MAX1246/MAX1247 +2.7V, Low-Power, 4-Channel, Serial 12-Bit ADCs in QSOP-16 General Description
... Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the full-scale range has been calibrated. Note 3: MAX1246—internal reference, offset nulled; MAX1247—external reference (VREF = +2.500V), offset nulled. Note 4: Ground “on” channel; sine wave ...
... Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the full-scale range has been calibrated. Note 3: MAX1246—internal reference, offset nulled; MAX1247—external reference (VREF = +2.500V), offset nulled. Note 4: Ground “on” channel; sine wave ...
Power Monitor - Cypress Semiconductor
... terminal with name “rtn” which can be connected to reference ground point to measure the differential voltage. UVWarn[x] – This parameter helps to set the Under-Voltage (UV) warning threshold for the specified power converter. The allowed warning threshold range is 0.001-65.535 V. By default, the co ...
... terminal with name “rtn” which can be connected to reference ground point to measure the differential voltage. UVWarn[x] – This parameter helps to set the Under-Voltage (UV) warning threshold for the specified power converter. The allowed warning threshold range is 0.001-65.535 V. By default, the co ...
a AN-574 APPLICATION NOTE
... current channel input—see Corrected Phase Matching between Channels and Antialias Filters in this application note. In this design, a 5000 turn CT was chosen. The nominal value of the burden resistor can be found by the following calculation: ...
... current channel input—see Corrected Phase Matching between Channels and Antialias Filters in this application note. In this design, a 5000 turn CT was chosen. The nominal value of the burden resistor can be found by the following calculation: ...
585 TECPak User's Manual
... resistance of the sensor at the desired or actual temperature. While most users will only need the temperature control mode, the constant resistance mode allows you to bypass the sensor equation and directly select the sensor set point. This can be useful when only the desired sensor value is known, ...
... resistance of the sensor at the desired or actual temperature. While most users will only need the temperature control mode, the constant resistance mode allows you to bypass the sensor equation and directly select the sensor set point. This can be useful when only the desired sensor value is known, ...
september - Linear Technology
... and the RT1 input pin. Time position resistors and the corresponding ideal time position voltages are given in Table 2. To configure time position 5 for supply S1, a 9.53kΩ resistor is selected. Time positions 6, 7 and 8 are similarly selected with RT resistors for supplies S2, S3 and S4. Any sequenc ...
... and the RT1 input pin. Time position resistors and the corresponding ideal time position voltages are given in Table 2. To configure time position 5 for supply S1, a 9.53kΩ resistor is selected. Time positions 6, 7 and 8 are similarly selected with RT resistors for supplies S2, S3 and S4. Any sequenc ...
Design Optimization of High Frequency Transformer for Dual Active
... leakage inductance and the phase-shifted angle between its terminal square wave voltages. As a result, there is always a trade-off between the leakage inductance and the phaseshifted angle when maximizing the power conversion. Additionally, at high switching frequency, high AC losses in the HFT wind ...
... leakage inductance and the phase-shifted angle between its terminal square wave voltages. As a result, there is always a trade-off between the leakage inductance and the phaseshifted angle when maximizing the power conversion. Additionally, at high switching frequency, high AC losses in the HFT wind ...
Nodal Analysis
... In this method, we set up and solve a system of equations in which the unknowns are the voltages at the principal nodes of the circuit. From these nodal voltages the currents in the various branches of the circuit are easily determined. The steps in the nodal analysis method are: ...
... In this method, we set up and solve a system of equations in which the unknowns are the voltages at the principal nodes of the circuit. From these nodal voltages the currents in the various branches of the circuit are easily determined. The steps in the nodal analysis method are: ...
ECE 469 Power Electronics Lab Manual
... Safety The Power Electronics Laboratory deals with power levels much higher than those in most electronics settings. In ECE 469, the voltages will usually be kept low to minimize hazards. Be careful when working with spinning motors, and parts that can become hot. Most of our equipment is rugged, bu ...
... Safety The Power Electronics Laboratory deals with power levels much higher than those in most electronics settings. In ECE 469, the voltages will usually be kept low to minimize hazards. Be careful when working with spinning motors, and parts that can become hot. Most of our equipment is rugged, bu ...
a AN-402 APPLICATION NOTE •
... Various clamp amps can be used in these systems to restrict signal excursions at their outputs to protect downstream devices. So far most of the clamping amplifiers have relied upon an output clamping architecture and are called output clamp amps (OCAs). A new architecture called an input clamp amp ...
... Various clamp amps can be used in these systems to restrict signal excursions at their outputs to protect downstream devices. So far most of the clamping amplifiers have relied upon an output clamping architecture and are called output clamp amps (OCAs). A new architecture called an input clamp amp ...
Capacitor
... in AC or DC regimes, the capacitor doesn't - a capacitor will in general not conduct DC current, so it's influence becomes obvious only in AC and signal regime. ...
... in AC or DC regimes, the capacitor doesn't - a capacitor will in general not conduct DC current, so it's influence becomes obvious only in AC and signal regime. ...
LM2900, LM3900 QUADRUPLE NORTON OPERATIONAL AMPLIFIERS D
... Norton (or current-differencing) amplifiers can be used in most standard general-purpose operational amplifier applications. Performance as a dc amplifier in a single-power-supply mode is not as precise as a standard integrated-circuit operational amplifier operating from dual supplies. Operation of ...
... Norton (or current-differencing) amplifiers can be used in most standard general-purpose operational amplifier applications. Performance as a dc amplifier in a single-power-supply mode is not as precise as a standard integrated-circuit operational amplifier operating from dual supplies. Operation of ...
First Order Transient Response
... Some circuits have multiple stages at which they change states. Sequential switching occurs in a circuit which changes states two or more times at different moments. Solving these circuits require the same methods previously described. The consecutive switches have initial conditions which can be fo ...
... Some circuits have multiple stages at which they change states. Sequential switching occurs in a circuit which changes states two or more times at different moments. Solving these circuits require the same methods previously described. The consecutive switches have initial conditions which can be fo ...
SN65LVDS3486 数据资料 dataSheet 下载
... If the ground noise between the transmitter and receiver is not a concern (less than ±1 V), the answer can be as simple as shown in Figure 14. A resistor divider circuit in front of the LVDS receiver attenuates the 422 differential signal to LVDS levels. The resistors present a total differential lo ...
... If the ground noise between the transmitter and receiver is not a concern (less than ±1 V), the answer can be as simple as shown in Figure 14. A resistor divider circuit in front of the LVDS receiver attenuates the 422 differential signal to LVDS levels. The resistors present a total differential lo ...
GATE EEE 2013 Papers
... Answer: (D) 15. A continuous random variable X has a probability density function x f(x) e ,0 x . Then P{X 1} is (A) 0.368 (B) 0.5 (C) 0.632 (D) 1.0 Answer: (A) 16. The flux density at a point in space is given by 2 x y z B 4xa 2kya 8a Wb /m . The value of constant k must be equal ...
... Answer: (D) 15. A continuous random variable X has a probability density function x f(x) e ,0 x . Then P{X 1} is (A) 0.368 (B) 0.5 (C) 0.632 (D) 1.0 Answer: (A) 16. The flux density at a point in space is given by 2 x y z B 4xa 2kya 8a Wb /m . The value of constant k must be equal ...
SN74S374 数据资料 dataSheet 下载
... functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. Voltage values are with respect to network g ...
... functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. Voltage values are with respect to network g ...
Integrating ADC
An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.