High-Powered Output Devices
... the driver • Deadtime: Turn one device off BEFORE turning the other on. Typical gaps: 50-200ns ...
... the driver • Deadtime: Turn one device off BEFORE turning the other on. Typical gaps: 50-200ns ...
Model Boat Electronics - Northwest R/C Ship Modelers
... For the Shelly Foss 36” using the Dumas “Pitman” motor is a good choice as you have power and long run times. See specs below: For the Dumas Chris Craft boats using a Graupner Speed 600 is a good choice as you have both power and speed. See specs below: Some suggestions as to where to purchase a new ...
... For the Shelly Foss 36” using the Dumas “Pitman” motor is a good choice as you have power and long run times. See specs below: For the Dumas Chris Craft boats using a Graupner Speed 600 is a good choice as you have both power and speed. See specs below: Some suggestions as to where to purchase a new ...
Power electronic converter technology
... Typical applications have been frequency converters for asynchronous motor drives and grid connected front-end converters, but also converters for subsea applications (e.g. hyberbaric welding machines). The group has expertise for managing the most important challenges in connection to converter des ...
... Typical applications have been frequency converters for asynchronous motor drives and grid connected front-end converters, but also converters for subsea applications (e.g. hyberbaric welding machines). The group has expertise for managing the most important challenges in connection to converter des ...
Full Article
... that are able to open and close contact in microseconds to nanosecond range (Kejuruteraan Bintai). Modern UPS system that is available nowadays, whether used in high power or low power application, records improvement from its ancestors. Most of the upgrades are done on the harmonics elimination, po ...
... that are able to open and close contact in microseconds to nanosecond range (Kejuruteraan Bintai). Modern UPS system that is available nowadays, whether used in high power or low power application, records improvement from its ancestors. Most of the upgrades are done on the harmonics elimination, po ...
auto bridge revised - Sivananda Electronics
... Tanδ Test Set Useful for condition monitoring insulation tests for power sector equipments such as High Voltage (EHV) class Bushings, Windings of transformer ...
... Tanδ Test Set Useful for condition monitoring insulation tests for power sector equipments such as High Voltage (EHV) class Bushings, Windings of transformer ...
a single-phase cascaded multilevel inverter
... is comprised of a series connection of the proposed basic unit and is able to only generate positive levels at the output. Therefore, an H-bridge is added to the proposed inverter. This inverter is called the developed cascaded multilevel inverter. In order to generate all voltage levels (even and o ...
... is comprised of a series connection of the proposed basic unit and is able to only generate positive levels at the output. Therefore, an H-bridge is added to the proposed inverter. This inverter is called the developed cascaded multilevel inverter. In order to generate all voltage levels (even and o ...
DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC
... disconnection switch must be mounted in close proximity to the operator’s start/stop controls. This is required, as the DC3 drive does not have an armature loop contactor. A single fault like a power device short may cause motor rotation when in the stop mode. The user is responsible for assuring sa ...
... disconnection switch must be mounted in close proximity to the operator’s start/stop controls. This is required, as the DC3 drive does not have an armature loop contactor. A single fault like a power device short may cause motor rotation when in the stop mode. The user is responsible for assuring sa ...
Starting Time Calculation for Induction Motor
... the heavy applications requirement. Some are considered large even in comparison to the total capacity of large industrial power systems. Starting of such large motors can cause adverse effects to any locally connected load, other motors and also to buses, which are electrically remote from the poin ...
... the heavy applications requirement. Some are considered large even in comparison to the total capacity of large industrial power systems. Starting of such large motors can cause adverse effects to any locally connected load, other motors and also to buses, which are electrically remote from the poin ...
PREOBRAZOVATEL
... continuous record time more than 20 sec while recording all channels with max sampling rate; recording of all recorder settings to non-volatile memory; possibility of analog signals scales changing by scaling factor input for each channel and zero offset setting; inbuilt non-volatile clock ( ...
