• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Dynamic Load Modelling of Some Low Voltage
Dynamic Load Modelling of Some Low Voltage

... Dynamic Load Modelling of Some Low Voltage Devices Lidija M. Korunović and Dobrivoje P. Stojanović Abstract: This paper presents the results of dynamic load modelling for some frequently used low voltage devices. The modelling of long-term dynamics is performed on the basis of step changes of supp ...
one-phase static meters ze 110
one-phase static meters ze 110

... optical head applied to the defined place on the meter housing. Its electric input/output is RS 232 interface for connection to a PC port or to a connector of a portable terminal. If required, even units with electromechanical counters can be equipped with optical interfaces. ...
ADM222 数据手册DataSheet 下载
ADM222 数据手册DataSheet 下载

... The receivers are inverting level-shifters that accept RS-232 input levels (± 3 V to ± 15 V) and translate them into 5 V TTL/ CMOS levels. The inputs have internal 5 kΩ pull-down resistors to ground and are also protected against overvoltages of up to ± 30 V. The guaranteed switching thresholds are ...
Simple EL84 Basic layout
Simple EL84 Basic layout

... sensing resistor. It should read ~40mV. Both tubes on each channel should draw the same amount. If current draw is different, adjust 500 ohm pot. Be careful that you don’t touch any high voltage points. When both tubes conduct same amount of current (+/-5mA), you are ready to play! ...
LT6210/LT6211 - Single/Dual Programmable Supply Current, R-R Output, Current Feedback Amplifiers
LT6210/LT6211 - Single/Dual Programmable Supply Current, R-R Output, Current Feedback Amplifiers

... Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: As long as output current and junction temperature are kept below the absolute maximum ratings, no damage to the part will occur. Depending on the supply voltage, a heat sink may be required. Note 3: Th ...
Evaluates: MAX1960/MAX1961/MAX1962 MAX1960 Evaluation Kit General Description Features
Evaluates: MAX1960/MAX1961/MAX1962 MAX1960 Evaluation Kit General Description Features

... installed, but can also be used to evaluate the MAX1961 and the MAX1962. Free samples of these parts can be obtained from Maxim. To evaluate the MAX1961, first carefully remove U1 from the PC board and replace it with the MAX1961. Next, remove feedback resistors R3 and R4. Finally, short the pads of ...
download
download

Third Harmonic Injection Technique
Third Harmonic Injection Technique

Module 27: Hydrogen Production by Electrolysis with a Fuel Cell
Module 27: Hydrogen Production by Electrolysis with a Fuel Cell

... To be in electrolysis mode, the voltage must be greater than the voltage corresponding to zero current. This voltage is called the open circuit voltage, EOCV, and in Figure 3 has a value of 1.2 V. The hydrogen reaction rate is directly proportional to the current, since for each hydrogen molecule th ...


... loaded, it creates a higher harmonic content than at full load. A swing choke increases its inductance when the current passing through it is lower, usually due to partial loading. This increased inductance reduces the harmonics as a percent of load current. ...
SN65HVD179 数据资料 dataSheet 下载
SN65HVD179 数据资料 dataSheet 下载

... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absol ...
TPS61021A 3-A Boost Converter with 0.5
TPS61021A 3-A Boost Converter with 0.5

... switching and turns on the high side PMOS FET. The device works in pass-through mode. The output voltage is the input voltage minus the voltage drop across the dc resistance (DCR) of the inductor and the on-resistance (RDS(on)) of the PMOS FET. When the output voltage drops below the 98% of the sett ...
Electrical Safety Related Work Practices
Electrical Safety Related Work Practices

... Should a portion of your job require you to actually work on and test electrical systems and components, then you will also need to be trained in the following course: NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces -- A Operational Guide for Protection Against Shock an ...
Electronic Components That Breakdown When Under Full Operating
Electronic Components That Breakdown When Under Full Operating

Aalborg Universitet
Aalborg Universitet

Current and Circuits - juan
Current and Circuits - juan

... Current and Circuits Diagramming Circuits An ammeter measures current and a voltmeter measures potential differences. Each instrument has two terminals, usually labeled + and –. A voltmeter measures the potential difference across any component of a circuit. When connecting the voltmeter in a circui ...
Lab 8 - Rose
Lab 8 - Rose



... you recorded at each of the various generator loading conditions in part c. Using your motor constant K, determine the value of the back-emf speed voltage at each recorded speed. Determine the voltage across the motor resistance at each speed. Use this value and the measured currents to calculate th ...
Battery Tender Junior 12 Volt or 6 Volt Single
Battery Tender Junior 12 Volt or 6 Volt Single

SED1335F - Electrical and Information Technology
SED1335F - Electrical and Information Technology

... The SED1335F is a graphics and character display controller for use with medium scale dot matrix LCDs. The SED1335F generates all the signals required by the display memory and LCD drivers, and incorporates a character generator ROM, so that flexible, low power, display systems can be designed with ...
Employ ammeter shunts and voltage multipliers
Employ ammeter shunts and voltage multipliers

Evaluates:  MAX17007A MAX17007A Evaluation Kit General Description Features
Evaluates: MAX17007A MAX17007A Evaluation Kit General Description Features

... more details. Table 4 also lists the JU1 and JU2 jumper configurations for each output-voltage type. Adjustable Voltage The OUT1 output voltage can be adjusted up to 2V by applying a DC voltage (0 to 2V) to the REFIN1 test point. When OUT1 is used as an adjustable output voltage, remove the shunt fr ...
Tamura Open Loop Hall Effect Current Sensors
Tamura Open Loop Hall Effect Current Sensors

... seven rated currents ranging from 3A to 30A and PSU options of +5VDC and ±15VDC. The features include single and dual power supply operation, good accuracy (~1%) and fast response time (≤ 5ųSec). The L07P series is PCB mounted with a multi-turn integrated primary conductor rated up to 30A. The L07P ...
VRM Thesis - bgavinsound.com
VRM Thesis - bgavinsound.com

... The most common power converter topology is the buck power converter, sometimes called a step down power converter. Power supply designers choose the buck power converter because the output voltage is always less than the input voltage in the same polarity and is not isolated from the input. ...
Wideband Complementary Current Output DAC
Wideband Complementary Current Output DAC

... While this design may still yield acceptable results in the application, it is a simple matter to adjust these resistor values slightly to get perfect gain match from the two output currents to the amplifier output and also provide exactly the same apparent resistive load to each output. Implementin ...
< 1 ... 557 558 559 560 561 562 563 564 565 ... 1441 >

Current source



A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report