MAX8863T/S/R, MAX8864T/S/R Low-Dropout, 120mA Linear Regulators __________________General Description
... Larger input capacitor values and lower ESR provide better supply-noise rejection and transient response. A higher-value input capacitor (10µF) may be necessary ...
... Larger input capacitor values and lower ESR provide better supply-noise rejection and transient response. A higher-value input capacitor (10µF) may be necessary ...
Digital Protection for Power Systems
... relays to suit the requirements of the components used. Ideally the current transformer would reproduce a perfectly scaled down version of the primary signal on its secondary side. Practical transformers reproduce the secondary current with some error, because these devices incorporate 'non-ideal' e ...
... relays to suit the requirements of the components used. Ideally the current transformer would reproduce a perfectly scaled down version of the primary signal on its secondary side. Practical transformers reproduce the secondary current with some error, because these devices incorporate 'non-ideal' e ...
AKSHAYA COLLEGE OF ENGINEERING AND TECHNOLOGY
... 12. What is meant by depletion region? In PN junction, the diffusion of holes and electrons start initially. Near the junction, holes recombine in N-region to form immobile positive ions. Similarly electrons recombine in P-region to form immobile negative ions. With sufficient accumulation of such ...
... 12. What is meant by depletion region? In PN junction, the diffusion of holes and electrons start initially. Near the junction, holes recombine in N-region to form immobile positive ions. Similarly electrons recombine in P-region to form immobile negative ions. With sufficient accumulation of such ...
Experiment 2: Measurements on DC circuits
... circuit. Once the electrical parameters (voltage and/or current) have been determined for the equivalent resistances, the voltages and/or currents for the individual resistors in the series or parallel combinations can be obtained by using these parameters as Vs and Is for the corresponding combinat ...
... circuit. Once the electrical parameters (voltage and/or current) have been determined for the equivalent resistances, the voltages and/or currents for the individual resistors in the series or parallel combinations can be obtained by using these parameters as Vs and Is for the corresponding combinat ...
Low voltage CMOS 3 to 8 line decoder with 5V tolerant inputs
... silicon gate and double-layer metal wiring C2MOS technology. It is ideal for low power, battery operated and low noise 3.3V applications. If the device is enabled, 3 binary select (A, B, and C) determine which one of the outputs will go high. If enable input G1 is held low or either G2A or G2B ...
... silicon gate and double-layer metal wiring C2MOS technology. It is ideal for low power, battery operated and low noise 3.3V applications. If the device is enabled, 3 binary select (A, B, and C) determine which one of the outputs will go high. If enable input G1 is held low or either G2A or G2B ...
Ameritron AL-1200 to gs35b Conversion
... was the original; the tube suffered some catastrophic failure many years ago, and the amplifier had been sitting around since. On inspection (always a good thing to do to understand what you have), I found that the 'slow-start' or reduced voltage turn on resistor was open and charred (perhaps a shor ...
... was the original; the tube suffered some catastrophic failure many years ago, and the amplifier had been sitting around since. On inspection (always a good thing to do to understand what you have), I found that the 'slow-start' or reduced voltage turn on resistor was open and charred (perhaps a shor ...
Catalog 3.5
... – reversing motor development from star into triangle – fan is still in use after switching-off – controlling of vehicle doors ...
... – reversing motor development from star into triangle – fan is still in use after switching-off – controlling of vehicle doors ...
Superposition , Thevenin / Norton Equivalents
... So, another way to analyze a circuit is to find the contribution of each source individually and them add them up at the end to get the total. ...
... So, another way to analyze a circuit is to find the contribution of each source individually and them add them up at the end to get the total. ...
Load-commutated Current Source Inverter (CSI)
... was presented. Two commutating capacitors, along with four diodes, are used in the above circuit for commutation from one pair of thyristors to the second pair. Earlier, also in VSI, if the load is capacitive, it was shown that forced commutation may not be needed. The operation of a single-phase CS ...
... was presented. Two commutating capacitors, along with four diodes, are used in the above circuit for commutation from one pair of thyristors to the second pair. Earlier, also in VSI, if the load is capacitive, it was shown that forced commutation may not be needed. The operation of a single-phase CS ...
7872A - Data Device Corporation
... - Analog input range of ±3V - 83 KSPS throughput rate - Operates with +5V/-5V power supplies - 80 dB SNR at 10 kHz input frequency - Serial output ...
... - Analog input range of ±3V - 83 KSPS throughput rate - Operates with +5V/-5V power supplies - 80 dB SNR at 10 kHz input frequency - Serial output ...
7872 Data Sheet 04.14.15 Rev 6.fm
... - Analog input range of ±3V - 83 KSPS throughput rate - Operates with +5V/-5V power supplies - 80 dB SNR at 10 kHz input frequency - Serial output ...
