WECC Type 3 Wind Turbine Generator Model Specification
... 1. The generator/converter model (regc_a), which has inputs of real (Ipcmd) and reactive (Iqcmd) current command and outputs of real (Ip) and reactive (Iq) current injection into the grid model. This is identical to that proposed for the type 4 WTG, see [3]. 2. The electrical controls model (reec_a) ...
... 1. The generator/converter model (regc_a), which has inputs of real (Ipcmd) and reactive (Iqcmd) current command and outputs of real (Ip) and reactive (Iq) current injection into the grid model. This is identical to that proposed for the type 4 WTG, see [3]. 2. The electrical controls model (reec_a) ...
infratek 108a single- to six phase power analyzer
... Standard Measure Mode In the Standard Measure Mode 280 quantities per phase are measured without gap and are continuously updated. Values can be displayed on four display pages, can be saved in internal memory, or can be transferred via Interface to a computer. The display shows voltage, current, an ...
... Standard Measure Mode In the Standard Measure Mode 280 quantities per phase are measured without gap and are continuously updated. Values can be displayed on four display pages, can be saved in internal memory, or can be transferred via Interface to a computer. The display shows voltage, current, an ...
$doc.title
... specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters which may be provided in Motorola data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating ...
... specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters which may be provided in Motorola data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating ...
AN-695 APPLICATION NOTE
... VTEC is the voltage across the TEC. VLFB is the voltage measured at the LFB pin. VSFB is the voltage measured at the SFB pin. VVTEC is the voltage measured at the VTEC pin. VREF is the reference voltage. When taken from the ADN8831, VREF = 2.5 V. Alternatively, measuring the voltage difference betwe ...
... VTEC is the voltage across the TEC. VLFB is the voltage measured at the LFB pin. VSFB is the voltage measured at the SFB pin. VVTEC is the voltage measured at the VTEC pin. VREF is the reference voltage. When taken from the ADN8831, VREF = 2.5 V. Alternatively, measuring the voltage difference betwe ...
Evaluates: MAX17007A MAX17007A Evaluation Kit General Description Features
... for pulse-skipping control input. This four-level input determines the mode of operation under normal steadystate conditions and dynamic output-voltage transitions. The default configuration has a shunt installed across pins 1-3 for low-noise, forced-PWM mode. Table 6 lists the other selectable jump ...
... for pulse-skipping control input. This four-level input determines the mode of operation under normal steadystate conditions and dynamic output-voltage transitions. The default configuration has a shunt installed across pins 1-3 for low-noise, forced-PWM mode. Table 6 lists the other selectable jump ...
CET 3350 Scott Blvd., Bldg. 55. Unit 1
... Panelboard 5 from the current 12-pole positions to a minimum of 20-pole positions as well as increasing the 460Vac feeder and associated transformer. The actual operating current draw for each oven type needs to be verified to determine the capacity required to support the ovens. I would recommend o ...
... Panelboard 5 from the current 12-pole positions to a minimum of 20-pole positions as well as increasing the 460Vac feeder and associated transformer. The actual operating current draw for each oven type needs to be verified to determine the capacity required to support the ovens. I would recommend o ...
dynamics and 8tability of wind amd diesel
... energy storage can effectively damp electromechanical oscillations in a power system, because it provides storage capacity in addition to kinetic energy of the generator rotor,which can share the sudden changes in power requirement. Methods are described for the suitable control of the system and op ...
... energy storage can effectively damp electromechanical oscillations in a power system, because it provides storage capacity in addition to kinetic energy of the generator rotor,which can share the sudden changes in power requirement. Methods are described for the suitable control of the system and op ...
Evaluation Board EVAL-1EDI60I12AF
... inductance of the short circuit loop, the current may rise to rather high values which should be considered when using the test board in connection with sensitive loads, respectively other external circuits. ...
... inductance of the short circuit loop, the current may rise to rather high values which should be considered when using the test board in connection with sensitive loads, respectively other external circuits. ...
NE556
... No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, ...
... No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, ...
50mA-20A, Single-Supply, Low-Side or High
... Common mode rejection ratio describes an amplifiers ability to reject signals that are common to both inputs. Common mode rejection is therefore an important amplifier parameter when attempting to measure small differential voltages in the presence of large common mode voltages. The voltage develope ...
