CA3160 - Experimentalists Anonymous
... transistor Q11 and its cascode-connected load resistance provided by PMOS transistors Q3 and Q5. The source of bias potentials for these PMOS transistors is described later. Miller Effect compensation (roll off) is accomplished by means of the 30pF capacitor and 2kΩ resistor connected between the ba ...
... transistor Q11 and its cascode-connected load resistance provided by PMOS transistors Q3 and Q5. The source of bias potentials for these PMOS transistors is described later. Miller Effect compensation (roll off) is accomplished by means of the 30pF capacitor and 2kΩ resistor connected between the ba ...
S1-3-15 - Series vs. Parallel
... http://explorelearning.com/index.cfm?method=cResource.dspView&ResourceID=398&CFID=65 9338&CFTOKEN=31765817 ...
... http://explorelearning.com/index.cfm?method=cResource.dspView&ResourceID=398&CFID=65 9338&CFTOKEN=31765817 ...
RC Filter Networks
... This experiment aims to examine the response of R-C filter networks to sinusoidal signals of various frequencies, and to various square waves. In particular, the highpass and low-pass circuits will be investigated. Basic Theory and Equations: The high-pass filter consists of a capacitor and resistor ...
... This experiment aims to examine the response of R-C filter networks to sinusoidal signals of various frequencies, and to various square waves. In particular, the highpass and low-pass circuits will be investigated. Basic Theory and Equations: The high-pass filter consists of a capacitor and resistor ...
section 16055 - overcurrent protective device coordination
... Recommended Device Settings: Include tabulated settings for each adjustable device. a. Device tag. b. Relay tap, time-dial, and instantaneous settings. c. Circuit breaker sensor rating, long-time, short time, I2T, and instantaneous settings. d. Circuit breaker ground fault pickup and time delay sett ...
... Recommended Device Settings: Include tabulated settings for each adjustable device. a. Device tag. b. Relay tap, time-dial, and instantaneous settings. c. Circuit breaker sensor rating, long-time, short time, I2T, and instantaneous settings. d. Circuit breaker ground fault pickup and time delay sett ...
Application Note: Sizing Three-Phase Inverters for Single
... Although Hitachi does not offer inverters above 3 hp specifically sized and rated for single-phase operation, single-phase power can be safely used with larger 3-phase rated inverters, provided that care is taken to properly upsize and apply the inverter. As background, for a given power (kW/hp) and ...
... Although Hitachi does not offer inverters above 3 hp specifically sized and rated for single-phase operation, single-phase power can be safely used with larger 3-phase rated inverters, provided that care is taken to properly upsize and apply the inverter. As background, for a given power (kW/hp) and ...
AC GUI Stand Alone
... When we press the “Generate *.H files” button the GUI create config.h and MTCParam.h, with the current settings used, to be included into software AC induction motor library to make an executable stand alone software that can be used without connection with the PC. ...
... When we press the “Generate *.H files” button the GUI create config.h and MTCParam.h, with the current settings used, to be included into software AC induction motor library to make an executable stand alone software that can be used without connection with the PC. ...
FSQ500L Compact, Green Mode, Fairchild Power Switch (FPS™) Features
... thermal shutdown (TSD). While OLP is implemented as auto-restart mode, there is no switching when TSD triggers. Once the overload condition is detected, switching is terminated, the senseFET remains off, and HV/REG turns off. This causes VCC to fall. When VCC falls below the under voltage lockout (U ...
... thermal shutdown (TSD). While OLP is implemented as auto-restart mode, there is no switching when TSD triggers. Once the overload condition is detected, switching is terminated, the senseFET remains off, and HV/REG turns off. This causes VCC to fall. When VCC falls below the under voltage lockout (U ...
ppt - ECE Users Pages
... Vout = Rf(I1 + I2 + I3 + … + IN) where the currents I1, I2, I3, ... are binary weighted currents. ...
... Vout = Rf(I1 + I2 + I3 + … + IN) where the currents I1, I2, I3, ... are binary weighted currents. ...
