µ OPA349 OPA2349 1
... Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these, or any other conditions beyond those specified, is not implied. (2) Input terminals are diode-clamped to the power-supply rails ...
... Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these, or any other conditions beyond those specified, is not implied. (2) Input terminals are diode-clamped to the power-supply rails ...
Lab 5 Document (Word)
... called state variables. The inputs to the system are the armature voltage, ea(t) and the motor load torque, TL. Equation 7a describes the electrical dynamics of the motor and equation 7b the mechanical dynamics. Solving these equations using appropriate computer routines will give plots of the respo ...
... called state variables. The inputs to the system are the armature voltage, ea(t) and the motor load torque, TL. Equation 7a describes the electrical dynamics of the motor and equation 7b the mechanical dynamics. Solving these equations using appropriate computer routines will give plots of the respo ...
A Power-Efficient Neural Tissue Stimulator With Energy Recovery , Member, IEEE
... done [5], results in 339 W or more of the total power consumption per current-source/electrode pair during stimulation. Since our design incorporates the power converter circuitry, we assume that a 0.25-V Schottky diode is used to generate the power supply, raising the consumed power to 373 W per el ...
... done [5], results in 339 W or more of the total power consumption per current-source/electrode pair during stimulation. Since our design incorporates the power converter circuitry, we assume that a 0.25-V Schottky diode is used to generate the power supply, raising the consumed power to 373 W per el ...
Dynamic Maximum Power Point Tracking of
... — has a well developed theoretical basis [19]. These features taken together make RCC distinct from prior methods. Many factors must be considered when designing a photovoltaic converter, so that no single method can be claimed to be the best. Due to the inherent low cost of implementation, RCC woul ...
... — has a well developed theoretical basis [19]. These features taken together make RCC distinct from prior methods. Many factors must be considered when designing a photovoltaic converter, so that no single method can be claimed to be the best. Due to the inherent low cost of implementation, RCC woul ...
Lab Manual - Lakehead University
... It is mandatory to perform all lab exercises according to course requirements. Failure to perform one or more lab exercises results in a grade of "F" for the course. When a student misses a lab exercise for whatever reason he/she must notify the instructor as soon as possible. If the reasons given f ...
... It is mandatory to perform all lab exercises according to course requirements. Failure to perform one or more lab exercises results in a grade of "F" for the course. When a student misses a lab exercise for whatever reason he/she must notify the instructor as soon as possible. If the reasons given f ...
Practical Considerations in Current Mode Power
... independent of load current or input voltage variations, at the lowest possible cost. In addition, end users allocate a minimal amount of system real estate in which it must fit. The major task facing design engineers is to overcome these constraints while exceeding the customers’ expectations, atta ...
... independent of load current or input voltage variations, at the lowest possible cost. In addition, end users allocate a minimal amount of system real estate in which it must fit. The major task facing design engineers is to overcome these constraints while exceeding the customers’ expectations, atta ...
FL7930B Single-Stage Flyback and Boundary-Mode PFC Controller for Lighting
... the amplifier. To cancel down the line input voltage effect on power factor correction, the effective control response of the PFC block should be slower than the line frequency and this conflicts with the transient response of the controller. Two-pole one-zero type compensation can meet both require ...
... the amplifier. To cancel down the line input voltage effect on power factor correction, the effective control response of the PFC block should be slower than the line frequency and this conflicts with the transient response of the controller. Two-pole one-zero type compensation can meet both require ...
MAX4289 1.0V Micropower, SOT23, Operational Amplifier General Description Features
... Driving Capacitive Loads The MAX4289 is unity-gain stable for loads up to 200pF. Applications that require greater capacitivedrive capability should use an isolation resistor between the output and the capacitive load (Figure 4). Note that this solution results in a loss of gain accuracy because RIS ...
... Driving Capacitive Loads The MAX4289 is unity-gain stable for loads up to 200pF. Applications that require greater capacitivedrive capability should use an isolation resistor between the output and the capacitive load (Figure 4). Note that this solution results in a loss of gain accuracy because RIS ...
MAX619 Regulated 5V Charge-Pump DC
... be used, but larger capacitors will increase output ripple. Ceramic or tantalum capacitors are recommended. ...
... be used, but larger capacitors will increase output ripple. Ceramic or tantalum capacitors are recommended. ...
300-mA, Sub-Bandgap Output Voltage, Low-Iq, Low
... However, the TLV712xx is designed to be stable with an effective capacitance of 0.1 mF or larger at the output. Thus, the device is stable with capacitors of other dielectric types as well, as long as the effective capacitance under operating bias voltage and temperature is greater than 0.1 mF. This ...
... However, the TLV712xx is designed to be stable with an effective capacitance of 0.1 mF or larger at the output. Thus, the device is stable with capacitors of other dielectric types as well, as long as the effective capacitance under operating bias voltage and temperature is greater than 0.1 mF. This ...
High-Voltage, High-Current OPERATIONAL AMPLIFIER DESCRIPTION FEATURES
... The OPA548 is a low-cost, high-voltage/high-current operational amplifier ideal for driving a wide variety of loads. A laser-trimmed monolithic integrated circuit provides excellent low-level signal accuracy and high output voltage and current. The OPA548 operates from either single or dual supplies ...