... Common mode rejection ratio describes an amplifiers ability to reject signals that are common to both inputs. Common mode rejection is therefore an important amplifier parameter when attempting to measure small differential voltages in the presence of large common mode voltages. The voltage develope ...
Document
... energy source to that of a higher-voltage DC before connecting it to a DC-AC inverter for grid-connected applications. Solar photovoltaics (PVs) and fuel cells (FCs) are low-voltage DC energy sources used in power conditioning systems (PCSs). To interlink PVs or FCs to 230-Vac single-phase or 3 x 40 ...
... energy source to that of a higher-voltage DC before connecting it to a DC-AC inverter for grid-connected applications. Solar photovoltaics (PVs) and fuel cells (FCs) are low-voltage DC energy sources used in power conditioning systems (PCSs). To interlink PVs or FCs to 230-Vac single-phase or 3 x 40 ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.11, pp. 1613-1618
... balanced by keeping the upper and lower dc link capacitor voltages balanced for proper operation of Neutral Point Clamped multilevel inverters. In most respects, the balancing of neutral point voltage is dishonor at very low operating frequencies of the inverter. The earlier proposed methods of neut ...
... balanced by keeping the upper and lower dc link capacitor voltages balanced for proper operation of Neutral Point Clamped multilevel inverters. In most respects, the balancing of neutral point voltage is dishonor at very low operating frequencies of the inverter. The earlier proposed methods of neut ...
PDF
... in multilevel power conversion technology was triggered by the work of Nabae, etal,who introduced the neutral-point clamped (NPC) inverter topology. It was immediately recognized that this new converter had many advantages over the more conventionaltwo-level inverter. Later, in the early nineties th ...
... in multilevel power conversion technology was triggered by the work of Nabae, etal,who introduced the neutral-point clamped (NPC) inverter topology. It was immediately recognized that this new converter had many advantages over the more conventionaltwo-level inverter. Later, in the early nineties th ...
LVPECL terminations - A circuit approach
... mode feedback from VCCO to the VTT node is 66% (actually somewhat less due to the different operating points of the output transistors), this is 60% higher than that of the standard termination feed forward path. While this difference between the two terminations may not seem significant at first, i ...
... mode feedback from VCCO to the VTT node is 66% (actually somewhat less due to the different operating points of the output transistors), this is 60% higher than that of the standard termination feed forward path. While this difference between the two terminations may not seem significant at first, i ...
Fulltext
... frequency 0, and the load Q-value Q. Also in this case the voltage gain is gmR (in the center of the passband R=0LQ), so eqs. (8) to (11) are still valid. The problem is that the availability of inductance properties is limited, which limits our choice of load capacitance and resistance. Typical o ...
... frequency 0, and the load Q-value Q. Also in this case the voltage gain is gmR (in the center of the passband R=0LQ), so eqs. (8) to (11) are still valid. The problem is that the availability of inductance properties is limited, which limits our choice of load capacitance and resistance. Typical o ...
wrong cable size? how did you determine the maximum demand?
... demand is at its peak. Although this method is also subject to interpretation, in my opinion when properly applied, it is the best way to determine maximum demand. Unfortunately, it does have a major drawback. The installation has to be complete and energised before it can be applied. This method re ...
... demand is at its peak. Although this method is also subject to interpretation, in my opinion when properly applied, it is the best way to determine maximum demand. Unfortunately, it does have a major drawback. The installation has to be complete and energised before it can be applied. This method re ...
mic+600/IU/TC
... In the add-on-menu of TouchControl, the user can, however, also pre-set the sensor to current or voltage output. In this menu, the measuring value output on the LED display with analogue sensors can additionally be changed to percentage indication. The window limits of the analogue characteristic ...
... In the add-on-menu of TouchControl, the user can, however, also pre-set the sensor to current or voltage output. In this menu, the measuring value output on the LED display with analogue sensors can additionally be changed to percentage indication. The window limits of the analogue characteristic ...
Traction drive control
... compact drive unit embedded into a single housing – high integration level, simple and fast integration to vehicle, applicable for both wheel and wheelset/axle drive, significantly reduced dimensions/volume and weight, ...
... compact drive unit embedded into a single housing – high integration level, simple and fast integration to vehicle, applicable for both wheel and wheelset/axle drive, significantly reduced dimensions/volume and weight, ...