Full Text - Centre of Biomedical Engineering
... The first block is the EDR sensor, which is placed on the subject’s hand to evaluate EDR. The measured EDR is passed to Launchpad for further conversion to a digital signal. The Launchpad Kit is used as the SYSTEM module or the second block shown in Fig. 3. It includes the built-in circuits and nece ...
... The first block is the EDR sensor, which is placed on the subject’s hand to evaluate EDR. The measured EDR is passed to Launchpad for further conversion to a digital signal. The Launchpad Kit is used as the SYSTEM module or the second block shown in Fig. 3. It includes the built-in circuits and nece ...
Full-Text PDF
... is below the main resonant frequency, LLC can both attain ZVS for primary power switches and zero-current-switching (ZCS) for output rectifiers [14]. Additionally, the converter benefits from a narrow switching frequency range with light load and ZVS capability, even with no load [15–19]. The compar ...
... is below the main resonant frequency, LLC can both attain ZVS for primary power switches and zero-current-switching (ZCS) for output rectifiers [14]. Additionally, the converter benefits from a narrow switching frequency range with light load and ZVS capability, even with no load [15–19]. The compar ...
AD7858 数据手册DataSheet下载
... t14 is derived form the measured time taken by the data outputs to change 0.5 V when loaded with the circuit of Figure 1. The measured number is then extrapolated back to remove the effects of charging or discharging the 100 pF capacitor. This means that the time quoted in the Timing Characteristics ...
... t14 is derived form the measured time taken by the data outputs to change 0.5 V when loaded with the circuit of Figure 1. The measured number is then extrapolated back to remove the effects of charging or discharging the 100 pF capacitor. This means that the time quoted in the Timing Characteristics ...
MPC5606E Microcontroller Data Sheet
... connecting a 25 MHz crystal between these two pins or by driving XTALI with an external 25 MHz clock. when using a crystal, connect a loading capacitor from each pin to GND. ...
... connecting a 25 MHz crystal between these two pins or by driving XTALI with an external 25 MHz clock. when using a crystal, connect a loading capacitor from each pin to GND. ...
ACS716: 120 kHz Bandwidth, High-Voltage Isolation Current Sensor
... Over full scale of IPOA , IP applied for 5 ms, TA = – 40°C to 25°C ...
... Over full scale of IPOA , IP applied for 5 ms, TA = – 40°C to 25°C ...
Noise in relaxation oscillators
... 2) It is plausible that the jitter will be directly proportional to the rms noise current for a fixed slope of the timing waveform. 3) If the dominant noise power in the oscillator lies at high frequencies, it acts to reduce the mean period of oscillation. This is evident from Fig. 8, where the ramp ...
... 2) It is plausible that the jitter will be directly proportional to the rms noise current for a fixed slope of the timing waveform. 3) If the dominant noise power in the oscillator lies at high frequencies, it acts to reduce the mean period of oscillation. This is evident from Fig. 8, where the ramp ...
Agilent 34401A Digital Multimeter
... However, the 34401A may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently wired motors. Such devices and circuits are subject to overvoltages that may exceed the prot ...
... However, the 34401A may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently wired motors. Such devices and circuits are subject to overvoltages that may exceed the prot ...
AT10.1 SERIES CHARGERS AT10.1 SERIES CHARGERS
... receipt before signing, and notify the delivery person of your findings. If loss or damage is discovered after delivery, notify delivering carrier immediately and request an inspection. The manufacturer does not assume any liability for damage during transportation or handling. Should the goods requ ...
... receipt before signing, and notify the delivery person of your findings. If loss or damage is discovered after delivery, notify delivering carrier immediately and request an inspection. The manufacturer does not assume any liability for damage during transportation or handling. Should the goods requ ...
TANGO PCIe | Operating Manual
... when the status LED lights up. Make sure that during this period of time the joystick doesn't get shifted. The result would be that the zero point would also be shifted and axes would move when letting go of the joystick! ● Connect PC with socket and switch on, if necessary together with the externa ...
... when the status LED lights up. Make sure that during this period of time the joystick doesn't get shifted. The result would be that the zero point would also be shifted and axes would move when letting go of the joystick! ● Connect PC with socket and switch on, if necessary together with the externa ...
thyro-a - Advanced Energy
... The device may only be used for the purpose for which it was intended, as persons may otherwise be exposed to dangers (e. g. electric shock, burns) and plants also (e. g. overload). The user must therefore observe the following points: • It is not permitted to make any unauthorised modifications to ...
... The device may only be used for the purpose for which it was intended, as persons may otherwise be exposed to dangers (e. g. electric shock, burns) and plants also (e. g. overload). The user must therefore observe the following points: • It is not permitted to make any unauthorised modifications to ...
MX15 Series AC and DC Power Source User Manual
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
MX15 Series AC and DC Power Source User Manual
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
Installation Considerations for Multi
... these equations. Measured surge impedance was also used in a simulation program designed to predict Ilg magnitude for various system conditions. A PWM output filter and an input isolation transformer with the neutral high resistance grounded were two solutions investigated to reduce the zero sequenc ...
... these equations. Measured surge impedance was also used in a simulation program designed to predict Ilg magnitude for various system conditions. A PWM output filter and an input isolation transformer with the neutral high resistance grounded were two solutions investigated to reduce the zero sequenc ...
All About LEDs
... We connect our LED through a 1K resistor, as we adjust the voltage from 0 volts to infinite volts, what happens? As the voltages goes higher and higher, the LED will get brighter. As the voltages goes higher and higher, the LED will get brighter. It would seem, then, that if we want a r ...
... We connect our LED through a 1K resistor, as we adjust the voltage from 0 volts to infinite volts, what happens? As the voltages goes higher and higher, the LED will get brighter. As the voltages goes higher and higher, the LED will get brighter. It would seem, then, that if we want a r ...
16-Bit, 1.5 LSB INL, 250 kSPS PulSAR™ Differential ADC in MSOP/QFN AD7687
... The AD7687 is a 16-bit, charge redistribution, successive approximation, analog-to-digital converter (ADC) that operates from a single power supply, VDD, between 2.3 V to 5.5 V. It contains a low power, high speed, 16-bit sampling ADC with no missing codes, an internal conversion clock, and a versat ...
... The AD7687 is a 16-bit, charge redistribution, successive approximation, analog-to-digital converter (ADC) that operates from a single power supply, VDD, between 2.3 V to 5.5 V. It contains a low power, high speed, 16-bit sampling ADC with no missing codes, an internal conversion clock, and a versat ...
Integrating ADC
An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.