... 3.4.7 Disabling battery disconnected indication When the power supply is to be used without standby batteries, the battery disconnected warning indication and operation of the common fault relay may be disabled by setting position 1 on the DIP switch to the ON position as show in the diagram below. ...
... 3.4.7 Disabling battery disconnected indication When the power supply is to be used without standby batteries, the battery disconnected warning indication and operation of the common fault relay may be disabled by setting position 1 on the DIP switch to the ON position as show in the diagram below. ...
Induced AC creates problems for pipelines in utility corridors
... be 0.1mA, resulting in a blocking voltage of two volts. In comparison to a polarization cell, the leakage current of a polarization cell is about 50 A at 2 V. To reduce the leakage current to 0.1mA across a polarization cell would require a maximum voltage of only 0.15 V across the cell. Corrosion. ...
... be 0.1mA, resulting in a blocking voltage of two volts. In comparison to a polarization cell, the leakage current of a polarization cell is about 50 A at 2 V. To reduce the leakage current to 0.1mA across a polarization cell would require a maximum voltage of only 0.15 V across the cell. Corrosion. ...
FR011L5J (11mΩ, -30V) Low-Side Reverse Bias / Reverse Polarity
... 1. The V+24 rating is NOT a survival guarantee. It is a statistically calculated survivability reference point taken on qualification devices, where the predicted failure rate is less than 0.01% at the specified voltage for 24 hours. It is intended to indicate the device’s ability to withstand trans ...
... 1. The V+24 rating is NOT a survival guarantee. It is a statistically calculated survivability reference point taken on qualification devices, where the predicted failure rate is less than 0.01% at the specified voltage for 24 hours. It is intended to indicate the device’s ability to withstand trans ...
LT1512 – SEPIC Constant-Current/Constant
... used if the voltage divider is set for less than 3.5V (fully charged battery). Gate drive is equal to battery voltage plus input voltage. The disadvantage of this connection is that Q1 will still be “on” if the VIN voltage is active and the charger is shut down via the S/S pin. The L1 B connection a ...
... used if the voltage divider is set for less than 3.5V (fully charged battery). Gate drive is equal to battery voltage plus input voltage. The disadvantage of this connection is that Q1 will still be “on” if the VIN voltage is active and the charger is shut down via the S/S pin. The L1 B connection a ...
Datasheet - GaN Systems
... The recommended gate drive voltage for optimal RDS(on) performance and long life is +5 to 6 V. The absolute maximum gate-to-source voltage rating is +7.0 V maximum DC. The gate drive can survive transients up to +10 V and – 20 V for pulses up to 1 µs and duty cycle, D, < 0.1. These specifications al ...
... The recommended gate drive voltage for optimal RDS(on) performance and long life is +5 to 6 V. The absolute maximum gate-to-source voltage rating is +7.0 V maximum DC. The gate drive can survive transients up to +10 V and – 20 V for pulses up to 1 µs and duty cycle, D, < 0.1. These specifications al ...
Power over Ethernet (POE) – распиновка
... Power over Ethernet is a technology that allows IP telephones, wireless LAN Access Points, Security network cameras and other IP-based terminals to receive power, in parallel to data, over the existing CAT-5 Ethernet infrastructure without the need to make any modifications in it. Described by IEEE ...
... Power over Ethernet is a technology that allows IP telephones, wireless LAN Access Points, Security network cameras and other IP-based terminals to receive power, in parallel to data, over the existing CAT-5 Ethernet infrastructure without the need to make any modifications in it. Described by IEEE ...
Using the TPS40170EVM-578 Evaluation Module
... TPS40170EVM-578 is designed with a Synchronization mode jumper (J3) using a 3-pin, 0.1-inch spacing header and shunt. Installing a shunt in J3 in the Master position connects the M/S (master/slave) pin to VIN and programs the Master synchronization mode. The TPS40170 controller outputs a 50% duty cy ...
... TPS40170EVM-578 is designed with a Synchronization mode jumper (J3) using a 3-pin, 0.1-inch spacing header and shunt. Installing a shunt in J3 in the Master position connects the M/S (master/slave) pin to VIN and programs the Master synchronization mode. The TPS40170 controller outputs a 50% duty cy ...
BUF11705 22-V Supply, 10+1 Channel Gamma Correction Buffer FEATURES
... and BUF11704 and operates at higher supply voltages up to 22 V (24 V absolute max). The higher supply voltage enables faster response times and brighter images in large-screen LCD panels. This is especially important in LCD TV applications. The BUF11705 offers 10 gamma channels. For additional space ...
... and BUF11704 and operates at higher supply voltages up to 22 V (24 V absolute max). The higher supply voltage enables faster response times and brighter images in large-screen LCD panels. This is especially important in LCD TV applications. The BUF11705 offers 10 gamma channels. For additional space ...
JESD204B Survival Guide
... data. CML outputs are becoming more popular as the digital output interfaces in converters transition to serialized data transmission. However, CMOS and LVDS digital outputs are still being utilized today in current designs. There are applications where each type of digital output is best suited and ...
... data. CML outputs are becoming more popular as the digital output interfaces in converters transition to serialized data transmission. However, CMOS and LVDS digital outputs are still being utilized today in current designs. There are applications where each type of digital output is best suited and ...
Source Impedance - Controlled Power Company
... the impedance of source power supplies, we need an easy way of converting the traditional % impedance (%Z) to milli-ohms (mΩ). The impedance and regulation of a distribution transformer are closely related and both describe the voltage drop across a transformer under a loaded condition, with the reg ...
... the impedance of source power supplies, we need an easy way of converting the traditional % impedance (%Z) to milli-ohms (mΩ). The impedance and regulation of a distribution transformer are closely related and both describe the voltage drop across a transformer under a loaded condition, with the reg ...
EX Module Flyer - Pro
... temperature input, which monitors the temperature sensors in the Mixing Machine via the display, can be done. By using the LT-3201's control function, motor control can be performed based on temperature information. Saving temperature data and control information onto a USB device and recording of m ...
... temperature input, which monitors the temperature sensors in the Mixing Machine via the display, can be done. By using the LT-3201's control function, motor control can be performed based on temperature information. Saving temperature data and control information onto a USB device and recording of m ...
BDTIC www.BDTIC.com/infineon Industrial Power Control
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
Homework Set 3
... (2) Calculate the voltage regulation of this transformer for a full-load current at power factor of 0.8 lagging; (3) Assume that the primary voltage of this transformer is a constant 15 kV, and plot the secondary voltage as a function of load current for currents from no-load to full-load. Repeat th ...
... (2) Calculate the voltage regulation of this transformer for a full-load current at power factor of 0.8 lagging; (3) Assume that the primary voltage of this transformer is a constant 15 kV, and plot the secondary voltage as a function of load current for currents from no-load to full-load. Repeat th ...
FSB50825AB Datasheet
... to make changes without further notice to any products herein. ON Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ON Semiconductor assume any liability arising out of the application or use of any product or ...
... to make changes without further notice to any products herein. ON Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ON Semiconductor assume any liability arising out of the application or use of any product or ...
Humidity Sensor
... Executive (TMEX) software controls the 1-Wire net. Data transfers are half duplex and bit sequential over a single twisted-pair cable using short and long time slots to encode the binary ones and zeros, while power is transmitted during communication idle times. Because every 1-Wire device has a uni ...
... Executive (TMEX) software controls the 1-Wire net. Data transfers are half duplex and bit sequential over a single twisted-pair cable using short and long time slots to encode the binary ones and zeros, while power is transmitted during communication idle times. Because every 1-Wire device has a uni ...
US6K2
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.