
parametric study of rotor slot shape on a cage induction motor
... Usually the rotor slots geometry can be considered as an independent design parameter [1]. Nowadays, with the computing tools based on the numerical analysis, it is possible the redesigning of the rotor slots to improve the electromagnetic performance of squirrel cage induction motors without signif ...
... Usually the rotor slots geometry can be considered as an independent design parameter [1]. Nowadays, with the computing tools based on the numerical analysis, it is possible the redesigning of the rotor slots to improve the electromagnetic performance of squirrel cage induction motors without signif ...
Coaxial Cable Protection
... A gas tube lightning protector can be considered a very fast switch. Whenever a given threshold voltage is exceeded across the “switch” it will turn “on” and handle a large current pulse for a short duration. When the voltage falls back below the turn on threshold, the “switch” will “open” again all ...
... A gas tube lightning protector can be considered a very fast switch. Whenever a given threshold voltage is exceeded across the “switch” it will turn “on” and handle a large current pulse for a short duration. When the voltage falls back below the turn on threshold, the “switch” will “open” again all ...
Implementation of a Digital Signal Processor
... Summary: This paper presents the implementation of an active filter configuration for harmonic compensation. The system can be controlled for current harmonics and reactive power compensations simultaneously by using a converter operating as active shunt filter. A synchronous reference frame based c ...
... Summary: This paper presents the implementation of an active filter configuration for harmonic compensation. The system can be controlled for current harmonics and reactive power compensations simultaneously by using a converter operating as active shunt filter. A synchronous reference frame based c ...
The key to unlocking your efficiency potential
... Side-by-side or horizontal mounting, – Saves panel space and cost without derating – Saves cost for external cooling and reduces Operates at up to 45 °C without derating downtime for overtemperature failures ...
... Side-by-side or horizontal mounting, – Saves panel space and cost without derating – Saves cost for external cooling and reduces Operates at up to 45 °C without derating downtime for overtemperature failures ...
2SB1707
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
Multilayer Varistor General Information
... Minimum resistance between shorted terminals and varistor surface. The maximum peak voltage that may be applied under continuous operating conditions between the varistor terminations and any conducting mounting surface. The range of ambient temperature for which the varistor is designed to operate ...
... Minimum resistance between shorted terminals and varistor surface. The maximum peak voltage that may be applied under continuous operating conditions between the varistor terminations and any conducting mounting surface. The range of ambient temperature for which the varistor is designed to operate ...
Lecture1_26.09.2013
... are related—the propagation delay is mostly determined by the speed at which a given amount of energy can be stored on the gate capacitors. • The product of power consumption and propagation delay is generally a constant. This product is called the power-delay product (or PDP) and can be considered ...
... are related—the propagation delay is mostly determined by the speed at which a given amount of energy can be stored on the gate capacitors. • The product of power consumption and propagation delay is generally a constant. This product is called the power-delay product (or PDP) and can be considered ...
A - C SUBMERSIBLE PUMP TEST
... 1b. Test the resistance to ground (minimum 100 megohms). Do not record any reading of less than 100 megohms without first testing the motor with the plug disconnected. If the low megohms are due to poor insulation in the plug, change the plug and proceed with the test. To make this test, close the ci ...
... 1b. Test the resistance to ground (minimum 100 megohms). Do not record any reading of less than 100 megohms without first testing the motor with the plug disconnected. If the low megohms are due to poor insulation in the plug, change the plug and proceed with the test. To make this test, close the ci ...
Variable Frequency Drives - MD Anderson Cancer Center
... A. All materials shall meet or exceed all applicable referenced standards, federal, state and local requirements, and conform to codes and ordinances of authorities having jurisdiction. B. Furnish complete VFD controllers that convert incoming fixed frequency three-phase AC power into a variable fre ...
... A. All materials shall meet or exceed all applicable referenced standards, federal, state and local requirements, and conform to codes and ordinances of authorities having jurisdiction. B. Furnish complete VFD controllers that convert incoming fixed frequency three-phase AC power into a variable fre ...
Power Conversion Systems
... a cabinet. Screw type mating connectors are supplied with the module. Due to the limited number of connector pins this option is not available for modules with dual AC input or for multi-output converters with output 4 supplying more than 10 A. ...
... a cabinet. Screw type mating connectors are supplied with the module. Due to the limited number of connector pins this option is not available for modules with dual AC input or for multi-output converters with output 4 supplying more than 10 A. ...
