PM-45X - Texmate, Inc
... Pin 7 is internally connected to the LCD back plane which is the common base of the LCD capacitance structure. Those segments that are driven 180° out-ofphase with the back plane will turn on. Those segments that are driven in-phase with the back plane will turn off. Pin J - Clock Output: A quartz c ...
... Pin 7 is internally connected to the LCD back plane which is the common base of the LCD capacitance structure. Those segments that are driven 180° out-ofphase with the back plane will turn on. Those segments that are driven in-phase with the back plane will turn off. Pin J - Clock Output: A quartz c ...
Transformer Basics Information Guide
... Buck/Boost Normally used when only a small change in voltage is required (20% or less), such as 208V to 240V (Boost) or 240V to 208V (Buck). This type system does not provide isolation, but is more cost effective if isolation is not required. A Buck/Boost transformer is also referred to as an “Auto ...
... Buck/Boost Normally used when only a small change in voltage is required (20% or less), such as 208V to 240V (Boost) or 240V to 208V (Buck). This type system does not provide isolation, but is more cost effective if isolation is not required. A Buck/Boost transformer is also referred to as an “Auto ...
Slides - Indico
... • As a SCRF cavity would quench long before breakdown, we only see breakdown in normal conducting structures. ...
... • As a SCRF cavity would quench long before breakdown, we only see breakdown in normal conducting structures. ...
Número de publicación
... The panel has a drive unit (32) introducing drive movements in each switching pole (25, 28, 30). The poles are connected with bus bar connectors (3-5) by controllable contact systems (9, 10, 11), where the contact systems are controlled such that conductive connection is formed between the switching ...
... The panel has a drive unit (32) introducing drive movements in each switching pole (25, 28, 30). The poles are connected with bus bar connectors (3-5) by controllable contact systems (9, 10, 11), where the contact systems are controlled such that conductive connection is formed between the switching ...
Datasheet
... The TH8056 is a physical layer device for a single wire data link capable of operating with various CSMA/CR protocols such as the Bosch Controller Area Network (CAN) version 2.0. This serial data link network is intended for use in applications where a high data rate is not required and a lower data ...
... The TH8056 is a physical layer device for a single wire data link capable of operating with various CSMA/CR protocols such as the Bosch Controller Area Network (CAN) version 2.0. This serial data link network is intended for use in applications where a high data rate is not required and a lower data ...
Animal Contact Current Mitigation
... (h) "Cycle" means 1 complete positive and 1 complete negative alternation of current or voltage. (i) "Direct current" (DC) means a current that flows in only 1 direction, in and through a conductive material. (j) "Harmonics" means a repeating sine wave that fits within the main sine wave. The main s ...
... (h) "Cycle" means 1 complete positive and 1 complete negative alternation of current or voltage. (i) "Direct current" (DC) means a current that flows in only 1 direction, in and through a conductive material. (j) "Harmonics" means a repeating sine wave that fits within the main sine wave. The main s ...
micromaster 440
... CAUTION ¾ Children and the general public must be prevented from accessing or approaching the equipment! ¾ This equipment may only be used for the purpose specified by the manufacturer. Unauthorized modifications and the use of spare parts and accessories that are not sold or recommended by the manu ...
... CAUTION ¾ Children and the general public must be prevented from accessing or approaching the equipment! ¾ This equipment may only be used for the purpose specified by the manufacturer. Unauthorized modifications and the use of spare parts and accessories that are not sold or recommended by the manu ...
BFQ790 for 433 MHz Smart Metering Applications
... attach with good thermal contact is 100% tested, so that there is minimum variation of thermal properties. The device is based on Infineon's reliable and cost-effective NPN SiGe technology running in high volume. The collector design allows safe operation with 5 V supply voltage. The BFQ790 is very ...
... attach with good thermal contact is 100% tested, so that there is minimum variation of thermal properties. The device is based on Infineon's reliable and cost-effective NPN SiGe technology running in high volume. The collector design allows safe operation with 5 V supply voltage. The BFQ790 is very ...
NA555, NE555, SA555, SE555 Precision Timers
... threshold input is above the threshold level, the flipflop is reset and the output is low. The reset (RESET) input can override all other inputs and can be used to initiate a new timing cycle. When RESET goes low, the flip-flop is reset, and the output goes low. When the output is low, a low-impedan ...
... threshold input is above the threshold level, the flipflop is reset and the output is low. The reset (RESET) input can override all other inputs and can be used to initiate a new timing cycle. When RESET goes low, the flip-flop is reset, and the output goes low. When the output is low, a low-impedan ...
XHR 1000 Watt Series Programmable DC Power Supply
... installation and servicing. Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ...
... installation and servicing. Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ...
LTC6915 - Linear Technology
... Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: These parameters are tested at ±5V supply; at 3V and 5V supplies th ...
... Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: These parameters are tested at ±5V supply; at 3V and 5V supplies th ...
Sectionalization - IEEE Rural Electric Power Conference
... Must be compatible with the existing loop & radial distribution system. Minimize impact on existing overcurrent protection & coordination. Minimize impact on settings/operation of existing equipment. D-SCADA capable for switching. Communications not required for loop operation. Compare favorably wit ...
... Must be compatible with the existing loop & radial distribution system. Minimize impact on existing overcurrent protection & coordination. Minimize impact on settings/operation of existing equipment. D-SCADA capable for switching. Communications not required for loop operation. Compare favorably wit ...
LTC4080
... below 2.9V for one quarter of the full charge time, the battery is considered defective, and the ⎯C⎯H⎯R⎯G pin pulses at a frequency of 2Hz with 75% duty cycle. FB (Pin 7): Feedback Pin for the Buck Regulator. A resistor divider from the regulator’s output to the FB pin programs the output voltage. S ...
... below 2.9V for one quarter of the full charge time, the battery is considered defective, and the ⎯C⎯H⎯R⎯G pin pulses at a frequency of 2Hz with 75% duty cycle. FB (Pin 7): Feedback Pin for the Buck Regulator. A resistor divider from the regulator’s output to the FB pin programs the output voltage. S ...
Requirements concerning ELECTRICAL AND ELECTRONIC
... protection may be required to be disconnected for this test. - For high voltage equipment, reference is made to UR E11. - separate circuits are to be tested against each other and all circuits connected with each other tested against earth; - printed circuits with electronic components may be remove ...
... protection may be required to be disconnected for this test. - For high voltage equipment, reference is made to UR E11. - separate circuits are to be tested against each other and all circuits connected with each other tested against earth; - printed circuits with electronic components may be remove ...
Digital Multimeter Instruction Manual MS6574
... mounted on the engine, the procedure is similar to checking the starter motor off the engine. The battery cable and key switch harness installed in the equipment may be substituted for the test harness shown. When making this current draw test, it is important to monitor the engine RPM, amperage dra ...
... mounted on the engine, the procedure is similar to checking the starter motor off the engine. The battery cable and key switch harness installed in the equipment may be substituted for the test harness shown. When making this current draw test, it is important to monitor the engine RPM, amperage dra ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.