
MAX1820/MAX1821 WCDMA Cellular Phone 600mA Buck Regulators General Description
... Buck Regulators (VBATT = 3.6V, SHDN = BATT, SKIP = SYNC = GND, VREF = 1.25V (MAX1820 only), TA = 0°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.) (Note 2) ...
... Buck Regulators (VBATT = 3.6V, SHDN = BATT, SKIP = SYNC = GND, VREF = 1.25V (MAX1820 only), TA = 0°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.) (Note 2) ...
DS4M125/DS4M133/DS4M200 3.3V Margining Clock Oscillator with LVPECL/LVDS Output General Description
... an AT-cut fundamental-mode crystal to form a complete clock oscillator. The circuit can generate the following frequencies and their ±5% frequency deviations: 125MHz, 133.33MHz, and 200MHz. The DS4M125/ DS4M133/DS4M200 employ a low-jitter PLL to generate the frequencies. The typical phase jitter is ...
... an AT-cut fundamental-mode crystal to form a complete clock oscillator. The circuit can generate the following frequencies and their ±5% frequency deviations: 125MHz, 133.33MHz, and 200MHz. The DS4M125/ DS4M133/DS4M200 employ a low-jitter PLL to generate the frequencies. The typical phase jitter is ...
APL Subwoofer Manual
... then calculate a safety margin of 25% or greater. If special length AC cables are required for your powered speakers, they should be constructed of durable, high-quality portable cordage such as S, SO, or SJO type. Chart 2 provides the basic guidelines of The National Electric Code for four common g ...
... then calculate a safety margin of 25% or greater. If special length AC cables are required for your powered speakers, they should be constructed of durable, high-quality portable cordage such as S, SO, or SJO type. Chart 2 provides the basic guidelines of The National Electric Code for four common g ...
A+ Practice Questions
... 71- It is most important to keep hard drives and diskettes away from? (choose two) a) Telephones b) Battery-operated devices c) Magnetic devices d) Temperature extremes 72- _________ help prevent power surges. a) Surge suppressor b) Spike protector c) UPS system d) High-grade multi-meter 73- What de ...
... 71- It is most important to keep hard drives and diskettes away from? (choose two) a) Telephones b) Battery-operated devices c) Magnetic devices d) Temperature extremes 72- _________ help prevent power surges. a) Surge suppressor b) Spike protector c) UPS system d) High-grade multi-meter 73- What de ...
MP20075 - Monolithic Power System
... High−current traces are the trace from the input voltage terminal to VDDQ pin, the trace from the VTT output terminal to the load, the trace from the input ground terminal to the VTT output ground terminal, and the trace from VTT output ground terminal to the GND pin. Power handling and heaksinking ...
... High−current traces are the trace from the input voltage terminal to VDDQ pin, the trace from the VTT output terminal to the load, the trace from the input ground terminal to the VTT output ground terminal, and the trace from VTT output ground terminal to the GND pin. Power handling and heaksinking ...
PM150/PM240 Installation manual
... are not necessary. 1. Connect protective earth to the connection marked no 40. Use a ring terminal that has been crimped by an appropriate tool. 2. Connect the output. The converter output is short-circuit proof by a constant current limit which works unlimited in time. Therefore there is no need to ...
... are not necessary. 1. Connect protective earth to the connection marked no 40. Use a ring terminal that has been crimped by an appropriate tool. 2. Connect the output. The converter output is short-circuit proof by a constant current limit which works unlimited in time. Therefore there is no need to ...
125-µA Standby, High-Efficiency Power Supply
... terminal. The UL773A does allow it with certain restrictions and one of the important requirements is that the current flowing through the ground should be limited to 0.5 mA. This is to ensure that the ground current does not exceed the trip limit of the earth leakage circuit breaker, which may be t ...
... terminal. The UL773A does allow it with certain restrictions and one of the important requirements is that the current flowing through the ground should be limited to 0.5 mA. This is to ensure that the ground current does not exceed the trip limit of the earth leakage circuit breaker, which may be t ...
Electronic ballasts (EB) Technical Details - Vossloh
... The operation of a fluorescent lamp depends on a ballast that stabilises the lamp's preheat current after connection to the mains and, in conjunction with the starter, also supplies the required lamp ignition voltage after preheating. After ignition, the ballast then serves to limit the lamp current ...
