
VF-0 series - Panasonic Electric Works
... The VF-CE inverter operator module keypad The operator module allows you to enter or change the VF-CE parameters as well as display the current drive parameters. The VF-CE parameters can be saved in the operator module (BFVC904C) and simply copied to another VF-CE inverter.Time-consuming parameter s ...
... The VF-CE inverter operator module keypad The operator module allows you to enter or change the VF-CE parameters as well as display the current drive parameters. The VF-CE parameters can be saved in the operator module (BFVC904C) and simply copied to another VF-CE inverter.Time-consuming parameter s ...
GSM15 Medical - SL Power Electronics
... SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 1/07. Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publicat ...
... SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 1/07. Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publicat ...
25471_energy_conversion_22
... SPEED CONTROL of SHUNT DC MOTOR • In previous figure (b) terminal characteristic of motor over full range from no-load to stall shown • In figure can see at very slow speeds, an increase in field resistance will actually decrease speed of motor • This effect occurs because at very low speeds, the i ...
... SPEED CONTROL of SHUNT DC MOTOR • In previous figure (b) terminal characteristic of motor over full range from no-load to stall shown • In figure can see at very slow speeds, an increase in field resistance will actually decrease speed of motor • This effect occurs because at very low speeds, the i ...
Induction Machine Speed Control
... possible to sell their products to a wider range of customers with different needs for example control of pumps and more powerful fans, so here it is important to minimize the losses created in the machine/motor. If possible they would also want to decrease the number of steps (time) needed in the p ...
... possible to sell their products to a wider range of customers with different needs for example control of pumps and more powerful fans, so here it is important to minimize the losses created in the machine/motor. If possible they would also want to decrease the number of steps (time) needed in the p ...
G201 INSTALLATION NOTES:
... revolution per second and then turn the trimpot until a distinct null is noted in the motor‟s vibration. This will result in the most even microstep placement for a given motor and power supply voltage. The default setting for this trimpot is at ½ -turn and the setting for your motor will be within ...
... revolution per second and then turn the trimpot until a distinct null is noted in the motor‟s vibration. This will result in the most even microstep placement for a given motor and power supply voltage. The default setting for this trimpot is at ½ -turn and the setting for your motor will be within ...
1 - Marine Institute
... A series R-L circuit consists of a 5006 resistor and a 2H inductor connected to a 120V, 60Hz source. Draw the circuit and: a) Calculate circuit impedance and current. (9056, 132.6mA) b) Sketch & label the impedance triangle and the phasor diagram. ( = 56.5°, VR = 66.3V, VL = 100V) ...
... A series R-L circuit consists of a 5006 resistor and a 2H inductor connected to a 120V, 60Hz source. Draw the circuit and: a) Calculate circuit impedance and current. (9056, 132.6mA) b) Sketch & label the impedance triangle and the phasor diagram. ( = 56.5°, VR = 66.3V, VL = 100V) ...
Current Transducer HOP 200 .. 600-SB I = 200 .. 600 A
... When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation.A prot ...
... When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation.A prot ...
SolarMax MT series
... feeds the grid with three-phase power and which gets more power out of each PV installation – whether it is a medium-size home installation or a major industrial project. A high input voltage reduces cable losses and expenses to a minimum. Thanks to the multi-tracking concept providing for as many a ...
... feeds the grid with three-phase power and which gets more power out of each PV installation – whether it is a medium-size home installation or a major industrial project. A high input voltage reduces cable losses and expenses to a minimum. Thanks to the multi-tracking concept providing for as many a ...
NMS Series - power, Murata
... ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to v ...
... ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to v ...
(10 Marks)(June 2013)
... • The switching regulator acts as a continuously variable power converter and hence its efficiency is negligibly affected by the voltage difference. hence the switching regulator is also known as “nondissipative regulator” in a SMPS, • The input DC supply is chopped at a higher frequency around 15 t ...
... • The switching regulator acts as a continuously variable power converter and hence its efficiency is negligibly affected by the voltage difference. hence the switching regulator is also known as “nondissipative regulator” in a SMPS, • The input DC supply is chopped at a higher frequency around 15 t ...
- Krest Technology
... PMSM is developed. A simple linearization procedure is employed to design linear state feedback controller (SFC). Digital redesign of SFC is carried out to achieve discrete form suitable for implementation in a DSP. Model predictive approach is used to a posteriori constraint introduction into contr ...
... PMSM is developed. A simple linearization procedure is employed to design linear state feedback controller (SFC). Digital redesign of SFC is carried out to achieve discrete form suitable for implementation in a DSP. Model predictive approach is used to a posteriori constraint introduction into contr ...
XGE fan speed controls
... no overheating and a longer product lifetime. In addition, XGE is fitted with an electro-magnetic suppression filter meeting the requirements of the CE and EMC directives. ...
... no overheating and a longer product lifetime. In addition, XGE is fitted with an electro-magnetic suppression filter meeting the requirements of the CE and EMC directives. ...
uniblock ubsf
... frequency of 60Hz. As this cannot be provided by the utilities, converters are employed which, on one hand, provide the necessary voltage and frequency, and on the other hand eliminate irregularities. PILLER has many years experience internationally in high-performance power systems. Based on the pr ...
... frequency of 60Hz. As this cannot be provided by the utilities, converters are employed which, on one hand, provide the necessary voltage and frequency, and on the other hand eliminate irregularities. PILLER has many years experience internationally in high-performance power systems. Based on the pr ...
Towards Zero Standby Power – Designers Get
... voltage is disconnected, CAPZero automatically discharges the X capacitor by connecting the bleed resistors in parallel. This operation allows total flexibility in the choice of the X capacitor to optimize differential mode EMI filtering and reduce inductor costs, with no effect on power consumpti ...
... voltage is disconnected, CAPZero automatically discharges the X capacitor by connecting the bleed resistors in parallel. This operation allows total flexibility in the choice of the X capacitor to optimize differential mode EMI filtering and reduce inductor costs, with no effect on power consumpti ...
A Comparative Study between Z-Source Inverter and Voltage
... exceed the dc-rail voltage the VSI is a buck (step-down) inverter. As upper and lower devices of each phase leg gated simultaneously either by any reason or by Electromagnetic Interference (EMI) noise causes a shoot-through problem which effect on reliability of inverter and dead time to block both ...
... exceed the dc-rail voltage the VSI is a buck (step-down) inverter. As upper and lower devices of each phase leg gated simultaneously either by any reason or by Electromagnetic Interference (EMI) noise causes a shoot-through problem which effect on reliability of inverter and dead time to block both ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.