
MetraBus User`s Manual - Measurement Computing
... MetraBus cable then connects the driver board to one or more I/O boards. The cable can be up to 100 feet long, allowing the host computer and driver board to reside in a controlled environment. The I/O boards can be located remotely near the actual equipment or devices that are being monitored and/o ...
... MetraBus cable then connects the driver board to one or more I/O boards. The cable can be up to 100 feet long, allowing the host computer and driver board to reside in a controlled environment. The I/O boards can be located remotely near the actual equipment or devices that are being monitored and/o ...
A Simple Approach tyo YIG Oscil
... to the standard layout. So there’s no need to be scared of YIG oscillators! Using them is really quite simple and not critical. If you have a YIG that has the connections laid out in the circuit as described, everything is really clear, even if the pins are not labelled. As a precaution, you can che ...
... to the standard layout. So there’s no need to be scared of YIG oscillators! Using them is really quite simple and not critical. If you have a YIG that has the connections laid out in the circuit as described, everything is really clear, even if the pins are not labelled. As a precaution, you can che ...
equipotential planes, a figment
... Physics. Having the same electric potential at every point.1 equipotential as used in the power industry: (conductor stringing equipment) (power line maintenance) An identical state of electrical potential for two or more items. (PE/T&D) 1048-1990, 516-1995, 524-1992, 524a-1993 equipotential plane a ...
... Physics. Having the same electric potential at every point.1 equipotential as used in the power industry: (conductor stringing equipment) (power line maintenance) An identical state of electrical potential for two or more items. (PE/T&D) 1048-1990, 516-1995, 524-1992, 524a-1993 equipotential plane a ...
experimental characterization regarding two types of
... IR or UV radiation (or none at all) [6]. Therefore, the rest of the power not converted into light is wasted as heat. The efficiency and the lumen output of the devices are strongly dependents on its junction temperature. If no thermal dissipation is provided, the LED can overheat, causing degradati ...
... IR or UV radiation (or none at all) [6]. Therefore, the rest of the power not converted into light is wasted as heat. The efficiency and the lumen output of the devices are strongly dependents on its junction temperature. If no thermal dissipation is provided, the LED can overheat, causing degradati ...
PDR 9000 Operation and Maintenance Manual
... The MKS PDR 9000 Vacuum Gauge Controller displays pressure from 3x10-10 to 1000 Torr, as measured from the MKS 907 Convection Enhanced Pirani and the MKS 903 Inverted Magnetron Cold Cathode Gauge. The PDR 9000 allows operation with either a MKS 907, a MKS 903 or both gauges may be used to provide co ...
... The MKS PDR 9000 Vacuum Gauge Controller displays pressure from 3x10-10 to 1000 Torr, as measured from the MKS 907 Convection Enhanced Pirani and the MKS 903 Inverted Magnetron Cold Cathode Gauge. The PDR 9000 allows operation with either a MKS 907, a MKS 903 or both gauges may be used to provide co ...
doc 90018-031 - Metrix-Vibration Monitoring Solutions
... 4.4 Number of Points per Machine Anywhere from one to four switches are used per machine (depending on how critical the machine is to the process or how expensive it is), one on each end of the motor and one on each end of the compressor, fan, pump or whatever is being driven. If there is a gear bo ...
... 4.4 Number of Points per Machine Anywhere from one to four switches are used per machine (depending on how critical the machine is to the process or how expensive it is), one on each end of the motor and one on each end of the compressor, fan, pump or whatever is being driven. If there is a gear bo ...
Model 701912/701913/701914 PBA1000/2500/1500 Active Probe User’s
... 1. Set up the probe and DL9000 series digital oscilloscope. 2. Before measurement, insert the probe interface completely into the input of the oscilloscope and confirm that the BNC connector and interface pin are securely fastened. When inserting the interface, you will hear a click as the latch c ...
... 1. Set up the probe and DL9000 series digital oscilloscope. 2. Before measurement, insert the probe interface completely into the input of the oscilloscope and confirm that the BNC connector and interface pin are securely fastened. When inserting the interface, you will hear a click as the latch c ...
Form Factors, Power Supplies, and Working Inside a Computer
... systems that sit under a monitor. BTX was designed to take full advantage of serial ATA, USB 2.0, and PCI Express technologies. The BTX form factor design focuses on reducing heat with better airflow and improved fans and coolers. It also gives better structural support for the motherboard than does ...
... systems that sit under a monitor. BTX was designed to take full advantage of serial ATA, USB 2.0, and PCI Express technologies. The BTX form factor design focuses on reducing heat with better airflow and improved fans and coolers. It also gives better structural support for the motherboard than does ...
High-speed and drop-on-demand printing with a pulsed
... level to either obtain a desired droplet diameter or a printing speed (droplets/sec), but not both. The second disadvantage associated with printing by setting a constant voltage different between the tip and substrate accrues from the fact that minute changes in the stand-off height (for example, b ...
... level to either obtain a desired droplet diameter or a printing speed (droplets/sec), but not both. The second disadvantage associated with printing by setting a constant voltage different between the tip and substrate accrues from the fact that minute changes in the stand-off height (for example, b ...
Definition and Classification of Power System Stability IEEE/CIGRE
... forces that exist in the system are equal instantaneously (as in the case of equilibrium points) or over a cycle (as in the case of slow cyclical variations due to continuous small fluctuations in loads or aperiodic attractors). Power systems are subjected to a wide range of disturbances, small and ...
... forces that exist in the system are equal instantaneously (as in the case of equilibrium points) or over a cycle (as in the case of slow cyclical variations due to continuous small fluctuations in loads or aperiodic attractors). Power systems are subjected to a wide range of disturbances, small and ...
