
Comet 40-150kVA
... This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
... This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
Selection Guide to Clamp-On Current Probes
... First, since the Hall voltage is not dependent on a reversing magnetic field, but only on its strength, the device can be used for DC measurement. Second, when the magnetic field strength varies due to varying current flow in the conductor, response to change is instantaneous. Thus, complex AC wave ...
... First, since the Hall voltage is not dependent on a reversing magnetic field, but only on its strength, the device can be used for DC measurement. Second, when the magnetic field strength varies due to varying current flow in the conductor, response to change is instantaneous. Thus, complex AC wave ...
PW1000 1-3 kVA Tech Spec.fm
... • Highly efficient PWM sine-wave technology yields excellent UPS efficiency. The high crest factor of the inverter handles peak inrush current loads and so avoids a need to upgrade to a UPS with a higher power rating. • Fully digitized control logic for better functionality and high quality output p ...
... • Highly efficient PWM sine-wave technology yields excellent UPS efficiency. The high crest factor of the inverter handles peak inrush current loads and so avoids a need to upgrade to a UPS with a higher power rating. • Fully digitized control logic for better functionality and high quality output p ...
FDS6676AS 30V N SyncFET
... The FDS6676AS is designed to replace a single SO-8 MOSFET and Schottky diode in synchronous DC:DC power supplies. This 30V MOSFET is designed to maximize power conversion efficiency, providing a low RDS(ON) and low gate charge. The FDS6676AS includes an integrated Schottky diode using Fairchild’s mo ...
... The FDS6676AS is designed to replace a single SO-8 MOSFET and Schottky diode in synchronous DC:DC power supplies. This 30V MOSFET is designed to maximize power conversion efficiency, providing a low RDS(ON) and low gate charge. The FDS6676AS includes an integrated Schottky diode using Fairchild’s mo ...
P84453
... than the signaling appliance) through the backbox. Such additional wires could result in insufficient wiring space for the signaling appliance. ...
... than the signaling appliance) through the backbox. Such additional wires could result in insufficient wiring space for the signaling appliance. ...
user`s manual
... Typical examples for analog controls connected to the pin headers ST1…ST4 are modulation wheels, foot controllers, joy sticks, rotary potentiometers, faders, drawbars, rotary switches (with resistor chains connected between GND and +5V to generate several analog voltages), ribbon controllers, pressu ...
... Typical examples for analog controls connected to the pin headers ST1…ST4 are modulation wheels, foot controllers, joy sticks, rotary potentiometers, faders, drawbars, rotary switches (with resistor chains connected between GND and +5V to generate several analog voltages), ribbon controllers, pressu ...
PW1000 1-3 kVA Tech Spec.fm - Uninterruptible Power Supplies Ltd
... • Highly efficient PWM sine-wave technology yields excellent UPS efficiency. The high crest factor of the inverter handles peak inrush current loads and so avoids a need to upgrade to a UPS with a higher power rating. • Fully digitized control logic for better functionality and high quality output p ...
... • Highly efficient PWM sine-wave technology yields excellent UPS efficiency. The high crest factor of the inverter handles peak inrush current loads and so avoids a need to upgrade to a UPS with a higher power rating. • Fully digitized control logic for better functionality and high quality output p ...
ASCO Model 440 Guide Specifications (word version)
... Component Testing and Monitoring: The proposed product shall be single pulsed surge current tested in all modes at the rated surge currents by an industry recognized independent test laboratory. The test shall include a surge impulse (6kV [1.2x50µs], 500 amp [8x20 s] waveform) to benchmark the unit ...
... Component Testing and Monitoring: The proposed product shall be single pulsed surge current tested in all modes at the rated surge currents by an industry recognized independent test laboratory. The test shall include a surge impulse (6kV [1.2x50µs], 500 amp [8x20 s] waveform) to benchmark the unit ...
docx
... (2674):The vlow and vhigh entries accept analog voltage values which must correspond to the digital off and on states, where the vhigh value must be greater than the vlow value. When polarity is Non-Inverting, vlow corresponds to the digital off state '0', vhigh corresponds to the digital on state ' ...
... (2674):The vlow and vhigh entries accept analog voltage values which must correspond to the digital off and on states, where the vhigh value must be greater than the vlow value. When polarity is Non-Inverting, vlow corresponds to the digital off state '0', vhigh corresponds to the digital on state ' ...
Digitally Controlled Pulse Width Modulator for On
... During the first phase, capacitor C1 is charged through transistor P1 . In the second phase, transistors (i.e., switches) N2 and N3 are turned on to allow charge sharing between C1 and C2 . During the last phase, C1 is discharged through N1 . The charge time of C1 depends upon the duty cycle of the ...