... - Analog input range of ±3V - 83 KSPS throughput rate - Operates with +5V/-5V power supplies - 80 dB SNR at 10 kHz input frequency - Serial output ...
AC Adapters - Mode Electronics
... 68-650-1 will be replaced with the 68-6500S-1 when current stock is depleted. 68-650P-1 will be replaced with the 68-6500PS-1 when current stock is depleted. 68-950-1 is now replaced by 68-9006S-1 (600mA). 68-950P-1 will be replaced with the 68-9006PS-1 (600mA) when current stock is depleted. 68-121 ...
... 68-650-1 will be replaced with the 68-6500S-1 when current stock is depleted. 68-650P-1 will be replaced with the 68-6500PS-1 when current stock is depleted. 68-950-1 is now replaced by 68-9006S-1 (600mA). 68-950P-1 will be replaced with the 68-9006PS-1 (600mA) when current stock is depleted. 68-121 ...
Precision, Low Power INSTRUMENTATION AMPLIFIER INA118
... voltages up to ±40V. For example, a condition of –40V on one input and +40V on the other input will not cause damage. Internal circuitry on each input provides low series impedance under normal signal conditions. To provide equivalent protection, series input resistors would contribute excessive noi ...
... voltages up to ±40V. For example, a condition of –40V on one input and +40V on the other input will not cause damage. Internal circuitry on each input provides low series impedance under normal signal conditions. To provide equivalent protection, series input resistors would contribute excessive noi ...
Basler Electric AVC63-12 and AVC125
... 1 PU V/Hz. No connection to terminal 8 will result in an underfrequency slope of 2 PU V/Hz. The slope can also be selected on the 400 Hz models. However, the actual V/Hz curve is approximately 1 PU or 2 PU, depending if terminal 8 is jumpered to 6a. Stability (STB) An oscilloscope or other voltage r ...
... 1 PU V/Hz. No connection to terminal 8 will result in an underfrequency slope of 2 PU V/Hz. The slope can also be selected on the 400 Hz models. However, the actual V/Hz curve is approximately 1 PU or 2 PU, depending if terminal 8 is jumpered to 6a. Stability (STB) An oscilloscope or other voltage r ...
LECT7V23_printvers
... We can get a good approximation for r by using the following relationship. o r =V /I o A C The V , the Early voltage, is another parameter we must be given. It is typically in the A range of 50-100[V]. Note also that I is the dc value of the collector current. C With this, we can get a pretty good m ...
... We can get a good approximation for r by using the following relationship. o r =V /I o A C The V , the Early voltage, is another parameter we must be given. It is typically in the A range of 50-100[V]. Note also that I is the dc value of the collector current. C With this, we can get a pretty good m ...
Electronic Engineering
... The graphical method uses plots of the input and output characteristics to determine the characteristics of the created amplifier or circuit. This requires a large amount of graphical information to be available especially if a design is being formulated with a wide range of possible devices to be c ...
... The graphical method uses plots of the input and output characteristics to determine the characteristics of the created amplifier or circuit. This requires a large amount of graphical information to be available especially if a design is being formulated with a wide range of possible devices to be c ...
DM74LS74A Dual Positive-Edge-Triggered D Flip
... Note 7: All typicals are at VCC = 5V, TA = 25°C. Note 8: Not more than one output should be shorted at a time, and the duration should not exceed one second. For devices, with feedback from the outputs, where shorting the outputs to ground may cause the outputs to change logic state an equivalent te ...
... Note 7: All typicals are at VCC = 5V, TA = 25°C. Note 8: Not more than one output should be shorted at a time, and the duration should not exceed one second. For devices, with feedback from the outputs, where shorting the outputs to ground may cause the outputs to change logic state an equivalent te ...
Sizing the UCC3913 Charge-Pump Capacitor
... any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI wa ...
... any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI wa ...
Development of a new controller for absolute cavity, cavity
... known in industry for rugged dataloggers with quality measurements. Detailed specifications are available at Campbell’s website.e The WMO-based classifications of a standard pyrheliometer requires a resolution of 0.51 W/m2. To achieve this, the accuracy for the thermopile voltage measurement needs t ...
... known in industry for rugged dataloggers with quality measurements. Detailed specifications are available at Campbell’s website.e The WMO-based classifications of a standard pyrheliometer requires a resolution of 0.51 W/m2. To achieve this, the accuracy for the thermopile voltage measurement needs t ...
Low Cost Digital Panel Meter Designs and Complete
... The precise value is determined by the point at which the integrator output ramps within ~0.3V of one or other of the supply rails. This is governed by the integrator time constant, the magnitude and polarity of the input, the common mode voltage, and the clock frequency: for further details, consul ...
... The precise value is determined by the point at which the integrator output ramps within ~0.3V of one or other of the supply rails. This is governed by the integrator time constant, the magnitude and polarity of the input, the common mode voltage, and the clock frequency: for further details, consul ...
Integrating ADC
An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.