
LTM2885 - 6500VRMS Isolated RS485/RS422
... The LTM®2885 is a complete galvanically isolated full-duplex RS485/RS422 µModule® (micromodule) transceiver. No external components are required. A single supply powers both sides of the interface through an integrated, isolated, low noise, efficient 5V output DC/DC converter. Coupled inductors and ...
... The LTM®2885 is a complete galvanically isolated full-duplex RS485/RS422 µModule® (micromodule) transceiver. No external components are required. A single supply powers both sides of the interface through an integrated, isolated, low noise, efficient 5V output DC/DC converter. Coupled inductors and ...
Design of Enhanced MPPT Techniques for Solar and Wind Energy
... voltage and short circuit current method are simple but not efficient for high energy generation units. To improve the performance of the PV system at any weather condition, the two-model MPPT technique is introduced. From the generally used techniques, any two techniques are combined based on the c ...
... voltage and short circuit current method are simple but not efficient for high energy generation units. To improve the performance of the PV system at any weather condition, the two-model MPPT technique is introduced. From the generally used techniques, any two techniques are combined based on the c ...
FLM‑420‑RHV Relay High Voltage Interface Modules
... interface modules used for the activation of fire protection equipment and whose outputs are not monitored, must be installed directly next to or within the device which shall be activated. ...
... interface modules used for the activation of fire protection equipment and whose outputs are not monitored, must be installed directly next to or within the device which shall be activated. ...
SN74LS47 BCD to 7−Segment Decoder/Driver
... These outputs will withstand 15 V with a maximum reverse current of 250 μA. Indicator segments requiring up to 24 mA of current may be driven directly from the SN74LS47 high performance output transistors. Display patterns for BCD input counts above nine are unique symbols to authenticate input cond ...
... These outputs will withstand 15 V with a maximum reverse current of 250 μA. Indicator segments requiring up to 24 mA of current may be driven directly from the SN74LS47 high performance output transistors. Display patterns for BCD input counts above nine are unique symbols to authenticate input cond ...
ZAPI AC3-AC4 Manual
... Digital control based upon a microcontroller Voltage ..................................................................... 36/48 V; 72/80 V; 96 V; 120 V Maximum current (36/48 V)........................................................ 600 A (RMS) for 3' Maximum current (72/80 V)..................... ...
... Digital control based upon a microcontroller Voltage ..................................................................... 36/48 V; 72/80 V; 96 V; 120 V Maximum current (36/48 V)........................................................ 600 A (RMS) for 3' Maximum current (72/80 V)..................... ...
ADN4666 数据手册DataSheet 下载
... Receiver Channel 1 Inverting Input. When this input is more negative than RIN1+, ROUT1 is high. When this input is more positive than RIN1+, ROUT1 is low. Receiver Channel 1 Noninverting Input. When this input is more positive than RIN1−, ROUT1 is high. When this input is more negative than RIN1−, R ...
... Receiver Channel 1 Inverting Input. When this input is more negative than RIN1+, ROUT1 is high. When this input is more positive than RIN1+, ROUT1 is low. Receiver Channel 1 Noninverting Input. When this input is more positive than RIN1−, ROUT1 is high. When this input is more negative than RIN1−, R ...
AN-4151 Half-Bridge LLC Resonant Converter Design Using ™) FSFR-Series Fairchild Power Switch (FPS
... switched-mode power supply has been limited by the size of passive components. Operation at higher frequencies considerably reduces the size of passive components, such as transformers and filters; however, switching losses have been an obstacle to high-frequency operation. To reduce switching losse ...
... switched-mode power supply has been limited by the size of passive components. Operation at higher frequencies considerably reduces the size of passive components, such as transformers and filters; however, switching losses have been an obstacle to high-frequency operation. To reduce switching losse ...
A Draft Standard Glossary of Power Quality - Working Group
... Commercial power is typically referred to as the normal power that is supplied by the incoming feeders. This in some cases may include some portion of generated power from local generators supplied by natural gas, diesel fuel or coal. Generally, the incoming service power is regarded as commercial p ...
... Commercial power is typically referred to as the normal power that is supplied by the incoming feeders. This in some cases may include some portion of generated power from local generators supplied by natural gas, diesel fuel or coal. Generally, the incoming service power is regarded as commercial p ...
Ω MAX9153/MAX9154 Low-Jitter, 800Mbps, 10-Port LVDS Repeaters with 100
... 90Ω to 132Ω to accommodate various types of interconnect. The termination resistor should match the differential characteristic impedance of the interconnect and be located close to the LVDS receiver input. Use a ±1% surface-mount termination resistor. The output voltage swing is determined by the v ...
... 90Ω to 132Ω to accommodate various types of interconnect. The termination resistor should match the differential characteristic impedance of the interconnect and be located close to the LVDS receiver input. Use a ±1% surface-mount termination resistor. The output voltage swing is determined by the v ...
