light that then causes a phosphor coating on the inside of the bulb to glow. A fluorescent lamp converts electrical energy into useful light much more efficiently than incandescent lamps. The typical luminous efficacy of fluorescent lighting systems is 50–100 lumens per watt, several times the efficacy of incandescent bulbs with comparable light output.Fluorescent lamp fixtures are more costly than incandescent lamps because they require a ballast to regulate the current through the lamp, but the lower energy cost typically offsets the higher initial cost. Compact fluorescent lamps are now available in the same popular sizes as incandescents and are used as an energy-saving alternative in homes.Because they contain mercury, many fluorescent lamps are classified as hazardous waste. The United States Environmental Protection Agency recommends that fluorescent lamps be segregated from general waste for recycling or safe disposal.