• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
GIGAVAC HXNC241 Normally Closed EPIC DC Contactor
GIGAVAC HXNC241 Normally Closed EPIC DC Contactor

... 4 Contactor has two coils. Both are used for pick-up, and then in approximately 75 milliseconds, one coil is electronically removed from the coil drive circuit. The remaining coil supplies low continuous hold power sufficient for the contactor to meet all of its specified performance specifications. ...
Switching Diode Frequency Doublers
Switching Diode Frequency Doublers

... potential. Hybrid versions are available with a pn guard ring which enhances the breakdown voltage but increases the junction capacitance to more than 1 pf. A common part is the 1N5711 which has a breakdown voltage of 70 volts and a junction capacity of 2 pf maximum. Passivated diodes constructed wi ...
Kostakis-etal-EST2017-Fast-acting-protection-as-a-key-enabler
Kostakis-etal-EST2017-Fast-acting-protection-as-a-key-enabler

... The More-Electric concept for aircraft has been a technological shift in the aviation industry that progressively replaces mechanical, pneumatic and hydraulic systems with their electrical equivalents. Civil-aircraft manufacturers have identified that these ‘More-Electric’ technologies can help redu ...
DAC7621 数据资料 dataSheet 下载
DAC7621 数据资料 dataSheet 下载

... device. Bipolar transistors are used where tight matching and low noise are needed to achieve analog accuracy, and CMOS transistors are used for logic, switching functions and for other low power stages. If power consumption is critical, it is important to keep the logic levels on the digital inputs ...
Aalborg Universitet Investigation of Flux-Linkage Profile Measurement Methods for Switched-Reluctance
Aalborg Universitet Investigation of Flux-Linkage Profile Measurement Methods for Switched-Reluctance

ENHANCED CONTROL OF A DFIG-BASED WIND
ENHANCED CONTROL OF A DFIG-BASED WIND

... There is a controller in the nacelle and one at the base of the turbine. The controller monitors the condition of the turbine and controls the turbine movement. Different types of controllers used are: a) Pitch Angle Control: This system changes the pitch angle of the blades according to the variati ...
High-Efficiency, 3A, Current-Mode Synchronous, Step-Down Switching Regulator MAX15058 General Description Features
High-Efficiency, 3A, Current-Mode Synchronous, Step-Down Switching Regulator MAX15058 General Description Features

... The MAX15058 features a 1MHz, factory-trimmed, fixedfrequency PWM mode operation. The high switching frequency, along with the PWM current-mode architecture, allows for a compact, all-ceramic capacitor design. The MAX15058 offers a capacitor-programmable softstart reducing inrush current, startup in ...
LTZ1000/LTZ1000A - Ultra Precision Reference
LTZ1000/LTZ1000A - Ultra Precision Reference

... while tin oxide type resistors have very high thermocouple voltage. Film resistors, especially Vishay precision film resistors, can have low thermocouple voltage. Ordinary breadboarding techniques are not good enough to give stable output voltage with the LTZ1000 family devices. For breadboarding, i ...
MAX2686/MAX2688 GPS/GNSS Low-Noise Amplifiers General Description Features
MAX2686/MAX2688 GPS/GNSS Low-Noise Amplifiers General Description Features

Aalborg Universitet Generator Units with Droop Control and Virtual Impedance Loop
Aalborg Universitet Generator Units with Droop Control and Virtual Impedance Loop

... II. MODELING OF THE PROPOSED POWER FLOW ANALYSIS When the line impedance is inductive enough (e.g. R/X≈0.31 as mentioned in [10]), either because of long transmission distance or the large output inductor of the output filter, specially here when an LCL filter or transformer are used at the output o ...
Built-in the Phase adjustment control and 180°energizing drive Three Phase Motor Predriver Datasheet
Built-in the Phase adjustment control and 180°energizing drive Three Phase Motor Predriver Datasheet

