• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
WEEK 5 sizing 1(2)
WEEK 5 sizing 1(2)

... a maximum voltage drop of 5% between the solar array and the inverter. If the inverter is located far from the point of connection to the grid then the AC voltage drop is also need to be included in this 5% 5.4.5 Inverter efficiency - There are losses in the inverter due to transformer losses, power ...
Distribution of Voltage Fluctuations in a Current-Biased Conductor M. Kindermann, Yu.V. Nazarov,
Distribution of Voltage Fluctuations in a Current-Biased Conductor M. Kindermann, Yu.V. Nazarov,

... (with T the temperature) sets the width of current pulses associated with the transfer of individual electrons. The second time scale 2  e=I sets the spacing of the pulses. Let ! be the characteristic frequency of a particular realization of the fluctuating phase. For the low-frequency approximati ...
A/D successive approximation converter.
A/D successive approximation converter.

Q4806123132
Q4806123132

... comparison of the circuit can be determined accurately. The input, output voltages, current and power is the main comparisons to take in to the consideration. The complexity and simplicity of the circuit have been determined based on the literature. For checking the robustness of the converters a st ...
BH4301327332
BH4301327332

... advantages over all of these converters. Mainly they can improve the efficiency and the simplification of the circuitry needed. A KY buck–boost converter has been introduced to conquer the mentioned drawbacks of the system. A common buck converter with KY boost converter, it has a serious problem in ...
switching voltage regulator and variable current limiter
switching voltage regulator and variable current limiter

PDF from Jabsco
PDF from Jabsco

... the switch. Ensure the panel where installing switch is no more than 1" thick. Drill a 5/8" mounting hole and install switch and instruction plate. Use stranded copper wire of the correct size (determined from the electrical specifications chart) to connect one side of the switch to the positive pow ...
EN 1724852
EN 1724852

... showing on the output for positive interval of clocked the logic is generating and for the negative interval it produces zero output. The above logic is valid only when the amplitude of input signal starts from zero and reaches toward the maximum value as the amplitude falls from the maximum value t ...
AN-1992 LM27402 Evaluation Board (Rev. B)
AN-1992 LM27402 Evaluation Board (Rev. B)

Technical information for micro switches
Technical information for micro switches

... possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. In terms of the systems involved, make provision for redundancy in the design and take steps to achieve safety design. 2) The ambient operating temperature (and hu ...
DS1088C Fixed-Frequency EconoOscillator™ General Description Features
DS1088C Fixed-Frequency EconoOscillator™ General Description Features

... by1000hr (max) VCC biased +125°C OP/L, 1000hr unbiased +150°C bake, 1000 temperature cycles at -55°C to +125°C and 168hr +121°C/2 ATM steam/unbiased autoclave. Note 3: This is the change in output frequency due to changes in voltage at TA = +25°C. Note 4: Guaranteed by design. Note 5: This is the ...
FREQUENCY RESPONSE ANALYZERS
FREQUENCY RESPONSE ANALYZERS

... High density measurements of up to 20,000 points at one sweep are possible. Logarithmic equal interval setting and auto-magnification in sections where values greatly change are possible. Resolution is 0.1mHz. ...
ICT Modular Power Series_Data Sheet_800-340-000
ICT Modular Power Series_Data Sheet_800-340-000

... charging, display of battery voltage, status, battery current, state of charge, run time remaining; adjust LVD settings; ...
Detection of selected EMI Sources in the Prototype of LED Street Light
Detection of selected EMI Sources in the Prototype of LED Street Light

... satisfactory EMC, a well-designed electric equipment with installation can extend the compatibility safety margins. Moreover, it must also be noted that only measurements requiring a high level of expertise and sophisticated equipment can produce valid results quantifying the EMC of equipment. Curre ...
3B42 数据手册DataSheet 下载
3B42 数据手册DataSheet 下载

... readily hot-swapped under full power and interchanged without disrupting field wiring. The Analog Devices 3B Series Signal Conditioning Subsystem is designed to easily handle signal conditioning problems in measurement and control applications. Some typical uses are in microcomputer-based data acqui ...
Compensating for Varying Material Conditions in Resistance Welding
Compensating for Varying Material Conditions in Resistance Welding

... constant voltage feedback modes are limited in their ability to cope with varying levels of plating and oxides. When constant current is used on heavily oxidized parts, the power supply ramps the voltage to very high levels in order to achieve the initial current flow. The rapid input of current, al ...
student learning outcome guide - System Operations
student learning outcome guide - System Operations

... Explain why an accident happened and how adherence to the CFR would have prevented the accident given a list of some of the most frequently cited serious violations, and give the specific CFR section related to each accident. ...
Penang Branch
Penang Branch

... Nottingham, UK in 1989. From 1973 to 1998, he was with the Electrical Engineering Department of the Ungku Omar Polytechnic, Ipoh, Malaysia. In September 2004, he joined the MARA University of Technology, Penang, Malaysia (UiTM) where he is currently a Senior Lecturer in the Department of Electrical ...
Optimal Sizing and Placement of Battery Energy
Optimal Sizing and Placement of Battery Energy

... overvoltage issue is the deployment of energy storage systems [8]. Among all feasible types of energy storage technologies, a battery based energy storage system can be considered as widely used and fairly developed. As a result, batteries in the form of battery energy storage systems (BESS) and its ...
16-bit stereo D / A converter for audio applications
16-bit stereo D / A converter for audio applications

3 CHAPTER EXPERIMENTAL FAN  BLADE DAMAGE SIMULATOR
3 CHAPTER EXPERIMENTAL FAN BLADE DAMAGE SIMULATOR

... 3.3 Manufactured fan blade damage simulator As mentioned earlier in this chapter, the decision to install the EFBDS in an easily accessible location limited the power supply to single phase 220 V. While DC motors with a 1.5 kW rating do exist and excellent speed control can be applied to the motors ...
Galvanically Isolated Modular Converter - Infoscience
Galvanically Isolated Modular Converter - Infoscience

AL9910-5 - Diodes Incorporated
AL9910-5 - Diodes Incorporated

... MOSFET Q1 is turned off. The stored energy in the inductor causes the current to continue to flow through the LEDs via diode D1. The AL9910’s LDO provides all power to the rest of the IC including Gate drive this removes the need for large high power start-up resistors. This means that operate corre ...
Circuit Note CN-0130
Circuit Note CN-0130

... 25 mA) is powered from AVDD/AVSS; the medium current range, named EXT2, is powered from HCAVDD2/HCAVSS2; the high current range, named EXT1, is powered from HCAVDD1/HCAVSS1. The HC supplies should always be equal to or less than the AVDD/AVSS rails. The purpose of the HC rails is to allow the user t ...
TGA4539-SM 数据资料DataSheet下载
TGA4539-SM 数据资料DataSheet下载

... RF performance of the TGA4539-SM is optimum when placed in the impedance environment specified below. These impedances are NOT the impedances of the device; they are the impedances presented to the device via an RF circuit or load pull system. ZLOAD is the load impedance presented at pin 13. For loa ...
< 1 ... 655 656 657 658 659 660 661 662 663 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report