• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
™ High-Performance, Bipolar-Input AUDIO OPERATIONAL AMPLIFIERS OPA1602
™ High-Performance, Bipolar-Input AUDIO OPERATIONAL AMPLIFIERS OPA1602

... signal current is not inherently limited, an input series resistor (RI) and/or a feedback resistor (RF) can be used to limit the signal input current. This resistor degrades the low-noise performance of the OPA160x and is examined in the following Noise Performance section. Figure 32 shows an exampl ...
DC-DC Converter Applications - RS Components International
DC-DC Converter Applications - RS Components International

... interpretation. Also we have reduced the number of environments from 14 to 6, which are most appropriate to commercial applications. For a more detailed understanding of the environments quoted and the hybrid model, it is recommended that a full copy of MIL-HDBK-217F is obtained. It is interesting t ...
Basic Wiring for Motor Contol
Basic Wiring for Motor Contol

... Separate voltages supplied by different voltage sources. How can you have two different voltages going into the same starter? One method is to run different wires from different electrical voltage sources. You might have a 480V supply that is attached to the line side of the starter, and that runs t ...
ADS8324 数据资料 dataSheet 下载
ADS8324 数据资料 dataSheet 下载

... The ADS8324 is a 14-bit, sampling Analog-to-Digital (A/D) converter with tested specifications using a 1.8V supply voltage. It requires very little power, even when operating at the full 50kHz data rate. At lower data rates, the high speed of the device enables it to spend most of its time in the po ...
AL9910/ AL9910A/ AL9910-5/ AL9910A-5 Description Pin Assignments
AL9910/ AL9910A/ AL9910-5/ AL9910A-5 Description Pin Assignments

... MOSFET Q1 is turned off. The stored energy in the inductor causes the current to continue to flow through the LEDs via diode D1. The AL9910’s LDO provides all power to the rest of the IC including Gate drive this removes the need for large high power start-up resistors. This means that operate corre ...
Reversible Current Power Supply for Fast-Field
Reversible Current Power Supply for Fast-Field

... Starting with the Middle and High Stages, which have the same behavior, in terms of active switches, the processes can be described as: Middle/High Stage In this stage, S1 switch alternately, to maintain the magnet current ate the desirable level, with the help of the capacitor C0, which charges and ...
Aalborg Universitet An Analysis of Modified Demodulation-Based Grid Voltage Parameter Estimator
Aalborg Universitet An Analysis of Modified Demodulation-Based Grid Voltage Parameter Estimator

... of microgrids, control of grid-connected power converters and monitoring and protection of power systems [1]-[3]. Different approaches have been proposed in the literature to estimate the fundamental parameters of the grid voltage. The zero-crossing detection (ZCD) based method is probably the simpl ...
datasheet - Texas Instruments
datasheet - Texas Instruments

... It sets the switching frequency, which is constant for steady state operating conditions, and provides immediate response to dynamic load changes. To get accurate DC load regulation, a voltage feedback loop is used. The internally compensated regulation network achieves fast and stable operation wit ...
Motors and Generators
Motors and Generators

... The electromagnetic brakes consist of electromagnets positioned on either side of a rotating disc. The electromagnets will be creating a magnetic field as a result of the current flowing through them; and as a result of Len's Law, the spinning disc (nonmagnetic) will interact with this magnetic fie ...
User manual 1
User manual 1

... BDAT and LDAT must contain the same data needed for fault studies. In addition, BDAT must contain the characteristics of any connected nonlinear loads. ...
Guide to Successful Dual Voltage Systems
Guide to Successful Dual Voltage Systems

... with "Ignition" inputs, used to turn the unit "on" and "off", so that when the key switch is turned off, the converter output drops to zero. In batteryless installation, the converter must be capable of supplying all of the current to the load. This applies to peak currents, even if they are only fo ...
Exam Solutions
Exam Solutions

