• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Design of SVPWM Inverter for Induction Motor Drive Using
Design of SVPWM Inverter for Induction Motor Drive Using

... On the other hand, in electric traction, the use of power is either DC or AC. Three phase DC/AC inverter is the only possible interface due to their flexible voltage and frequency variation. As mentioned above, a three phase DC/AC inverter used in traction is supplied by power either in AC or DC. In ...
File - Science with Ms. Tantri
File - Science with Ms. Tantri

... Parts of a Motor Cell – Provides current Field magnet – Provides external magnetic field Coil - Part of the motor that rotates (armature) ...
cc196880ad09e14
cc196880ad09e14

... converter part on it`s terminals in order not to have ripples and it feed the inverter part. ...
ELECTRICAL STUFF FOR MECHANICAL ENGINEERS
ELECTRICAL STUFF FOR MECHANICAL ENGINEERS

... • FLA (full load amperes)is the current the devise draws when operating under full rated load. This is a nameplate rating of a device such as a motor. • MCA (minimum circuit amperes) is the minimum allowable current rating of the circuit serving the equipment. This equipment usually has more than on ...
The Use of Variable Frequency Drives Engineering Bulletin
The Use of Variable Frequency Drives Engineering Bulletin

24_Banach_newp - Instytut Maszyn, Napędów i Pomiarów
24_Banach_newp - Instytut Maszyn, Napędów i Pomiarów

... For every load exists an optimal value of voltage which reduces the losses. This optimal voltage can be determined by using an analytical method, which was worked out by author. The application of this method requires knowledge of core and mechanical losses, magnetization characteristic, voltage dro ...
Magnetic Switch・Magnetic Contactor Manual DANGER CAUTION
Magnetic Switch・Magnetic Contactor Manual DANGER CAUTION

Micrmouse
Micrmouse

... H-Bridge • DC motors only have two leads. The direction it spins is determined by which terminal has power applied and which is connected to ground. • An H-bridge consists of four switches (in our case BJTs) and depending on which two are closed, allow the motor to operate in either direction • We ...
Ttitle, Title, Title, Ttitle, Title, Title, Ttitle, Title, Title
Ttitle, Title, Title, Ttitle, Title, Title, Ttitle, Title, Title

... rate of the individual components and achieves an MTBF (mean time between failures as per SN 29500) rate of over 5 million hours at full load. This means that safe IGBT control is ensured even for the long working lives of industrial drives. A new generation of mixed-signal ASICs achieves a high lev ...
DI-124 Design Idea LinkSwitch-TN
DI-124 Design Idea LinkSwitch-TN

... • StackFETTM flyback topology delivers full load over extremely wide input voltage range • E-ShieldTM transformer construction for reduced common-mode EMI (>10 dBmV margin) • 66 kHz switching frequency with jitter reduces conducted EMI • Simple ON/OFF controller – no feedback compensation requir ...
Power Converters for Industrial Power Supply System Power Electronics & Automation
Power Converters for Industrial Power Supply System Power Electronics & Automation

A Simulation Study of the PWM Strategy for Inverters
A Simulation Study of the PWM Strategy for Inverters

... Study Issues: PWM Principle & Power Factor Control 1. Illustration of PWM Principle: Set the modulation index with 0.75 and modulation frequency of 60 Hz, apply SPWM to the inverter Complete the simulation of (1) by using SPWM and show some selected variables shown in the following figure to illust ...
Texas Instruments Integrated Power Conference
Texas Instruments Integrated Power Conference

... Off trajectories converge to 60V, 15A point, because this is the value of the input voltage and the load ...
An Improved Hybrid DSTATCOM Topology to Compensate Reactive
An Improved Hybrid DSTATCOM Topology to Compensate Reactive

... topology to address some practical issues such as power rating, filter size, compensation performance, and power loss. An LCL filter has been used at the front end of a voltage source inverter (VSI), which provides better switching harmonics elimination while using much smaller value of an inductor ...
DI 507B - Dionics-USA
DI 507B - Dionics-USA

... The DIONICS DI-507B and DI-512B series circuits are designed for interfacing between MOS or TTL circuitry and gas discharge display panels. Each section of these devices is made up of a switched constant current level shifter-capable of high voltage operation and a PNP-NPN driver transistor pair. Th ...
overloads - Controlled Power Company
overloads - Controlled Power Company

V = 40 + j35 volts I = 6 + j3 amps The above is the pd across a circuit
V = 40 + j35 volts I = 6 + j3 amps The above is the pd across a circuit

... ...
Purpose Buck-Boost Chopper Type AC Voltage Controller
Purpose Buck-Boost Chopper Type AC Voltage Controller

... fields such as power system, motor speed control and so on. There are also other researches which use thyristor phase controlled circuit to do voltage regulation.But they have some disadvantages and those arise problems. These problems can be solved by using high switching frequency AC chopper i.e. ...
Using Low Voltage MicroGrids in Emergency Conditions
Using Low Voltage MicroGrids in Emergency Conditions

V p
V p

Student
Student

05 - H-Bridge Motor Control
05 - H-Bridge Motor Control

Document
Document

... in the capacitor voltages is eliminated by adding a feedback term (the difference in the capacitor voltages multiplied by a suitable gain) to the current control. The proposed control strategy offers a reduced switching frequency, losses and cost. The steady-state and dynamic performance of the prop ...
No Slide Title
No Slide Title

... several times ( up to about 6 times) its rated current. As the load accelerates, the available torque usually drops a little and then rises to a peak while the current remains very high until the motor approaches full speed. By contrast, when a VFD starts a motor, it initially applies a low frequenc ...
Simulation and Speed Control of 3-Phase Induction Motor
Simulation and Speed Control of 3-Phase Induction Motor

... motors do not inherently have the capability of variable speed operation. Due to this reason, earlier dc motors were applied in most of the electrical drives. But the recent developments in speed control methods of the induction motor have led to their large scale use in almost all electrical drives ...
< 1 ... 1267 1268 1269 1270 1271 1272 1273 1274 1275 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report