... The OPA548 is a low-cost, high-voltage/high-current operational amplifier ideal for driving a wide variety of loads. A laser-trimmed monolithic integrated circuit provides excellent low-level signal accuracy and high output voltage and current. The OPA548 operates from either single or dual supplies ...
BD1484EFJ
... ・The thermal Pad on the back side of IC has the great thermal conduction to the chip. So using the GND plain as broad and wide as possible can help thermal dissipation. And a lot of thermal via for helping the spread of heat to the different layer is also effective. ・The input capacitors should be c ...
... ・The thermal Pad on the back side of IC has the great thermal conduction to the chip. So using the GND plain as broad and wide as possible can help thermal dissipation. And a lot of thermal via for helping the spread of heat to the different layer is also effective. ・The input capacitors should be c ...
A Fast, Analytical Estimator for the SEU
... Electrical simulations are performed to obtain the pulse width of a voltage glitch for given R and C values of a gate Pulse width for other R and C values are obtained using linear relationship between the obtained pulse width and the new R and C values Cannot be used for different values of Q ...
... Electrical simulations are performed to obtain the pulse width of a voltage glitch for given R and C values of a gate Pulse width for other R and C values are obtained using linear relationship between the obtained pulse width and the new R and C values Cannot be used for different values of Q ...
testing harmonic limits in
... waveform and the required harmonic number. The output of the block FOURIER equals the amplitude of the required harmonic. For example, the following model calculates the 3th and 5th odd harmonic of the waveform Vi: ...
... waveform and the required harmonic number. The output of the block FOURIER equals the amplitude of the required harmonic. For example, the following model calculates the 3th and 5th odd harmonic of the waveform Vi: ...
www.maretron.com 1-866-550-9100
... and they are waterproof for continued operation even while submerged in the bilge. ...
... and they are waterproof for continued operation even while submerged in the bilge. ...
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
... rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 amperes for the 5 ...
... rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 amperes for the 5 ...
ADM1070 数据手册DataSheet 下载
... The ADM1070 is a negative voltage hot swap controller that allows a board to be safely inserted and removed from a live –48 V backplane. The part achieves this by providing robust current limiting, protection against transient and nontransient short circuits and overvoltage and undervoltage conditio ...
... The ADM1070 is a negative voltage hot swap controller that allows a board to be safely inserted and removed from a live –48 V backplane. The part achieves this by providing robust current limiting, protection against transient and nontransient short circuits and overvoltage and undervoltage conditio ...
MAX17558 60V, Dual-Output, Synchronous Step-Down
... controller that drives nMOSFETs. The device uses a constant-frequency, peak-current-mode architecture. The two outputs can be configured as independent voltage rails. Input capacitor size can be minimized by running the two outputs 180º out-of-phase. The IC supports current sensing using either an e ...
... controller that drives nMOSFETs. The device uses a constant-frequency, peak-current-mode architecture. The two outputs can be configured as independent voltage rails. Input capacitor size can be minimized by running the two outputs 180º out-of-phase. The IC supports current sensing using either an e ...
ESD Testing of MOS Gated Power Transistors
... knee at the point of failure. This knee is similar to that of a p-n junction, except symmetrical in voltage, with a similar tendency to "walk out." If this leakage was contained within 100 microA or so, the gate would not be damaged. To verify this, 11 devices where "gate avalanched" and then tested ...
... knee at the point of failure. This knee is similar to that of a p-n junction, except symmetrical in voltage, with a similar tendency to "walk out." If this leakage was contained within 100 microA or so, the gate would not be damaged. To verify this, 11 devices where "gate avalanched" and then tested ...
US_Renersolar2200~5000_English_User`s
... ※The Guidelines for Matching PV Array to the Renersolar PV-Inverter Input for determining the number of panels required in the PV string (panels connected in series), you must ensure that the following three requirements are met: 1. To avoid damage to the inverter, make sure the maximum open circuit ...
... ※The Guidelines for Matching PV Array to the Renersolar PV-Inverter Input for determining the number of panels required in the PV string (panels connected in series), you must ensure that the following three requirements are met: 1. To avoid damage to the inverter, make sure the maximum open circuit ...
ELI-S-250 Spec Sheet
... The ELI-S-250 is warranted for five (5) years from the date of purchase. This warranty excludes the batteries, which have a warranty of three (3) years with an additional seven (7) year pro-rated warranty. This warranty covers only properly installed Philips Bodine ELI-S-250 emergency units used und ...
... The ELI-S-250 is warranted for five (5) years from the date of purchase. This warranty excludes the batteries, which have a warranty of three (3) years with an additional seven (7) year pro-rated warranty. This warranty covers only properly installed Philips Bodine ELI-S-250 emergency units used und ...
N-channel 600 V, 0.86 typ., 5 A MDmesh II Plus™ low Qg Power
... Single pulse avalanche energy (starting Tj=25°C, ID= IAR; ...
... Single pulse avalanche energy (starting Tj=25°C, ID= IAR; ...
Power Factor Correction - MKK415-D-25-02MKK440-D-28.1
... statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check ...
... statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check ...