AD8629S: Zero-Drift, Single-Supply Rail-to-Rail Input/Output Operational Amplifier Aerospace Data Sheet (Rev E, 10/2012)
... The AD8629 is a single-supply, ultrahigh precision rail-to-rail input and output operational amplifier. The typical offset voltage of less than 1 μV allows this amplifier to be easily configured for high gains without risk of excessive output voltage errors. The extremely small temperature drift ens ...
... The AD8629 is a single-supply, ultrahigh precision rail-to-rail input and output operational amplifier. The typical offset voltage of less than 1 μV allows this amplifier to be easily configured for high gains without risk of excessive output voltage errors. The extremely small temperature drift ens ...
starters and circle diagram for Induction motor File
... squirrel cage induction motors. It directly connects the contacts of the motor to the full supply voltage. The starting current is very large, normally 6 to 8 times the rated current. The starting torque is likely to be 0.75 to 2 times the full load torque. In order to avoid excessive voltage drops ...
... squirrel cage induction motors. It directly connects the contacts of the motor to the full supply voltage. The starting current is very large, normally 6 to 8 times the rated current. The starting torque is likely to be 0.75 to 2 times the full load torque. In order to avoid excessive voltage drops ...
ABB string inverters PVI-10.0-I
... PVI-10.0, isolated, three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. The dual Multiple Power Point Tracker (MPPT) maximizes energy production and increases design flexibility. This dual indepen ...
... PVI-10.0, isolated, three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. The dual Multiple Power Point Tracker (MPPT) maximizes energy production and increases design flexibility. This dual indepen ...
FLUKE Test Equipment
... • Calculates 3-phase power on balanced loads, from a single-phase measurement • Measures power harmonics, and captures voltage sags, transients and inrush current • Monitoring functions help track intermittent problems and power system performance • Menus use familiar electrical terminology • Toggle ...
... • Calculates 3-phase power on balanced loads, from a single-phase measurement • Measures power harmonics, and captures voltage sags, transients and inrush current • Monitoring functions help track intermittent problems and power system performance • Menus use familiar electrical terminology • Toggle ...
Submission Format for IMS2004 (Title in 18
... For three-phase AC which is the output of the TLG-500 six diodes (three pairs) are used. Each pair of diodes is connected in series, anode to cathode. Commercially available diodes typically have four terminals so they can be configured for single-phase split supply, half bridge or three-phase use. ...
... For three-phase AC which is the output of the TLG-500 six diodes (three pairs) are used. Each pair of diodes is connected in series, anode to cathode. Commercially available diodes typically have four terminals so they can be configured for single-phase split supply, half bridge or three-phase use. ...
VT 6030-120 - Ventex Tech
... 1. Contact with the transformer’s high voltage output leads can cause shock, burn or death. 2. Do not use two wire extension cords or cut the ground pin to fit a two wire power outlet. The third prong of the power cord must be connected to ground. Removal of third pin ground plug voids UL Listing ...
... 1. Contact with the transformer’s high voltage output leads can cause shock, burn or death. 2. Do not use two wire extension cords or cut the ground pin to fit a two wire power outlet. The third prong of the power cord must be connected to ground. Removal of third pin ground plug voids UL Listing ...
4035
... Crystal Displays (LCDs). The LCD display is used in laptop computers, gas pumps, automobiles, test equipment, PDAs and medical instruments. CCFLs are small, efficient and inexpensive. The lamp must be driven by a specialized power supply. High sinusoidal AC voltage is needed to start the lamps, but ...
... Crystal Displays (LCDs). The LCD display is used in laptop computers, gas pumps, automobiles, test equipment, PDAs and medical instruments. CCFLs are small, efficient and inexpensive. The lamp must be driven by a specialized power supply. High sinusoidal AC voltage is needed to start the lamps, but ...
Variable Frequency Drives
... equipment, not current distortion! • 5% reactors address 90+% of typical applications. They also provide protection against line transients and keep input currents low to avoid oversizing power wiring to comply with NEC. • Make VFD vendor perform a harmonic distortion calculation with the submittals ...
... equipment, not current distortion! • 5% reactors address 90+% of typical applications. They also provide protection against line transients and keep input currents low to avoid oversizing power wiring to comply with NEC. • Make VFD vendor perform a harmonic distortion calculation with the submittals ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.