MMPF0200Z, 12 Channel Configurable Power Management
... peripherals, in a wide range of applications. With on-chip One Time Programmable (OTP) memory, the PF0200Z is available in preprogrammed standard versions, or non-programmed to support custom programming. The PF0200Z is especially suited to the i.MX 6SoloLite, i.MX 6Solo and i.MX 6DualLite versions ...
... peripherals, in a wide range of applications. With on-chip One Time Programmable (OTP) memory, the PF0200Z is available in preprogrammed standard versions, or non-programmed to support custom programming. The PF0200Z is especially suited to the i.MX 6SoloLite, i.MX 6Solo and i.MX 6DualLite versions ...
PAM8404 Description Pin Assignments
... Thermal protection on the PAM8404 prevents the device from damage when the internal die temperature exceeds +150°C. There is a +15°C tolerance on this trip point from device to device. Once the die temperature exceeds the set point, the device will enter the shutdown state and the outputs are disabl ...
... Thermal protection on the PAM8404 prevents the device from damage when the internal die temperature exceeds +150°C. There is a +15°C tolerance on this trip point from device to device. Once the die temperature exceeds the set point, the device will enter the shutdown state and the outputs are disabl ...
Axis controller CPX-CMAX-C1-1 Terminal CPX
... Accidental movements of the connected actuators can cause collisions, with serious injuries. Dangerous movements due to incorrect control of connected actuators, for example caused by: – untidy or faulty wiring/cabling – errors in operating the components – errors in the measured value and signal en ...
... Accidental movements of the connected actuators can cause collisions, with serious injuries. Dangerous movements due to incorrect control of connected actuators, for example caused by: – untidy or faulty wiring/cabling – errors in operating the components – errors in the measured value and signal en ...
Summary
... specific bypass capacitor requirements. Since these devices are only designed to implement specific tasks in their hard silicon, their power supply demands are fixed and only fluctuate within a certain range. FPGAs do not share this property. Since FPGAs can implement a practically infinite number o ...
... specific bypass capacitor requirements. Since these devices are only designed to implement specific tasks in their hard silicon, their power supply demands are fixed and only fluctuate within a certain range. FPGAs do not share this property. Since FPGAs can implement a practically infinite number o ...
ADC08D500 High Performance, Low Power, Dual 8
... two LVDS buses and reduces the output data rate on each bus to half the sampling rate. The two converters can be interleaved and used as a single 1 GSPS ADC. The converter typically consumes less than 3.5 mW in the Power Down Mode and is available in a 128lead, thermally enhanced exposed pad HLQFP a ...
... two LVDS buses and reduces the output data rate on each bus to half the sampling rate. The two converters can be interleaved and used as a single 1 GSPS ADC. The converter typically consumes less than 3.5 mW in the Power Down Mode and is available in a 128lead, thermally enhanced exposed pad HLQFP a ...
Consequences of the voltage stresses imposed on step
... point of the system [4]. Ferroresonance can only occur in a three-phase system with an isolated neutral in which the following conditions prevail: ...
... point of the system [4]. Ferroresonance can only occur in a three-phase system with an isolated neutral in which the following conditions prevail: ...
Three-Phase Transformer Banks - Lab-Volt
... The need for innovative technologies to make the grid smarter has recently emerged as a major trend, as the increase in electrical power demand observed worldwide makes it harder for the actual grid in many countries to keep up with demand. Furthermore, electric vehicles (from bicycles to cars) are ...
... The need for innovative technologies to make the grid smarter has recently emerged as a major trend, as the increase in electrical power demand observed worldwide makes it harder for the actual grid in many countries to keep up with demand. Furthermore, electric vehicles (from bicycles to cars) are ...
ZXMS6006SG Product Summary Features and Benefits
... 7. The drain current is restricted only when the device is in saturation (see graph ‘typical output characteristic’). This allows the device to be used in the fully on state without interference from the current limit. The device is fully protected at all drain currents, as the low power dissipation ...
... 7. The drain current is restricted only when the device is in saturation (see graph ‘typical output characteristic’). This allows the device to be used in the fully on state without interference from the current limit. The device is fully protected at all drain currents, as the low power dissipation ...
MAX3984 1Gbps to 10Gbps Preemphasis Driver with Receive Equalizer General Description
... Note 6: Using 0000011111 or equivalent pattern at 2.5Gbps. PE0 = PE1 = logic-low for minimum preemphasis. Measured within 2in of the output pins with Rogers 4350 dielectric, or equivalent, and ≥ 10-mil line width. For transition time, the 0% reference is the steady state level after four zeros, just ...
... Note 6: Using 0000011111 or equivalent pattern at 2.5Gbps. PE0 = PE1 = logic-low for minimum preemphasis. Measured within 2in of the output pins with Rogers 4350 dielectric, or equivalent, and ≥ 10-mil line width. For transition time, the 0% reference is the steady state level after four zeros, just ...
Interfaces - Heidenhain
... interface provide voltage signals that can be highly interpolated. The sinusoidal incremental signals A and B are phase-shifted by 90° elec. and have amplitudes of typically 1 VPP. The illustrated sequence of output signals—with B lagging A—applies for the direction of motion shown in the dimension ...
... interface provide voltage signals that can be highly interpolated. The sinusoidal incremental signals A and B are phase-shifted by 90° elec. and have amplitudes of typically 1 VPP. The illustrated sequence of output signals—with B lagging A—applies for the direction of motion shown in the dimension ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.