introduction
... STATCOM (Static Compensator) has a characteristic similar to the synchronous condenser, but as an electronic device, it has no inertia and is superior to the synchronous condenser in several ways - better dynamics, a lower investment cost, and lower operating and maintenance costs. STATCOM is to be ...
... STATCOM (Static Compensator) has a characteristic similar to the synchronous condenser, but as an electronic device, it has no inertia and is superior to the synchronous condenser in several ways - better dynamics, a lower investment cost, and lower operating and maintenance costs. STATCOM is to be ...
The Op Amp – Inverting Mode, dc
... 2. In electronics, it is the voltage that is important. Draw voltage time graphs for analogue and digital systems. 3. Draw a block diagram for a public address system. 4. Why do we need an amplifier in the system ? 5. What is the voltage gain of an amplifier ? 6. What is the gain of an amplifier whi ...
... 2. In electronics, it is the voltage that is important. Draw voltage time graphs for analogue and digital systems. 3. Draw a block diagram for a public address system. 4. Why do we need an amplifier in the system ? 5. What is the voltage gain of an amplifier ? 6. What is the gain of an amplifier whi ...
Engineering Presentation
... Unfiltered Inverter Output & Filtered Output Output Filtering Eliminates the chop/step on the output waveform from the Inverter Circuit Ensures the current and voltage waveform stay in-phase for unbalanced loads. ...
... Unfiltered Inverter Output & Filtered Output Output Filtering Eliminates the chop/step on the output waveform from the Inverter Circuit Ensures the current and voltage waveform stay in-phase for unbalanced loads. ...
TI/National LED Lighting Presentation
... • 6V to 42V (LM3406) • 6V to 75V (LM3406HV) • Hysteretic Operation with Controlled On-Time • Up to 1.5A Constant Current Output ...
... • 6V to 42V (LM3406) • 6V to 75V (LM3406HV) • Hysteretic Operation with Controlled On-Time • Up to 1.5A Constant Current Output ...
Design Strategy for a 3-Phase Variable Frequency Drive (VFD)
... These motor drives are designed to be used in conjunction with a 3-phase induction motor. Because these motors typically only have an on/off state of operation, a VFD is needed if multiple operation speeds are desired. Also, apart from selectable speeds, the efficiency of the overall system is incre ...
... These motor drives are designed to be used in conjunction with a 3-phase induction motor. Because these motors typically only have an on/off state of operation, a VFD is needed if multiple operation speeds are desired. Also, apart from selectable speeds, the efficiency of the overall system is incre ...
1A Step-Down Voltage Regulator
... Requiring a minimum number of external components, these regulators are simple to use and include internal frequency compensation and a fixed-frequency oscillator. The LM2575 series offers a high-efficiency replacement for popular three-terminal linear regulators. It substantially reduces the size o ...
... Requiring a minimum number of external components, these regulators are simple to use and include internal frequency compensation and a fixed-frequency oscillator. The LM2575 series offers a high-efficiency replacement for popular three-terminal linear regulators. It substantially reduces the size o ...
DSP BASED POWER ANALYZING SYSTEM FOR ONSITE MEASUREMENTS W.M.S. Wijesinghe and
... The desired objective of a computer-based power analyzing system is to analyze three-phase power systems on site, thus fulfilling an industrial demand. The designed system can be used as a traveling standard with an accuracy of up to 0.05%. Furthermore, the software is more flexible and many referen ...
... The desired objective of a computer-based power analyzing system is to analyze three-phase power systems on site, thus fulfilling an industrial demand. The designed system can be used as a traveling standard with an accuracy of up to 0.05%. Furthermore, the software is more flexible and many referen ...
2938633 Datasheet
... Devices of the same type can be connected in parallel to increase both redundancy and power. The default setting does not have to be adjusted. A maximum of five devices can be connected in parallel. If the output voltage is adjusted, an even current distribution can be ensured by precisely setting a ...
... Devices of the same type can be connected in parallel to increase both redundancy and power. The default setting does not have to be adjusted. A maximum of five devices can be connected in parallel. If the output voltage is adjusted, an even current distribution can be ensured by precisely setting a ...