Rail-to-Rail Output Audio Amplifiers SSM2275/SSM2475*
... REV. 0 Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or ot ...
... REV. 0 Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or ot ...
MP1470H - Monolithic Power System
... The MP1470H has three working modes: AAM (Advanced Asynchronous Modulation) mode, DCM (Discontinues-Conduction Mode) and CCM (Continues-Conduction Mode). The device will operate from AAM mode, DCM to CCM with the load current increasing. AAM Control Operation In the light load condition, MP1470H wor ...
... The MP1470H has three working modes: AAM (Advanced Asynchronous Modulation) mode, DCM (Discontinues-Conduction Mode) and CCM (Continues-Conduction Mode). The device will operate from AAM mode, DCM to CCM with the load current increasing. AAM Control Operation In the light load condition, MP1470H wor ...
RURD660S9A_F085 Ultrafast Power Rectifier, 6A 600V RURD660S9A_F085 Ultrafas Features
... • Switching Mode Power Supply • Power switching circuits ...
... • Switching Mode Power Supply • Power switching circuits ...
MAX16963 Dual 2.2MHz, Low-Voltage Step-Down DC-DC Converter General Description
... Device Supply Voltage Input. Bypass with at least a 1FF ceramic capacitor to GND. In addition, connect a 10I decoupling resistor between PV and the bypass capacitor. ...
... Device Supply Voltage Input. Bypass with at least a 1FF ceramic capacitor to GND. In addition, connect a 10I decoupling resistor between PV and the bypass capacitor. ...
Application of VFD in Condenser Pumps in Thermal Power Plant 1
... stably for 2 years with obvious energy saving effect. 2. Operating Mode of Condenser Pumps The steam finished working in the turbine, will condense in the condenser, it is collected in the hot water well. The function of the condenser pump is to pump the condensed water into the deaerator in time. T ...
... stably for 2 years with obvious energy saving effect. 2. Operating Mode of Condenser Pumps The steam finished working in the turbine, will condense in the condenser, it is collected in the hot water well. The function of the condenser pump is to pump the condensed water into the deaerator in time. T ...
BDTIC www.BDTIC.com/infineon RF and Protection Devices BCR450, TDA4863
... In general, the upper limit on output current for this circuit is only limited by the maximum power dissipation & junction temperature of the boost transistor. It is even possible to parallel multiple boost transistors for extremely high current operation. ...
... In general, the upper limit on output current for this circuit is only limited by the maximum power dissipation & junction temperature of the boost transistor. It is even possible to parallel multiple boost transistors for extremely high current operation. ...
(CCM) and Discontinuous Conduction Mode (DCM)
... Boundary the inductor current, iL, just reaches zero and tries to go negative but the circuit diodes will not allow it. We now write expressions for the inductor current Green Technology and Productivity ...
... Boundary the inductor current, iL, just reaches zero and tries to go negative but the circuit diodes will not allow it. We now write expressions for the inductor current Green Technology and Productivity ...
NAG8152-DPM3 Netzanschaltgerät
... On the display, various information pages can be viewed by using the left and right buttons. The test voltage and power can be seen in these pages. The correct installation of the CTs can only be verified by checking the power factor only if the current flows. If this is zero, then the CT has been i ...
... On the display, various information pages can be viewed by using the left and right buttons. The test voltage and power can be seen in these pages. The correct installation of the CTs can only be verified by checking the power factor only if the current flows. If this is zero, then the CT has been i ...
KE2316991705
... Fig. 5 illustrates the output current-flow diagram of the secondary side under the normal operation and Fig. 6 shows the zero-phase-sequence equivalent circuit, where the battery is operating at discharge mode. In Fig. 5, the secondary side functions as a conventional three-phase inverter with a mot ...
... Fig. 5 illustrates the output current-flow diagram of the secondary side under the normal operation and Fig. 6 shows the zero-phase-sequence equivalent circuit, where the battery is operating at discharge mode. In Fig. 5, the secondary side functions as a conventional three-phase inverter with a mot ...
a Ultralow Noise, High Speed, BiFET Op Amp AD745
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to Ab ...
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to Ab ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.