
enclosed meters
... The Eaton enclosed meter line provides a complete energy metering and data acquisition solution in a single enclosure. Designed for Eaton’s IQ 35M, IQ 150, IQ 250/260, and Power Xpert® 2000/4000/6000/8000 and Multi-Point Meters, Eaton’s enclosed meter line offers mounting and installation flexibilit ...
... The Eaton enclosed meter line provides a complete energy metering and data acquisition solution in a single enclosure. Designed for Eaton’s IQ 35M, IQ 150, IQ 250/260, and Power Xpert® 2000/4000/6000/8000 and Multi-Point Meters, Eaton’s enclosed meter line offers mounting and installation flexibilit ...
MAX17480 AMD 2-/3-Output Mobile Serial VID Controller General Description
... consists of two high-current SMPSs for the CPU cores and one 4A internal switch SMPS for the NB core. The two CPU core SMPSs run 180° out-of-phase for true interleaved operation, minimizing input capacitance. The 4A internal switch SMPS runs at twice the switching frequency of the core SMPS, reducin ...
... consists of two high-current SMPSs for the CPU cores and one 4A internal switch SMPS for the NB core. The two CPU core SMPSs run 180° out-of-phase for true interleaved operation, minimizing input capacitance. The 4A internal switch SMPS runs at twice the switching frequency of the core SMPS, reducin ...
Synthesis and Analysis of a Series-Connected Switched-Capacitor DC-DC converter Kei Eguchi , Non-member
... converter by using a family of the charge-averaging type converter. Different from conventional converters, the proposed converter provides only Q/P (P ∈ {2, 3, . . . , N } and Q ∈ {1, 2, . . . , N − 1}) stepped-down voltages. However, the number of power switches for the proposed converter is less ...
... converter by using a family of the charge-averaging type converter. Different from conventional converters, the proposed converter provides only Q/P (P ∈ {2, 3, . . . , N } and Q ∈ {1, 2, . . . , N − 1}) stepped-down voltages. However, the number of power switches for the proposed converter is less ...
Troubleshooting Corvette gauges
... gauge to read low. The amount the gauge reads low is a function of the amount of corrosion (resistance) on the terminals. This can appear at the connector to the sender, at the bulkhead connector, or at the plug on the back of the panel gauge. If the instrument cluster does not have a good ground, t ...
... gauge to read low. The amount the gauge reads low is a function of the amount of corrosion (resistance) on the terminals. This can appear at the connector to the sender, at the bulkhead connector, or at the plug on the back of the panel gauge. If the instrument cluster does not have a good ground, t ...
Power Electronics - Dr. Imtiaz Hussain
... 3. Like the SCR once the triac is fired into conduction, the gate lose all control. The triac can be turned off by reducing the circuit current to the value of holding current. 4. The main disadvantage of triacs of SCRs is that triacs have considerably lower current handling capabilities. Most triac ...
... 3. Like the SCR once the triac is fired into conduction, the gate lose all control. The triac can be turned off by reducing the circuit current to the value of holding current. 4. The main disadvantage of triacs of SCRs is that triacs have considerably lower current handling capabilities. Most triac ...
12 A, 200 V, Ultrafast Dual Diode Features
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
Insulation coordination studies
... overvoltages are determined, both line-to-earth and line-to-line, and used as an input for the insulation coordination procedure. Application of insulation coordination procedure From the worst case overvoltages, resulting from the simulation studies, the required insulation levels for different typ ...
... overvoltages are determined, both line-to-earth and line-to-line, and used as an input for the insulation coordination procedure. Application of insulation coordination procedure From the worst case overvoltages, resulting from the simulation studies, the required insulation levels for different typ ...
Low power factor
... factor of loads at a nominal value. In any case, the power factor of the load should generally be around 0.8 (unless there is a particular reason for it), as this is the most cost effective value. A lower power factor will lead to higher losses, which will reduce the efficiency of the circuit. But i ...
... factor of loads at a nominal value. In any case, the power factor of the load should generally be around 0.8 (unless there is a particular reason for it), as this is the most cost effective value. A lower power factor will lead to higher losses, which will reduce the efficiency of the circuit. But i ...
- Pcpolytechnic
... Analog information is continuous and stepless function of time. Analog instruments are easy to understand, calibrate and maintain. Digital information is in form of discrete pulses or steps. Digital instruments have higher ...
... Analog information is continuous and stepless function of time. Analog instruments are easy to understand, calibrate and maintain. Digital information is in form of discrete pulses or steps. Digital instruments have higher ...
