ENERGY LABORATORY
... Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module is for 20 students post, but we can recommend the number of units for 30 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation ...
... Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module is for 20 students post, but we can recommend the number of units for 30 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation ...
MAX6315 Open-Drain SOT µP Reset Circuit ________________General Description ____________________________Features
... open-drain output to level-shift from the monitored supply to reset circuitry powered by some other supply (Figure 1). This is one useful feature of an open-drain output. Keep in mind that as the MAX6315’s V CC decreases below 1V, so does the IC’s ability to sink current at RESET. Finally, with any ...
... open-drain output to level-shift from the monitored supply to reset circuitry powered by some other supply (Figure 1). This is one useful feature of an open-drain output. Keep in mind that as the MAX6315’s V CC decreases below 1V, so does the IC’s ability to sink current at RESET. Finally, with any ...
MAX9312/MAX9314 Dual 1:5 Differential LVPECL/LVECL/HSTL Clock and Data Drivers General Description
... The MAX9312/MAX9314 are low-skew, dual 1-to-5 differential drivers designed for clock and data distribution. For interfacing to differential HSTL and LVPECL signals, these devices operate over a +2.25V to +3.8V supply range, allowing high-performance clock or data distribution in systems with a nomi ...
... The MAX9312/MAX9314 are low-skew, dual 1-to-5 differential drivers designed for clock and data distribution. For interfacing to differential HSTL and LVPECL signals, these devices operate over a +2.25V to +3.8V supply range, allowing high-performance clock or data distribution in systems with a nomi ...
Chapter 3: Data Converter Architectures
... Kelvin divider or string DAC as shown in Figure 3.4. An N-bit version of this DAC simply consists of 2N equal resistors in series and 2N switches (usually CMOS), one between each node of the chain and the output. The output is taken from the appropriate tap by closing just one of the switches (there ...
... Kelvin divider or string DAC as shown in Figure 3.4. An N-bit version of this DAC simply consists of 2N equal resistors in series and 2N switches (usually CMOS), one between each node of the chain and the output. The output is taken from the appropriate tap by closing just one of the switches (there ...
NEM Interconnection Handbook
... If the components change from design to Failure to comply with these requirements will result installation, submit revised documents with in potential delay, and any corrections required to subject line ‘EQUIP CHANGE’ prior to bring the project into compliance with these scheduling the final inspect ...
... If the components change from design to Failure to comply with these requirements will result installation, submit revised documents with in potential delay, and any corrections required to subject line ‘EQUIP CHANGE’ prior to bring the project into compliance with these scheduling the final inspect ...
WECC-0107 Posting 9 VAR-501-WECC
... Requirement simplifies the process by allowing the Generator Operator to communicate to the Transmission Operator the circumstances that render the PSS unavailable to the Transmission Operator (such as component failure, maintenance, and testing). Requirement R3 Nothing in this RSS should be constru ...
... Requirement simplifies the process by allowing the Generator Operator to communicate to the Transmission Operator the circumstances that render the PSS unavailable to the Transmission Operator (such as component failure, maintenance, and testing). Requirement R3 Nothing in this RSS should be constru ...
Diagnostic Repair Manual - Generator
... Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6 C (10 F) above 16 C (60 F) ambient temperature. ** Load current values shown for 120 volts are maximum TOTAL values for two separate circuits. The maximum current in each ...
... Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6 C (10 F) above 16 C (60 F) ambient temperature. ** Load current values shown for 120 volts are maximum TOTAL values for two separate circuits. The maximum current in each ...
Problem Statement Background
... Modulation of HVdc or SVC via supplementary controls such as angle damping or frequency damping applied to damp local or inter-area oscillations ...
... Modulation of HVdc or SVC via supplementary controls such as angle damping or frequency damping applied to damp local or inter-area oscillations ...
MAX9322 LVECL/LVPECL 1:15 Differential Divide-by-1/Divide-by-2 Clock Driver General Description
... the lower of (VCC - VEE ) and 3V. Typical values are at (VCC - VEE) = 3.3V, VIHD = VCC - 1V, VILD = VCC - 1.5V.) (Notes 1–4) ...
... the lower of (VCC - VEE ) and 3V. Typical values are at (VCC - VEE) = 3.3V, VIHD = VCC - 1V, VILD = VCC - 1.5V.) (Notes 1–4) ...
220 W LCD TV Power Supply GreenPoint® Reference Design
... The SMPS stage uses a Half Bridge Resonant LLC topology. This topology offers a number of advantages as demonstrated in the schematics and the results. It improves efficiency, reduces EMI signature and provides better magnetic utilization. The NCP1395 controller and NCP5181 driver are used to implem ...
... The SMPS stage uses a Half Bridge Resonant LLC topology. This topology offers a number of advantages as demonstrated in the schematics and the results. It improves efficiency, reduces EMI signature and provides better magnetic utilization. The NCP1395 controller and NCP5181 driver are used to implem ...
gesis ELECTRONIC - Wieland Electric Inc.
... internal bus contact automatically when the modules are combined. In-between feed-in modules allow separate fuses for different functions. Because of the flat shape, the connection from one side, well-thought-out mounting options and the modular concept of this system fits in almost any space. The s ...
... internal bus contact automatically when the modules are combined. In-between feed-in modules allow separate fuses for different functions. Because of the flat shape, the connection from one side, well-thought-out mounting options and the modular concept of this system fits in almost any space. The s ...
Electronics 123
... Shop1 Moulton Centre, Cnr. of Codonia & Moulton Street, Waverley, Pretoria, South Africa PO Box 31113 Waverley Pretoria 0135, Tel: (012) 332 2356, Fax: (012) 332 0487 E-mail: [email protected], Internet: http://www.electronics123.co.za Dear Electronics Enthusiast ...
... Shop1 Moulton Centre, Cnr. of Codonia & Moulton Street, Waverley, Pretoria, South Africa PO Box 31113 Waverley Pretoria 0135, Tel: (012) 332 2356, Fax: (012) 332 0487 E-mail: [email protected], Internet: http://www.electronics123.co.za Dear Electronics Enthusiast ...
SW Series Inverter/Chargers Owner`s Manual
... to ensure that your inverter/charger is properly packaged for shipping including the following: ...
... to ensure that your inverter/charger is properly packaged for shipping including the following: ...
Power Supplies - Peat Wholesale
... inverters use a pure sine wave to power mains equipment from either 12 or 24V battery. • Pure sine wave output • Soft start (Minimises inverter shutdown when using large inductive loads) • Reverse polarity protection • Short circuit and overload protection • Battery low/high shutdown • Over temperat ...
... inverters use a pure sine wave to power mains equipment from either 12 or 24V battery. • Pure sine wave output • Soft start (Minimises inverter shutdown when using large inductive loads) • Reverse polarity protection • Short circuit and overload protection • Battery low/high shutdown • Over temperat ...
Mechatronics and Manufacturing Automation NPTEL
... Using computer aided design (CAD) / computer aided analysis (CAE) tools, threedimensional models of products can easily be developed. These models can then be analyzed and can be simulated to study their performances using numerical tools. These numerical tools are being continuously updated or enri ...
... Using computer aided design (CAD) / computer aided analysis (CAE) tools, threedimensional models of products can easily be developed. These models can then be analyzed and can be simulated to study their performances using numerical tools. These numerical tools are being continuously updated or enri ...
Variable-frequency drive
A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.