• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MEASURE OF ELECTRIC REACTIVE POWER 1. INTRODUCTION
MEASURE OF ELECTRIC REACTIVE POWER 1. INTRODUCTION

... as well as a formal relationship between active power, reactive power and apparent power, i.e. a power triangle, have been defined in order to investigate electric power phenomena. The power triangle is unquestionable if the object is linear and the voltage is sinusoidal. If the voltage is not sinus ...


... The X-600M is a multifunction web-enabled industrial I/O controller. It performs control, logic, and monitoring functions similar to that of a Programmable Logic Controller (PLC). However, unlike a PLC, the X-600M is designed for web-based applications from the ground up. No add-on software or hardw ...
Final Powerpoint project <- - 851KB
Final Powerpoint project <- - 851KB

Direct-AC, Linear LED Driver Topology: CCR Straight
Direct-AC, Linear LED Driver Topology: CCR Straight

... makes many factors mathematically predictable, lending incredible insight into the design process. For the figures below, LED load voltage has been normalized to the peak line voltage, so as to provide the most generalized analysis. As seen in Figures 8 and 9 below, input power, efficiency, and ther ...
Precision DC-to-AC power conversion by optimization
Precision DC-to-AC power conversion by optimization

Questionnaire for Installers on Transformers constraints and limitations
Questionnaire for Installers on Transformers constraints and limitations

DC – DC CONVERTER 1000W 100 - 400VDC Input / 12VDC Output
DC – DC CONVERTER 1000W 100 - 400VDC Input / 12VDC Output

... *2: the converter could sink an over-current from ~75A to ~80A for 60 sec (in these cases the signal output blinks) or an over-current peak > 80A for 200msec, over these time conditions it turns itself off for 5 sec. Than it tries to restart for the second time. If the overcharge persists, it turns ...
Herbert Stemmler
Herbert Stemmler

... Despite their successful use in traction vehicles, voltage source inverters (DC VSIs) still suffer from many restrictions which limit their application areas. Because of the high switching losses of the GTOs and especially of the snubber circuits, the basic three-phase two-level DC VSI (Figure 7-21 ...
PDF
PDF

... connected to induction motor has been performed and the generated signals THD is analysed. The system is supplied by a PV panel and batteries bank. That gives energy autonomy to the system. Simulation results give a better quality of stator current in terms of low harmonics, thus reducing the advers ...
A Static Power Model for Architects
A Static Power Model for Architects

... circuit that causes it to dissipate very low leakage power. The search problem for the vector that gives the least leakage power is a very difficult one because of the potentially huge size of the search space. Furthermore, it is not absolutely ...
February 25, 2008
February 25, 2008

... 2. The costs for the use of the distribution system typically recovered through conventional kWh charges are not recouped with the participation of microgrids. Is this an issue that could be partially addressed through national or state driven standards in support of policies enacted at wither the n ...
EMC filters 2-line filters SIFI-F for normal insertion loss
EMC filters 2-line filters SIFI-F for normal insertion loss

... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
No Prescription Required. Over The Counter Viagra Alternatives Uk
No Prescription Required. Over The Counter Viagra Alternatives Uk

Single-Inductor Dual-Output Buck-Boost Power Factor
Single-Inductor Dual-Output Buck-Boost Power Factor

1.2 MHz Step-up Converter for Display Bias
1.2 MHz Step-up Converter for Display Bias

... Display dimming can be achieved by controlling the output voltage, VOUT , using the FB pin. The circuitry behind the FB pin is flexible, to accommodate a variety of schemes used for dimming: • Adjust the duty cycle of the pulse train applied to the FB pin through resistor R3, as shown in figure 11. ...


"Super" Junction Transistors with Current Gains of 88 and Ultra-fast
"Super" Junction Transistors with Current Gains of 88 and Ultra-fast

... SJTs are capable of 250 °C operation, offer < 20 ns turn-on and turn-off capability, current gains as high as 88, low on-state voltage drop and high-current operation, due to the absence of a channel region and near zero Drain-Source offset voltage. Incorporating high voltage, high frequency and hig ...
Type of Electric Motors
Type of Electric Motors

... • Large safety factor when selecting motor • Under-utilization of equipment • Maintain outputs at desired level even at low input voltages • High starting torque is required ...
Integrated LC filter on silicon for DC-DC converter - HAL-LAAS
Integrated LC filter on silicon for DC-DC converter - HAL-LAAS

... power management of systems. In embedded systems, switched-mode DC-DC converters can be used for supplying devices which do not require an extremely low noise supply voltage but are the most power consuming (e.g. memory chips, base-band cores, power amplifiers). Typical application ranges are input ...
Single-stage, single-switch input-current
Single-stage, single-switch input-current

section 16920-1 - OPS Schneider Electric
section 16920-1 - OPS Schneider Electric

Elsevier Editorial System(tm) for Integration, the VLSI Journal
Elsevier Editorial System(tm) for Integration, the VLSI Journal

How to Prevent Power Surges:  Moxa White Paper
How to Prevent Power Surges: Moxa White Paper

... avalanche. In complex systems, even seemingly small events can have serious consequences. This is definitely true of industrial automation systems, in which many different devices need to work together in order to maintain normal operations. Computers and communications equipment are essential compo ...
MAX9111/MAX9113 Single/Dual LVDS Line Receivers with Ultra-Low Pulse Skew in SOT23 General Description
MAX9111/MAX9113 Single/Dual LVDS Line Receivers with Ultra-Low Pulse Skew in SOT23 General Description

... these pins against ESD of ±11kV without damage. The ESD structures withstand high ESD in all states: normal operation, shutdown, and powered down. ESD protection can be tested in various ways; the receiver inputs of this product family are characterized for protection to the limit of ±11kV using the ...
SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS® (PSS/E)  LAB3
SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS® (PSS/E) LAB3

... power flow analysis is at the heart of contingency analysis and the implementation of real-time monitoring systems. The creation of contingency (*.com), monitor and subsystem files will allow us to perform PF analysis. Important definition for better comprehension to this lab: ...
< 1 ... 337 338 339 340 341 342 343 344 345 ... 717 >

Distribution management system

In the recent years, utilization of electrical energy increased exponentially and customer requirement and quality definitions of power were changed enormously. As the electric energy became an essential part of the daily life, its optimal usage and reliability became important. Real-time network view and dynamic decisions have become instrumental for optimizing resources and managing demands, thus making a distribution management system which could handle proper work flows, very critical.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report