... OSC (triangular wave) and the voltage proportional to torque are compared by 2.5V standard. Figure-5 becomes the torque output voltages and shape of waves of triangular wave when VTH=2.5V is input. The amplitude of the torque output voltage compared with a triangular wave changes when VTH is changed ...
DISCONTINUED PRODUCT - Allegro Microsystems
DISCONTINUED PRODUCT - Allegro Microsystems

... device. The state-of-the-art technology provides the same output polarity for either pole face. It is strongly recommended that an external bypass capacitor be connected (in close proximity to the Hall element) between the supply and ground of the device to reduce both external noise and noise gener ...
AN2454
AN2454

... This document describes how to design a 3-phase power supply with the UC3845B PWM driver and the new STC04IE170 ESBT as main switch. It is associated with the release of the STEVAL-IPB001V1 demo board (see figure below). The design is a complete solution for the 2 W single output SMPS, which is wide ...
909KB PDF - Contrex Inc
909KB PDF - Contrex Inc

... SINE/RESOLVER MODE - In this mode of operation, a brushless motor with an integral resolver is required. The personality module contains a resolver to digital converter which provides the positional information to the amplifier that is required to commutate the motor. This positional information is ...
Conventional DC Machines and Universal Motor - Lab-Volt
Conventional DC Machines and Universal Motor - Lab-Volt

... geographically to use at the purchaser's site/location as follows. The purchaser shall be entitled to use the work to train his/her staff at the purchaser's site/location and shall also be entitled to use parts of the copyright material as the basis for the production of his/her own training documen ...
N14 TYPE USER`S MANUAL
N14 TYPE USER`S MANUAL

... active, reactive and apparent power, active and reactive energy, power factors, frequency, mean active power (e.g. 15-min mean power). Voltages and currents are multiplied by given current and voltage ratios of measuring transformers. Indications of power and energy take into consideration programme ...
Implementing a Battery Energy Storage System with a Converterless
Implementing a Battery Energy Storage System with a Converterless

Current Mode Interconnect - Department of Electrical Engineering
Current Mode Interconnect - Department of Electrical Engineering

Data Sheet
Data Sheet

MX60 Manual Rev 3.qxd
MX60 Manual Rev 3.qxd

... The large terminal block in the center is for PV+, PV-, BAT- and BAT+. The aluminum terminal on the right side of the chassis is the equipment ground. The equipment-grounding terminal can mounted on the outside of the enclosure if desired, although normally the equipment-grounding conductors will be ...
Source Transformations
Source Transformations

...  Removing the load Rp parallel to the CVS has no impact on externally connected loads RL  Such loads RL—not drawn here— will be in series with resistor R  Removal of Rp decreases the amount of current that the CVS has to produce, to deliver equal voltage to both Rp and the series of R and load RL ...
GE PIM400 Series; ATCA Board Power Input Modules Data Sheet
GE PIM400 Series; ATCA Board Power Input Modules Data Sheet

... Based on the information provided in this data sheet on inrush current and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. ...
Braking Systems - Faculty Of Engineering And Technology
Braking Systems - Faculty Of Engineering And Technology

R225-10-1
R225-10-1

... REACTANCE at 60-cycle in ohms per 1000 feet of each conductor of a single-phase circuit or of a three-phase circuit with symmetrical triangular spacing. For other arrangements of conductors, see Note. Reactance values are for concentric stranded copper conductors and are approximately correct for al ...
NTE4018B Integrated Circuit CMOS, Presettable Divide−By−N
NTE4018B Integrated Circuit CMOS, Presettable Divide−By−N

... The NTE4002B contains five Johnson counter stages which are asynchronously presettable and resettable. The counters are synchronous, and increment on the positive going edge of the clock. Presetting is accomplished by a logic “1” on the preset enable input. Data on the Jam inputs will then be transf ...
< 1 ... 562 563 564 565 566 567 568 569 570 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report