• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Model 1900 Manual
Model 1900 Manual

... (e.g. by shorting the input to ground, or with a low TTL signal), the polarization voltage is turned off, and the voltage at the polarographic electrode is set to the same potential as the reference electrode. The polarization voltage available at MONITOR OUT reflects the state of the signal at GATE ...
LT3012 - 250mA, 4V to 80V Low Dropout
LT3012 - 250mA, 4V to 80V Low Dropout

... SHDN pin can be driven either by 5V logic or open-collector logic with a pull-up resistor. The pull-up resistor is only required to supply the pull-up current of the open-collector gate, normally several microamperes. If unused, the SHDN pin must be tied to a logic high or to VIN. IN (Pins 10, 11)/( ...
Voltright - Sollatek
Voltright - Sollatek

... controlled by installing a Sollatek SVS on the power lines which supply the cold room equipment. When to use a Sollatek voltage Stabiliser (SVS) The Sollatek Voltage Stabiliser (SVS) is strongly recommended in the following situations where, for example: • A new vaccine cold room is being installed ...
AN2794
AN2794

... The converter is fed by a low DC input voltage varying from 20 V to 28 V and is capable of supplying up to 1 kW output power on a single-phase AC load. These features are possible thanks to a dual stage conversion topology including an efficient step-up push-pull DC-DC converter, to produce a regula ...
Pearl Street Lab
Pearl Street Lab

... The purpose of this lab is to illustrate the advantage of using high-resistance light bulbs in a power transmission system. The lab simulates Edison’s (and the world’s) first important transmission system, the Pearl Street Power Plant in New York City. The Pearl Street plant provided the power to il ...
TR41.9.2-04-05-012-MR1-OPS-voltage
TR41.9.2-04-05-012-MR1-OPS-voltage

... station equipment. A network private line facility connects the OPS line circuit with the remote station equipment. Thus, there are two network interfaces, one at each end of the private line facility. Approved station equipment is used as the off premises station. The hazardous voltage requirements ...
FEATURES DESCRIPTION D
FEATURES DESCRIPTION D

... (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. (2) ...
976-Support for Non-Specialists Teaching Physics ( Electricity )
976-Support for Non-Specialists Teaching Physics ( Electricity )

True RMS Multimeter with IR Thermometer
True RMS Multimeter with IR Thermometer

TL431A-Q1 数据资料 dataSheet 下载
TL431A-Q1 数据资料 dataSheet 下载

... (die substrate) and should be floating or connected to ANODE. TL431, TL431A, TL431B DBZ (SOT-23-5) PACKAGE (TOP VIEW) ...
Evaluates:  MAX8857A MAX8857A Evaluation Kit General Description Features
Evaluates: MAX8857A MAX8857A Evaluation Kit General Description Features

... 5) Turn on the 2.4V power supply. 6) Verify that the voltage across the VSU and GND pads is 5V. Connect a load, if desired, from VSU to GND. See Table 1 for output current. 7) Verify that the voltage across the VM and GND pads is 3.3V. Connect a load, if desired, from VM to GND. See Table 1 for outp ...
dc voltage measurements
dc voltage measurements

2016 China International Conference on Electricity Distribution
2016 China International Conference on Electricity Distribution

MNX SERIES High Voltage Power Supply
MNX SERIES High Voltage Power Supply

chapter 1 - e-CRiM - Politeknik Tuanku Sultanah Bahiyah
chapter 1 - e-CRiM - Politeknik Tuanku Sultanah Bahiyah

DMMT3904W Features Mechanical Data
DMMT3904W Features Mechanical Data

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
AP3968/69/70 Description Applications
AP3968/69/70 Description Applications

... the switching pulse, a typical 500ns leading edge blanking is built in. During this blanking period, the current sense comparator is disabled and the gate driver cannot be switched off. The built-in LEB in AP3968/69/70 has shorter delay time from current sense terminal to output pulse than those IC ...
FG Marx paperv4 - Quercus Technical Services
FG Marx paperv4 - Quercus Technical Services

BD9329AEFJ
BD9329AEFJ

485 LaserPak User's Manual
485 LaserPak User's Manual

... and voltage limits as appropriate for your device. You will typically want the limits to be 10% or more above the operation limits of your device. When setting the voltage limit, take into account the voltage loss in the cable, which can amount to several tenths of a volt at higher currents. When fi ...
160 and 80 Meter Matching Network for Your 43 foot Vertical
160 and 80 Meter Matching Network for Your 43 foot Vertical

...  Part 1, I described a simple 160 and ing on all bands from 160 to 10 meters. A on these bands. This keeps the unun second80 meter base matching assembly for 2.1 × 5.5 mm dc power jack located below the ary voltage reasonable, and the feed line and a 43 foot antenna. While that unit SO-239 connector ...
Four Point Probe
Four Point Probe

... In order to measure the resistivity of a substance, four points of contact must be made with the probe and the substance. Current goes through the two outer probes, and the difference in voltage is measured between the two inner probes. Through this process the resistance can be calculated. ...
Time relay, 2-off 1/2 The unit consists of two printed circuit boards
Time relay, 2-off 1/2 The unit consists of two printed circuit boards

... The time period of the relay with switch-on delay can be infinitely adjusted via the rotary knob of the potentiometer. The contact set consists of two normally open contacts and two normally closed contacts. When the voltage is applied to the coil connections, the set time delay takes effect. When t ...
Advantage of the use of an added driver source lead in discrete
Advantage of the use of an added driver source lead in discrete

... RGATE is changed, accelerating or delaying the switching operations. Figure 15. Turn-off energy comparison @ different Rg values ...
SN75ALS161 数据资料 dataSheet 下载
SN75ALS161 数据资料 dataSheet 下载

... The SN75ALS161 device features eight driver-receiver pairs connected in a front-to-back configuration to form input/output (I/O) ports at both the bus and terminal sides. The direction of data through these driver-receiver pairs is determined by the direction-control (DC) and talk-enable (TE) signal ...
< 1 ... 498 499 500 501 502 503 504 505 506 ... 1441 >

Current source



A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report