... continuous record time more than 20 sec while recording all channels with max sampling rate; recording of all recorder settings to non-volatile memory; possibility of analog signals scales changing by scaling factor input for each channel and zero offset setting; inbuilt non-volatile clock ( ...
DC Generators Separate and Shunt Excitation
... The method of excitation profoundly influences both the steady-state characteristics and the dynamic behavior of the machine in control systems. The connection diagram of a separately excited generator is given in Fig. 1a. The required field current is a very small fraction of the rated armature cur ...
... The method of excitation profoundly influences both the steady-state characteristics and the dynamic behavior of the machine in control systems. The connection diagram of a separately excited generator is given in Fig. 1a. The required field current is a very small fraction of the rated armature cur ...
Bartłomiej Kamiński, Marcin Nikoniuk, Łukasz Drązikowski
... plate can be constructed with solid or ladder cut aluminium or copper. If a ladder type reaction plate is used instead of solid, performance and efficiency of the motor are improved at the increased cost of the secondary winding manufacturing. Application of this type of the propulsion provides foll ...
... plate can be constructed with solid or ladder cut aluminium or copper. If a ladder type reaction plate is used instead of solid, performance and efficiency of the motor are improved at the increased cost of the secondary winding manufacturing. Application of this type of the propulsion provides foll ...
PowerPal Brochure
... The BPC PowerPal™ range of UPS will provide clean and reliable backup power to ensure continued data integrity and optimum file server performance under a wide range of mains power conditions. Our advanced power management and diagnostic software package PowerSmart™ is also available, this will allo ...
... The BPC PowerPal™ range of UPS will provide clean and reliable backup power to ensure continued data integrity and optimum file server performance under a wide range of mains power conditions. Our advanced power management and diagnostic software package PowerSmart™ is also available, this will allo ...
AC POWER TRANSFER SWITCH PMTS-30 and PMTS
... When L1 and L2 (rated for 35 A each) are connected in phase, generator-neutral capability will increase up to 70 A All field wires used have to be rated for at least 105° C. For 6 to 14 AWG wires, use 13 inch-pound torque. Ground terminal bar is suitable for 6-14 AWG conductors using 35 inch-pounds ...
... When L1 and L2 (rated for 35 A each) are connected in phase, generator-neutral capability will increase up to 70 A All field wires used have to be rated for at least 105° C. For 6 to 14 AWG wires, use 13 inch-pound torque. Ground terminal bar is suitable for 6-14 AWG conductors using 35 inch-pounds ...
Power Electronics
... KV and 4 KA. Its switching frequency of about 25 KHz and ease of connection and drive saw it totally removing the Bipolar from practically all applications. Industrially, only the MOSFET has been able to continue in the sub – 10 KVA range primarily because of its high switching frequency. The IGBT h ...
... KV and 4 KA. Its switching frequency of about 25 KHz and ease of connection and drive saw it totally removing the Bipolar from practically all applications. Industrially, only the MOSFET has been able to continue in the sub – 10 KVA range primarily because of its high switching frequency. The IGBT h ...
Hybrid switches for low-voltage DC grids
... solar power systems are the most prominent renewable power source for these buildings [2]. The solar cells of solar power systems generate DC current and interestingly lighting, energy efficient building heating, ventilation, air-condition and cooling as well as computer of information technology ar ...
... solar power systems are the most prominent renewable power source for these buildings [2]. The solar cells of solar power systems generate DC current and interestingly lighting, energy efficient building heating, ventilation, air-condition and cooling as well as computer of information technology ar ...
EE20 RC_RJIT Conference
... This advance topology generates large number of voltage levels with the minimum number of switches. The proposed topology also reduces the total harmonic distortion (THD) of its output waveform. This paper also represent circuit configuration, theoretical operation and MATLAB based simulation result ...
... This advance topology generates large number of voltage levels with the minimum number of switches. The proposed topology also reduces the total harmonic distortion (THD) of its output waveform. This paper also represent circuit configuration, theoretical operation and MATLAB based simulation result ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.