• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A motor control center
A motor control center

... A direct on line starter can be used if the high inrush current of the motor does not cause excessive voltage drop in the supply circuit. The maximum size of a motor allowed on a direct on line starter may be limited by the supply utility for this reason. For example, a utility may require rural cus ...
DMS-20PC-0/1/2/8-DCM - Murata Power Solutions
DMS-20PC-0/1/2/8-DCM - Murata Power Solutions

... Simply connect a positive dc voltage across the rear terminals and the meters are fully operational — no additional components or power supplies are required! The large, 0.37"/9.4mm, LED displays can be easily read from 15 feet away. Four versions are available: +4.5019.99Vdc (0.01V resolution), +8. ...
Current in a transformer
Current in a transformer

www.ijecs.in International Journal Of Engineering And Computer Science ISSN:2319-7242
www.ijecs.in International Journal Of Engineering And Computer Science ISSN:2319-7242

Analog Voltage and Current Output Scaling
Analog Voltage and Current Output Scaling

CONDITIONS OF CERTIFICATION Instructions according to clause
CONDITIONS OF CERTIFICATION Instructions according to clause

... a. Additionally to the motor protecting switch the motor shall be monitored by the applicable temperature sensors in the stator windings in connection with a control unit which is suitable for this purpose or additionally to the motor protecting switch the motor shall be monitored by the thermal pro ...
Ultra Low Harmonic Drives
Ultra Low Harmonic Drives

moplt124
moplt124

Mechatronics Project 1 - NYU Tandon School of Engineering
Mechatronics Project 1 - NYU Tandon School of Engineering

Word - University of California, Berkeley
Word - University of California, Berkeley

... as the time it takes for the capacitor to charge up another 90%. This means, start at the current voltage and charge up 90% of the voltage difference (it is defined this way to make the general equation tractable). Assuming the effective resistance of an ‘ON’ transistor is R, consider again the two ...
Manual - Robot Marketplace
Manual - Robot Marketplace

... speed. The Uni range controllers are protected so that such failure is very unlikely but the constructor should consider what might happen in the event of such a fault and should consider fitting an emergency circuit breaker, relay, or battery disconnect switch or arrange the battery so it can quick ...
SET-326. Dual (active and standby) Lithium-ion battery
SET-326. Dual (active and standby) Lithium-ion battery

Subthreshold Voltage Operation of Benchmark Circuit c6288
Subthreshold Voltage Operation of Benchmark Circuit c6288

... From the graphs, we can infer that the optimum low voltage operating point is 0.4V which is just above the threshold voltage. Circuit still functions properly in subthreshold region and gives comparable energy savings to normal operation mode. More circuits need to be tested to check for subthreshol ...
TEMESCAL MODEL CV-6SLX ELECTRON BEAM POWER SUPPLY
TEMESCAL MODEL CV-6SLX ELECTRON BEAM POWER SUPPLY

SDC1-120-12-30 - IOTA Engineering
SDC1-120-12-30 - IOTA Engineering

... similar in appearance. You can recognize the Amplife Charge Control Module by the presence of the LED indicator on the face. ...
SDC1-120-12-75 - IOTA Engineering
SDC1-120-12-75 - IOTA Engineering

... similiar in appearance. You can recognize the Amplife Charge Control Module by the presence of the LED indicator on the face. ...
Experiment 9
Experiment 9

... for the circuit shown would be only about 5K. If a DC component is not desired in the oulput signal, a coupling capacitor may be used between the op-amp output and the load to block the DC. The AC voltage gain of this circuit is one, and the DC voltage gain is zero. We have a follower circuit that w ...
RB-Pol-214 12V Step-Up Voltage Regulator U3V12F12 Description
RB-Pol-214 12V Step-Up Voltage Regulator U3V12F12 Description

... These boost (step-up) voltage regulators generate higher output voltages from input voltages as low as 2.5 V. They are switching regulators (also called switched-mode power supplies (SMPS) or DC-to-DC converters) and have a typical efficiency between 80% to 90%. The available output current is a fun ...
A. Power from wind turbine
A. Power from wind turbine

JRW 70A single output series
JRW 70A single output series

... provides up to 70A output current in an industry standard half brick, which makes it an ideal choice for small space, high current and low voltage applications. The converter uses synchronous rectification technology and innovative packaging techniques to achieve ultra high efficiency reaching 91% a ...
T4000 Auto Synchronizer
T4000 Auto Synchronizer

... The limits for the closing signal are ­adjustable on the dial PHASE ANGLE. The phase can be adjusted between ±6° and ±9°, and voltage difference between ±10 % and ±15%. When the difference in voltage, phase and frequency are within limit for 0.5 seconds, a closing signal to the circuit breaker is ...
SDC1-120-24-25 - IOTA Engineering
SDC1-120-24-25 - IOTA Engineering

... similiar in appearance. You can recognize the Amplife Charge Control Module by the presence of the LED indicator on the face. ...
App Note 505 - Charging Units as Continuous DC Supplies
App Note 505 - Charging Units as Continuous DC Supplies

9.3.3 Generators
9.3.3 Generators

SDC1-120-24-40 - IOTA Engineering
SDC1-120-24-40 - IOTA Engineering

... similiar in appearance. You can recognize the Amplife Charge Control Module by the presence of the LED indicator on the face. ...
< 1 ... 1160 1161 1162 1163 1164 1165 1166 1167 1168 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report