Test - Yu Chun Keung Memorial College No. 2
... 3. A student wishes to construct a simple microammeter to measure small direct electric currents. A horse-shoe magnet with curved pole pieces is available and a light framework, or former, upon which to wind a coil. In addition there is a choice of two fibres, A and B, to suspend the coil, and a cho ...
... 3. A student wishes to construct a simple microammeter to measure small direct electric currents. A horse-shoe magnet with curved pole pieces is available and a light framework, or former, upon which to wind a coil. In addition there is a choice of two fibres, A and B, to suspend the coil, and a cho ...
Multi-Cell Lithium-Ion Battery Management System
... Pre - charge Constant Current stage Constant Current charging stage Constant voltage charging stage Voltage converter Boost converter circuit MSP430 Microcontroller ...
... Pre - charge Constant Current stage Constant Current charging stage Constant voltage charging stage Voltage converter Boost converter circuit MSP430 Microcontroller ...
Forming Mining Processing Plant Ore-Pulverizing Milldrive Starting
... © Research India Publications. http://www.ripublication.com thereon, resulting in longer startup, but it practically does not reduce the power needed for startup. The problem of the reduced torque on startup might be eliminated via starting by under-frequency relay. Power losses of the engine in thi ...
... © Research India Publications. http://www.ripublication.com thereon, resulting in longer startup, but it practically does not reduce the power needed for startup. The problem of the reduced torque on startup might be eliminated via starting by under-frequency relay. Power losses of the engine in thi ...
Presentation
... of hydropower plant is limited because large power plant will cause unpredictable environmental problem. Micro hydropower system is a flexible and environmental way of utilizing the hydropower sources considering its small sizes. Due to the simplified construction, micro hydropower system has no con ...
... of hydropower plant is limited because large power plant will cause unpredictable environmental problem. Micro hydropower system is a flexible and environmental way of utilizing the hydropower sources considering its small sizes. Due to the simplified construction, micro hydropower system has no con ...
a cockcroft–walton voltage multiplier fed by a three-phase-to
... CWVM to regulate the dc output voltage and smooth its ripple. With this flexible injection current, the performance of the proposed converter is superior to the conventional CWVM, which is usually energized by a single-phase ac source. The operation principle, control strategy, and design considerat ...
... CWVM to regulate the dc output voltage and smooth its ripple. With this flexible injection current, the performance of the proposed converter is superior to the conventional CWVM, which is usually energized by a single-phase ac source. The operation principle, control strategy, and design considerat ...
SUNNY CENTRAL 800CP XT / 850CP XT / 900CP XT
... The extended CP: peak output up to 1 megawatt For even more power: With its extended functions, the new Sunny Central CP XT series is now even more powerful. The reduced specific price, meaning that maximum yields are achieved with lower system costs. The Sunny Central CP XT is also optimized for co ...
... The extended CP: peak output up to 1 megawatt For even more power: With its extended functions, the new Sunny Central CP XT series is now even more powerful. The reduced specific price, meaning that maximum yields are achieved with lower system costs. The Sunny Central CP XT is also optimized for co ...
AN-1132 APPLICATION NOTE
... at 5 V—three times the output current. Therefore, the available load current decreases as the boost voltage increases. Boost converters use either voltage or current feedback to regulate the selected output voltage; the control loop enables the output to maintain regulation in response to load chang ...
... at 5 V—three times the output current. Therefore, the available load current decreases as the boost voltage increases. Boost converters use either voltage or current feedback to regulate the selected output voltage; the control loop enables the output to maintain regulation in response to load chang ...
Wind-RT™ LVRT Retrofit Solution
... Low voltage ride-through (RT) retrofit solution designed specifically for China China’s rapid growth to become the world leader in wind power installations has created significant challenges related to low voltage ride-through (LVRT) capabilities. Today, a large number of wind turbines in China need ...
... Low voltage ride-through (RT) retrofit solution designed specifically for China China’s rapid growth to become the world leader in wind power installations has created significant challenges related to low voltage ride-through (LVRT) capabilities. Today, a large number of wind turbines in China need ...
Field assessment of induction motor efficiency
... The equivalent circuit method is commonly used by manufacturers for large rotating machines having greater than NEMA frame sizes. The motor parameters, such as magnetization currents, leakage reactances, resistances, etc., are calculated and correlated with tests for specific voltages. The advantage ...
... The equivalent circuit method is commonly used by manufacturers for large rotating machines having greater than NEMA frame sizes. The motor parameters, such as magnetization currents, leakage reactances, resistances, etc., are calculated and correlated with tests for specific voltages. The advantage ...
EE 1183340
... Three-phase Induction motors have various advantages such as simple construction, reliable, rugged, low maintenance cost and lower manufacturing cost which has made induction motor popular to be used in many industrial applications. The major problem arises in this motor is their speed control as it ...
... Three-phase Induction motors have various advantages such as simple construction, reliable, rugged, low maintenance cost and lower manufacturing cost which has made induction motor popular to be used in many industrial applications. The major problem arises in this motor is their speed control as it ...
Motor and Pump Protection
... * 575 volt Model (MS 777-575) ** If J prefix is displayed in trip class setting, jam protection is enab led. *** If "oc" is disabled in the #RF setting, the o vercurrent will be included as a nor mal fault and the relay will automatically restart after RD2 expires,otherwise, manual reset is required ...
... * 575 volt Model (MS 777-575) ** If J prefix is displayed in trip class setting, jam protection is enab led. *** If "oc" is disabled in the #RF setting, the o vercurrent will be included as a nor mal fault and the relay will automatically restart after RD2 expires,otherwise, manual reset is required ...
VCO790-2560KY 数据资料DataSheet下载
... The information in this publication is believed to be accurate and reliable. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents, or other rights of third parties, resulting from its use. No license is granted by implication or ot ...
... The information in this publication is believed to be accurate and reliable. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents, or other rights of third parties, resulting from its use. No license is granted by implication or ot ...
Advanced VLSI Design - WSU EECS
... • Threshold voltage of both devices are increased by adjusting the body-bias voltage in order to reduce subthreshold leakage current in standby mode • Requires twin-tub technology so that substrates of individual devices can be adjusted ...
... • Threshold voltage of both devices are increased by adjusting the body-bias voltage in order to reduce subthreshold leakage current in standby mode • Requires twin-tub technology so that substrates of individual devices can be adjusted ...
AMS4122 数据手册DataSheet 下载
... AMS4122 is a dual switching regulator capable to deliver up to 2A for each channel. Internally Compensated internal Soft Start makes AMS4122 one of the simplest and easiest switching regulators to use with the minimum external components. Each regulator has independent hiccup current limit. The Enab ...
... AMS4122 is a dual switching regulator capable to deliver up to 2A for each channel. Internally Compensated internal Soft Start makes AMS4122 one of the simplest and easiest switching regulators to use with the minimum external components. Each regulator has independent hiccup current limit. The Enab ...
C 10:4X - Full Compass
... By offering an unmatched combination of channel density, operating efficiency and configuration flexibility, the C 10:4X presents convincing performance and cost-saving advantages. Applications include primary systems for theme parks, shopping malls, airports, hotels and restaurants as well as auxil ...
... By offering an unmatched combination of channel density, operating efficiency and configuration flexibility, the C 10:4X presents convincing performance and cost-saving advantages. Applications include primary systems for theme parks, shopping malls, airports, hotels and restaurants as well as auxil ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.