... The operation of a fluorescent lamp depends on a ballast that stabilises the lamp's preheat current after connection to the mains and, in conjunction with the starter, also supplies the required lamp ignition voltage after preheating. After ignition, the ballast then serves to limit the lamp current ...
S. Lim, D.M. Otten and D.J. Perreault, “Power Conversion Architecture for Grid Interface at High Switching Frequency,” 2014 IEEE Applied Power Electronics Conference , pp. 854-861, March 2014.
... system described in the following section. The stack capacitors are picked as C1 = 1µF and C2 = 50µF . In addition, each regulating converter is assumed to be able to operate across a 35–100 V input voltage range and to be able to deliver power unidirectionally from its input to the power combining ...
... system described in the following section. The stack capacitors are picked as C1 = 1µF and C2 = 50µF . In addition, each regulating converter is assumed to be able to operate across a 35–100 V input voltage range and to be able to deliver power unidirectionally from its input to the power combining ...
Introduction to Solid State Electronics_independent_study
... electron not being attached to any particular atom and thus can move around as a free electron. These free electrons support the flow of electrical current through the doped semiconductor material. The number of free electrons depends on the amount of impurity added. If a large amount of Phosphorous ...
... electron not being attached to any particular atom and thus can move around as a free electron. These free electrons support the flow of electrical current through the doped semiconductor material. The number of free electrons depends on the amount of impurity added. If a large amount of Phosphorous ...
Lock-In Specification - Crucial Power Products
... on/off sensor, power supply sensor, etc. to prevent harm to the UPS caused by user error. Accepts wide input range: The UPS shall accept wide input range, so that it can work effectively under an unstable AC source. All of the input components used are specifically selected to handle extreme high ...
... on/off sensor, power supply sensor, etc. to prevent harm to the UPS caused by user error. Accepts wide input range: The UPS shall accept wide input range, so that it can work effectively under an unstable AC source. All of the input components used are specifically selected to handle extreme high ...
TS-21 "Hellfire Modulator" owner`s manual
... The controls on the RIGHT of the TS-21 panel deal with the beam modulator. BEAM SCREEN--controls the screen-grid voltage to the beam modulator tube. Turn it fully counterclockwise and the tube is fully cut off, with no signal reaching the output. Turn it to the 12-o'clock position to fully turn the ...
... The controls on the RIGHT of the TS-21 panel deal with the beam modulator. BEAM SCREEN--controls the screen-grid voltage to the beam modulator tube. Turn it fully counterclockwise and the tube is fully cut off, with no signal reaching the output. Turn it to the 12-o'clock position to fully turn the ...
M81713FP HVIC High Voltage Half-Bridge Driver 600V +/
... HO outputs “L” level as long as UV error for VCC is detected. LO is locked at “L” as long as UV error for VCC is detected. (VCC)* HO responds to IN if VCC exceeds VCC UV reset level. After VCC exceeds VCC UV reset level, the lock for LO is removed and responds to IN signal. ...
... HO outputs “L” level as long as UV error for VCC is detected. LO is locked at “L” as long as UV error for VCC is detected. (VCC)* HO responds to IN if VCC exceeds VCC UV reset level. After VCC exceeds VCC UV reset level, the lock for LO is removed and responds to IN signal. ...
LTC1069-1 - Low Power, 8th Order Progressive Elliptic, Lowpass Filter
... CLK (Pin 5): Clock Input Pin. Any TTL or CMOS clock source with a square wave output and 50% duty cycle (±10%) is an adequate clock source for the device. The power supply for the clock source should not necessarily be the filter’s power supply. The analog ground of the filter should be connected to c ...
... CLK (Pin 5): Clock Input Pin. Any TTL or CMOS clock source with a square wave output and 50% duty cycle (±10%) is an adequate clock source for the device. The power supply for the clock source should not necessarily be the filter’s power supply. The analog ground of the filter should be connected to c ...
mic+600/IU/TC
... In the add-on-menu of TouchControl, the user can, however, also pre-set the sensor to current or voltage output. In this menu, the measuring value output on the LED display with analogue sensors can additionally be changed to percentage indication. The window limits of the analogue characteristic ...
... In the add-on-menu of TouchControl, the user can, however, also pre-set the sensor to current or voltage output. In this menu, the measuring value output on the LED display with analogue sensors can additionally be changed to percentage indication. The window limits of the analogue characteristic ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.