Technics
... This outlet is exclusively f or the connection of other audio equipment, such as a tape deck. Be sure the power consumption does not exceed the wattage specified near the AC outlet. Never connect other electrical appliances, such as an iron or toaster. lf appliances with a large power consumption ar ...
... This outlet is exclusively f or the connection of other audio equipment, such as a tape deck. Be sure the power consumption does not exceed the wattage specified near the AC outlet. Never connect other electrical appliances, such as an iron or toaster. lf appliances with a large power consumption ar ...
Capacitor Bank Designing for Power Factor Improvement
... are shown in Fig. 4. Ungrounded wye banks do not permit zero sequence currents, third harmonic currents, or large capacitor discharge currents during system ground faults to flow. (Phase-to-phase faults may still occur and will result in large discharge currents). Other advantage is that overvoltage ...
... are shown in Fig. 4. Ungrounded wye banks do not permit zero sequence currents, third harmonic currents, or large capacitor discharge currents during system ground faults to flow. (Phase-to-phase faults may still occur and will result in large discharge currents). Other advantage is that overvoltage ...
BDTIC ICB2FL01G Highly integrated Smart Ballast Controller for Fluorescent Lamps
... liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (www.infineon ...
... liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (www.infineon ...
Transmission Planning Reliability Criteria - AEP PJM
... during normal and emergency conditions. The low limit can be lower if voltage regulating equipment maintains voltage to the customers within prescribed limits at distribution substations involved without causing voltage problems at nearby loads. Voltage fluctuations (flicker) are addressed in the AE ...
... during normal and emergency conditions. The low limit can be lower if voltage regulating equipment maintains voltage to the customers within prescribed limits at distribution substations involved without causing voltage problems at nearby loads. Voltage fluctuations (flicker) are addressed in the AE ...
MAX6978 8-Port, 5.5V Constant-Current LED Driver with LED Fault Detection and Watchdog
... to 5.5V supply. The MAX6978 supply and the LEDs’ supply can power up in any order. The constant-current outputs are programmed together to up to 55mA using a single external resistor. The MAX6978 operates with a 25Mb, industry-standard, 4-wire serial interface. The MAX6978 includes circuitry that au ...
... to 5.5V supply. The MAX6978 supply and the LEDs’ supply can power up in any order. The constant-current outputs are programmed together to up to 55mA using a single external resistor. The MAX6978 operates with a 25Mb, industry-standard, 4-wire serial interface. The MAX6978 includes circuitry that au ...
LMH6551 Differential, High Speed Op Amp
... The LMH6551 is a fully differential amplifier designed to provide low distortion amplification to wide bandwidth differential signals. The LMH6551, though fully integrated for ultimate balance and distortion performance, functionally provides three channels. Two of these channels are the V+ and V− s ...
... The LMH6551 is a fully differential amplifier designed to provide low distortion amplification to wide bandwidth differential signals. The LMH6551, though fully integrated for ultimate balance and distortion performance, functionally provides three channels. Two of these channels are the V+ and V− s ...
US6M2 - Rohm
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
Power-Combined Multipliers at 60 GHz Based on Fundamental
... fabrication and assembly errors which are unavoidable. The devices need to be electrically identical, and the alignment of the manually assembled device needs to be very accurate. Once fabrication and assembly errors occur, the power-combined efficiency will decrease, and it is impossible to repair. O ...
... fabrication and assembly errors which are unavoidable. The devices need to be electrically identical, and the alignment of the manually assembled device needs to be very accurate. Once fabrication and assembly errors occur, the power-combined efficiency will decrease, and it is impossible to repair. O ...
X15
... stability, large power, high efficiency and accurate sound performance.Now we can see many classes of audio power amplifier such as: class A class AB class D class H and others. They were named for one unique technology. In the field of professional amplifier, no matter what technology we use, we al ...
... stability, large power, high efficiency and accurate sound performance.Now we can see many classes of audio power amplifier such as: class A class AB class D class H and others. They were named for one unique technology. In the field of professional amplifier, no matter what technology we use, we al ...
LM348-N 数据资料 dataSheet 下载
... independent, high gain, internally compensated, low power operational amplifiers which have been designed to provide functional characteristics identical to those of the familiar 741 operational amplifier. In addition the total supply current for all four amplifiers is comparable to the supply curre ...
... independent, high gain, internally compensated, low power operational amplifiers which have been designed to provide functional characteristics identical to those of the familiar 741 operational amplifier. In addition the total supply current for all four amplifiers is comparable to the supply curre ...
waverider1_Spec - Crucial Power Products
... The system shall utilize high frequency pulse width modulation and digital signal processing for control and monitoring. The system's automatic overload and short circuit protection of the inverter in normal and emergency operations shall have 150% momentary surge capability and withstand a 115% ove ...
... The system shall utilize high frequency pulse width modulation and digital signal processing for control and monitoring. The system's automatic overload and short circuit protection of the inverter in normal and emergency operations shall have 150% momentary surge capability and withstand a 115% ove ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.