NCL30060 - ON Semiconductor
... The NCL30060 is a switch mode power supply controller intended for low to medium power single stage power factor (PF) corrected LED Drivers. It employs a constant on−time control method to ensure near unity power factor across a wide range of input voltages and output power. It can be used for isola ...
... The NCL30060 is a switch mode power supply controller intended for low to medium power single stage power factor (PF) corrected LED Drivers. It employs a constant on−time control method to ensure near unity power factor across a wide range of input voltages and output power. It can be used for isola ...
MAX1544 Dual-Phase, Quick-PWM Controller for AMD Hammer CPU Core Power Supplies General Description
... The MAX1544 is a dual-phase, Quick-PWM™, stepdown controller for AMD Hammer™ CPU core supplies. Dual-phase operation reduces input ripple current requirements and output voltage ripple while easing component selection and layout difficulties. The QuickPWM control scheme provides instantaneous respon ...
... The MAX1544 is a dual-phase, Quick-PWM™, stepdown controller for AMD Hammer™ CPU core supplies. Dual-phase operation reduces input ripple current requirements and output voltage ripple while easing component selection and layout difficulties. The QuickPWM control scheme provides instantaneous respon ...
LTC3108 - Ultralow Voltage Step-Up Converter
... The active circuits within the LTC3108 are powered from VAUX, which should be bypassed with a 1µF capacitor. Larger capacitor values are recommended when using turns ratios of 1:50 or 1:20 (refer to the Typical Application examples). Once VAUX exceeds 2.5V, the main VOUT is allowed to start charging ...
... The active circuits within the LTC3108 are powered from VAUX, which should be bypassed with a 1µF capacitor. Larger capacitor values are recommended when using turns ratios of 1:50 or 1:20 (refer to the Typical Application examples). Once VAUX exceeds 2.5V, the main VOUT is allowed to start charging ...
High-Performance Adaptive Perturb and Observe MPPT Technique
... two successive array power signals calculated from the measured array voltage and current signals to create an adaptive perturb. Basically, at the start of the hill climbing process, this error is large and decreases as the maximum power operating point is approached at steady state. Therefore, this ...
... two successive array power signals calculated from the measured array voltage and current signals to create an adaptive perturb. Basically, at the start of the hill climbing process, this error is large and decreases as the maximum power operating point is approached at steady state. Therefore, this ...
Lesson 1 - Introduction
... • This channel allows the current to pass from the drain terminal to the source terminal. • With low values of vDS (i.e., vDS << vGS), the channel shape is uniform. ...
... • This channel allows the current to pass from the drain terminal to the source terminal. • With low values of vDS (i.e., vDS << vGS), the channel shape is uniform. ...
MAX3272/MAX3272A +3.3V, 2.5Gbps Low-Power Limiting Amplifiers General Description
... Two control voltages VASSERT, and VDEASSERT, define the LOS assert and deassert levels. To prevent LOS chatter in the region of the programmed threshold, approximately 3.3dB of hysteresis is built into the LOS assert/deassert function. Once asserted, LOS is not deasserted until the input amplitude r ...
... Two control voltages VASSERT, and VDEASSERT, define the LOS assert and deassert levels. To prevent LOS chatter in the region of the programmed threshold, approximately 3.3dB of hysteresis is built into the LOS assert/deassert function. Once asserted, LOS is not deasserted until the input amplitude r ...
CHAPTER 20 WRIGHT STATE UNIVERSITY
... pulse, the microcontroller broadcasts addresses from one to 15, and then polls the input pins for locations one to four in order to detect response. When a response occurs, the microcontroller associates the toy address to the location that responds. To detect a pulling response, a simple limit swit ...
... pulse, the microcontroller broadcasts addresses from one to 15, and then polls the input pins for locations one to four in order to detect response. When a response occurs, the microcontroller associates the toy address to the location that responds. To detect a pulling response, a simple limit swit ...
AD588 数据手册DataSheet 下载
... temperature compensation circuitry provides the device with a temperature coefficient of 1.5 ppm/°C or less. Amplifier A1 performs several functions. A1 primarily acts to amplify the Zener voltage from 6.5 V to the required 10 V output. In addition, A1 provides for external adjustment of the 10 V ou ...
... temperature compensation circuitry provides the device with a temperature coefficient of 1.5 ppm/°C or less. Amplifier A1 performs several functions. A1 primarily acts to amplify the Zener voltage from 6.5 V to the required 10 V output. In addition, A1 provides for external adjustment of the 10 V ou ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.