... (21 pts) Z-bus: A three-bus network is operating so that all buses have voltage magnitudes equal to 1.0 pu. Each bus is connected to the other two buses via branches having impedance of j0.1 pu. The Z-bus of the network is given as: ...
MAX1722/MAX1723/ MAX1724 1.5µA I , Step-Up DC-DC Converters in TSOT
MAX1722/MAX1723/ MAX1724 1.5µA I , Step-Up DC-DC Converters in TSOT

... Inductor Selection The control scheme of the MAX1722/MAX1723/ MAX1724 permits flexibility in choosing an inductor. A 10µH inductor value performs well in most applications. Smaller inductance values typically offer smaller physical size for a given series resistance, allowing the smallest overall ci ...
BD8184MUV
BD8184MUV

... the sufficient margin so that these two values are within the standard value range. (3) Selecting the Input Capacitor Since the peak current flows between the input and output at the DC/DC converter, a capacitor is required to install at the input side. For the reason, the low ESR capacitor is recom ...
PDF
PDF

... Prepared by ...
SECTION 16210
SECTION 16210

FEATURES DESCRIPTION D
FEATURES DESCRIPTION D

... properly but with unspecified offset voltage. This design has virtually no aliasing and very low noise. Zero correction occurs at a 10kHz rate, but there is very little fundamental noise energy present at that frequency due to internal filtering. For all practical purposes, any glitches have energy ...
MAX17597 Evaluation Kit Evaluates: MAX17597 in a Step-Up (Boost) Configuration General Description
MAX17597 Evaluation Kit Evaluates: MAX17597 in a Step-Up (Boost) Configuration General Description

AS1341
AS1341

... The AS1341 uses a proprietary current-limiting control scheme with operation up to 100% duty cycle. The DC-DC converter pulses as needed to maintain regulation, resulting in a variable switching frequency that increases with the load. This eliminates the high-supply currents associated with conventi ...
LF147 数据资料 dataSheet 下载
LF147 数据资料 dataSheet 下载

... capacitor should be such that the RC time constant of this capacitor and the resistance it parallels is greater than or equal to the original feedback pole time constant. ...
ETSO-C174
ETSO-C174

... (breakdown) of voltage of such separation devices will exceed three times the BEPU rated voltage. (p) The maximum output voltage ripple cannot exceed the limits stated in MILSTD-704F. Note this limit does not include the ripple already on the input line into the BEPU. (See Figure A-3 at the end of t ...
MTD5P06V 5V - Red Rock Energy
MTD5P06V 5V - Red Rock Energy

... SOURCE−DRAIN DIODE CHARACTERISTICS Forward On−Voltage ...
70 W HID lamp ballast based on the L6569, L6385E and L6562A
70 W HID lamp ballast based on the L6569, L6385E and L6562A

... Constant power control circuit In this solution, the voltage on pin 3 of U2 (L6562A) is fixed, therefore, during the warmup time, pin 2 of U2 is clamped at its upper threshold, so the input peak current detected by pin 4 is also fixed. Once the lamp power increases with the lamp voltage increase, pi ...
MAX9989/MAX9990 +14dBm to +20dBm LO Buffers with ±1dB Variation General Description
MAX9989/MAX9990 +14dBm to +20dBm LO Buffers with ±1dB Variation General Description

... for the amplifiers are adjustable through off-chip resistors, allowing the output level to be precision set anywhere from +14dBm to +20dBm. The PLL output is preset to +3dBm (about 900mVP-P into 50Ω). Power levels are typically ±1dB over the full supply, input power, and temperature range. Precision ...
S280-77-8
S280-77-8

... transformers and has negligible effects on the Form 4C control. The input current is fed through another current transformer whose secondary is connected across a resistance to establish an ac voltage proportional to line current. This voltage is then full-wave rectified by a set of Schottky diodes ...
< 1 ... 542 543 544 545 546 547 548 549 550 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report