• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
No-Polarity Interruption Technology of Circuit Breakers for High
No-Polarity Interruption Technology of Circuit Breakers for High

Lecture notes-in-progress for the "Electromechanical grid"
Lecture notes-in-progress for the "Electromechanical grid"

... the frequency of the sinusoidal current and lf t is the series inductance of the line. We will neglect the shunt charging elements jB/2 in the π model. r and x can be combined to form a complex√impedance zf t = rf t + jxf t , in which (by electrical engineering notational tradition) j = −1. The inve ...
Chapter 1. Introduction to Solid State Physics.
Chapter 1. Introduction to Solid State Physics.

TN/TS-1500 Inverter Instruction Manual
TN/TS-1500 Inverter Instruction Manual

MAX1820/MAX1821 WCDMA Cellular Phone 600mA Buck Regulators General Description
MAX1820/MAX1821 WCDMA Cellular Phone 600mA Buck Regulators General Description

... that uses external feedback resistors to set the output voltage from 1.25V to V BATT , and the MAX1820 is specifically intended to power a linear PA in WCDMA handsets. An analog control signal dynamically adjusts the MAX1820’s output voltage from 0.4V to 3.4V with a settling time <30µs. The MAX1820/ ...
EE05 MITS sadhna 1
EE05 MITS sadhna 1

... inverter. Circuit configuration and theoretical operation also discussed in this paper. The performance of the topology is investigated through MATLAB-R2009a based simulation results. Keywords-Multilevel inverter, PWM Techniques, Total Harmonic Distortion. ...
AN-793 APPLICATION NOTE
AN-793 APPLICATION NOTE

... Simply put, a component is a single integrated device with interconnects while a system is a nonintegrated device built from several interconnected components. In almost all cases the distinction between a component and a system is obvious. However, the differences between component and system tests ...
Analyzing the forces within transtibial prosthetic sockets and design
Analyzing the forces within transtibial prosthetic sockets and design

... • Conduct trials with additional patients ▫ Test on multiple surfaces (incline, flat, stairs) • Analyze results, determine regions containing peak forces • Test several different types of sockets with Cody • Design and develop new socket: provide more cushioning in areas of greatest force • Determin ...
NC2322022204
NC2322022204

... current output of a power supply which has been derived from an alternating current source. The ripple is due to incomplete suppression of the alternating current waveform within the power supply. As the ripple causes reduction in resolution of the measuring instruments, it should be reduced up to p ...
Current Handling and Thermal Considerations in a High Current
Current Handling and Thermal Considerations in a High Current

Waveforms and definitions class notes
Waveforms and definitions class notes

Technical Teaching Equipment
Technical Teaching Equipment

... ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup a ...
達松發可動線圈 (D`Arsonval movement)
達松發可動線圈 (D`Arsonval movement)

... used. Figure 1-23 shows an ammeter that is designed to use external shunts and a d’Arsonval meter movement. Figure 1-23(A) shows the internal construction of the meter and the way in which the external shunt is connected to the meter and to the circuit being measured. Figure 1-23(C) shows some typic ...
Ω MAX9153/MAX9154 Low-Jitter, 800Mbps, 10-Port LVDS Repeaters with 100
Ω MAX9153/MAX9154 Low-Jitter, 800Mbps, 10-Port LVDS Repeaters with 100

... Low-Jitter, 800Mbps, 10-Port LVDS Repeaters with 100Ω Drive The MAX9153/MAX9154 low-jitter, low-voltage differential signaling (LVDS) repeaters are ideal for applications that require high-speed data or clock distribution while minimizing power, space, and noise. The devices accept a single LVDS inp ...
Alternating Current Motors
Alternating Current Motors

Operational Amplifier Circuits Comparators and Positive Feedback
Operational Amplifier Circuits Comparators and Positive Feedback

... Note that as Vin exceeds Vref, the voltage at the output of the comparator switches from VL to VH and the alarm is turned on. Notice that sometime after t1 the voltage Vin begins to decrease and at time t2 is crosses Vref . Now the output of the comparator switches back to VL and the alarm is turned ...
Insulation fault locator EDS460-DG
Insulation fault locator EDS460-DG

... transformers can be connected to one EDS460-DG. If more than 12 branch circuits are to be monitored, up to 90 EDS insulation fault locators can be connected via an RS-485 interface (BMS protocol), thereby 1080 branch circuits can be monitored. The maximum scanning time is approx. 4…10 s, see TGH1429 ...
ivo_AIDAprop_HV_SiPM_2
ivo_AIDAprop_HV_SiPM_2

... perhaps provide one of the FZU drivers (QMB1A). We discussed the gain vs temperature as measured by T3B: http://twiki.mppmu.mpg.de/bin/view/T3B/GainTemperatureDependence ...
exp04_add
exp04_add

4.5V to 18V Input Voltage, 3A/2A/2A Output Current Triple
4.5V to 18V Input Voltage, 3A/2A/2A Output Current Triple

... The TPS65261, TPS65261-1 features an automatic power sequence with connecting MODE pin to V7V and configuring EN1/2/3 pins. The device also features an open drain RESET signal to monitor power down. At light load, the TPS65261 automatically operates in pulse skipping mode (PSM) and the TPS65261-1 op ...
Datasheet - Intersil
Datasheet - Intersil

... The ISL24011 requires that VON2 be greater than or equal to VON1 at all times. Therefore, if VON1 and VON2 are different supplies, then VON2 needs to be turned on before VON1. The reason for this requirement is shown in Circuit 4 in the Pin Description Table. The ESD protection diode between VON2 an ...
Datasheet - Diodes Incorporated
Datasheet - Diodes Incorporated

... The selection of the inductor affects steady state operation as well as transient behavior and loop stability. These factors make it the most important component in power regulator design. There are three important inductor specifications, inductor value, DC resistance and saturation current. Consid ...
Interconnection Request and Generating Facility
Interconnection Request and Generating Facility

... allocations of Reliability Network Upgrades (RNUs) except short circuit related RNUs in the Cluster Phase I and Phase II interconnection studies. This is the value that will appear in the ISO Generation Interconnection Queue Report. Your TP Deliverability Allocations will not be able to exceed this ...
$doc.title

... Supply voltage, VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 V Supply voltage, VCC − . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
NESG2107M33 - California Eastern Laboratories
NESG2107M33 - California Eastern Laboratories

... Caution Observe precautions when handling because these devices are sensitive to electrostatic discharge. ...
< 1 ... 465 466 467 468 469 470 471 472 473 ... 1441 >

Current source



A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report