... During the first phase, capacitor C1 is charged through transistor P1 . In the second phase, transistors (i.e., switches) N2 and N3 are turned on to allow charge sharing between C1 and C2 . During the last phase, C1 is discharged through N1 . The charge time of C1 depends upon the duty cycle of the ...
General Specifications UP35A Program Controller
... Setting only the minimum necessary parameters for operation is possible. (For single-loop control only) • Equipped with a multitude of functions Universal I/O and eight control modes (cascade control, etc) are included as standard. PID control, heating/cooling control, feed forward control, etc. ...
... Setting only the minimum necessary parameters for operation is possible. (For single-loop control only) • Equipped with a multitude of functions Universal I/O and eight control modes (cascade control, etc) are included as standard. PID control, heating/cooling control, feed forward control, etc. ...
Evaluation and Practice Test - E Light Safety, Training and
... 10. What is the demand on the main service entrance for a multi-family dwelling unit for the electric dryers? The service will be 240V, single phase. There are 14 apartments in the dwelling and each apartment is equipped with a 4.2 kW dryer. A. 24,000 w B. 30,800 W C. 45,000 W D. 70,000 W 11. The ou ...
... 10. What is the demand on the main service entrance for a multi-family dwelling unit for the electric dryers? The service will be 240V, single phase. There are 14 apartments in the dwelling and each apartment is equipped with a 4.2 kW dryer. A. 24,000 w B. 30,800 W C. 45,000 W D. 70,000 W 11. The ou ...
ADG3243 数据手册DataSheet 下载
... Quiescent Power Supply Current. This current represents the leakage current between the VCC and ground pins. It is measured when all control inputs are at a logic high or low level and the switches are OFF. Extra power supply current component for the EN control input when the input is not driven at ...
... Quiescent Power Supply Current. This current represents the leakage current between the VCC and ground pins. It is measured when all control inputs are at a logic high or low level and the switches are OFF. Extra power supply current component for the EN control input when the input is not driven at ...
Application of MATLAB/SIMULINK in Solar PV Systems
... value when compared to the module efficiency, this being due to conductance losses, e.g., in cables. In the case of inverter, it converts the DC output from the Solar PV module to the AC grid voltage with a certain degree of efficiency. It depends upon conversion efficiency and the precision and qui ...
... value when compared to the module efficiency, this being due to conductance losses, e.g., in cables. In the case of inverter, it converts the DC output from the Solar PV module to the AC grid voltage with a certain degree of efficiency. It depends upon conversion efficiency and the precision and qui ...
S8VM (15/30/50/100/150/300/600/1,500
... 3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual ou ...
... 3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual ou ...
Application of Artificial Neural Network (ANN) technique for the
... The proposed methodology for monitoring and assessment voltage stability is based on self-organized and multilayered feed forwarded artificial neural networks (ANNs). It consists of four stage: 1) configuration and design procedure. 2) Stability analysis. 3) Reduction of system model using a self or ...
... The proposed methodology for monitoring and assessment voltage stability is based on self-organized and multilayered feed forwarded artificial neural networks (ANNs). It consists of four stage: 1) configuration and design procedure. 2) Stability analysis. 3) Reduction of system model using a self or ...
AP1695 Description Features
... The AP1695 internally integrates a 500V high voltage MOSFET which can realize a lower BOM cost. The AP1695 provides accurate constant current (CC) regulation while removing the opto-coupler and secondary control circuitry. It also eliminates the need of loop compensation circuitry while maintaining ...
... The AP1695 internally integrates a 500V high voltage MOSFET which can realize a lower BOM cost. The AP1695 provides accurate constant current (CC) regulation while removing the opto-coupler and secondary control circuitry. It also eliminates the need of loop compensation circuitry while maintaining ...
Keyword: [GND Clamp Reference]
... Clamp] structures are “Vcc relative”, meaning that the voltage values are referenced to the Vcc pin. (Note that, under these keywords, all references to “Vcc” refer to the voltage rail defined by the [Voltage Range], [Pullup Reference], or [POWER Clamp Reference] keywords, as appropriate.) The volta ...
... Clamp] structures are “Vcc relative”, meaning that the voltage values are referenced to the Vcc pin. (Note that, under these keywords, all references to “Vcc” refer to the voltage rail defined by the [Voltage Range], [Pullup Reference], or [POWER Clamp Reference] keywords, as appropriate.) The volta ...
PAM2306 Description Pin Assignments
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
part 2 products - GE Grid Solutions
... servicing of UPS. Any factory trained service provider shall be capable of performing maintenance and repair of the UPS. Calibration and diagnostics of the UPS shall be performed either remotely or thru the front display and shall be facilitated thru programmable parameters. Potentiometers shall not ...
... servicing of UPS. Any factory trained service provider shall be capable of performing maintenance and repair of the UPS. Calibration and diagnostics of the UPS shall be performed either remotely or thru the front display and shall be facilitated thru programmable parameters. Potentiometers shall not ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.