Noise Interference
... Calculate induced voltage at site of telecommunications plant E = C x L x I x K ...
... Calculate induced voltage at site of telecommunications plant E = C x L x I x K ...
design and construction of a single phase automatic face change
... creates a need for automation of electrical power generation or alternative sources of power to back up the utility supply. This automation is required as the rate of power outage becomes predominantly high. Most industrial and commercial processes are dependent on power supply and if the processes ...
... creates a need for automation of electrical power generation or alternative sources of power to back up the utility supply. This automation is required as the rate of power outage becomes predominantly high. Most industrial and commercial processes are dependent on power supply and if the processes ...
3000 Series Operation Manual
... Refer to Input Voltage Selector in section 2.2. The tolerance is +10% of the indicated voltage at 50/60 Hz. ...
... Refer to Input Voltage Selector in section 2.2. The tolerance is +10% of the indicated voltage at 50/60 Hz. ...
max17552atbevkit - Part Number Search
... tested circuit board that demonstrates the performance of the MAX17552 60V, 100mA ultra-small, high-efficiency, synchronous step-down DC-DC converter in a 10-pin TDFN package. The EV kit operates over a wide input voltage range of 6V to 60V and provides up to 100mA load current at 5V output. It draw ...
... tested circuit board that demonstrates the performance of the MAX17552 60V, 100mA ultra-small, high-efficiency, synchronous step-down DC-DC converter in a 10-pin TDFN package. The EV kit operates over a wide input voltage range of 6V to 60V and provides up to 100mA load current at 5V output. It draw ...
NSC Develops New Complementary Bipolar
... Ft can dramatically decrease at lower voltages on some bipolar process. But Ft's on VIP10 remain high at Vce=1V: 7GHz for the NPN and 5GHz for the PNP. High-speed transistors tend to have poor DC performance, but this is not true for VIP10. Beta and Early voltage are 100 and 120V for the NPN and 55 ...
... Ft can dramatically decrease at lower voltages on some bipolar process. But Ft's on VIP10 remain high at Vce=1V: 7GHz for the NPN and 5GHz for the PNP. High-speed transistors tend to have poor DC performance, but this is not true for VIP10. Beta and Early voltage are 100 and 120V for the NPN and 55 ...
B-TRAN - Ideal Power
... 11) or the EV drive topology shown below (Figure 7 – Ideal Power patent pending). In such topologies, reverse recovery does not occur, and converter performance can be predicted from forward voltage drop and switching losses. Thus it is instructive to compare with other device types using these para ...
... 11) or the EV drive topology shown below (Figure 7 – Ideal Power patent pending). In such topologies, reverse recovery does not occur, and converter performance can be predicted from forward voltage drop and switching losses. Thus it is instructive to compare with other device types using these para ...
Frequently Asked Questions for Other Products
... A: The effect of the SM output stabilizer can be seen directly in the polarization state of the output beam. With stabilization disabled, the stabilizer passes the input light through unchanged; any polarization changes to the input will be seen at the output. With stabilization enabled, the output ...
... A: The effect of the SM output stabilizer can be seen directly in the polarization state of the output beam. With stabilization disabled, the stabilizer passes the input light through unchanged; any polarization changes to the input will be seen at the output. With stabilization enabled, the output ...
BP5061-5
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
2N3906 PZT3906 MMBT3906
... PNP General Purpose Amplifier This device is designed for general purpose amplifier and switching applications at collector currents of 10 µA to 100 mA. Sourced from Process 66. ...
... PNP General Purpose Amplifier This device is designed for general purpose amplifier and switching applications at collector currents of 10 µA to 100 mA. Sourced from Process 66. ...
TRANSDUCER CONDITIONING INTERFACE output of this unit provides a direct
... channel. It has been developed with technical and functional features particularly suitable to convert a position measurement in a signal compatible with most of the analog cards for data acquisition. The ...
... channel. It has been developed with technical and functional features particularly suitable to convert a position measurement in a signal compatible with most of the analog cards for data acquisition. The ...
Variable-frequency drive
A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.