IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... bidirectional converters are getting more importance for past decades. Bidirectional converters can be isolated and nonisolated. Both of them have its own advantages and disadvantages. In applications where high power is required , bridge-type bidirectional converters are become an important [5-7] . ...
... bidirectional converters are getting more importance for past decades. Bidirectional converters can be isolated and nonisolated. Both of them have its own advantages and disadvantages. In applications where high power is required , bridge-type bidirectional converters are become an important [5-7] . ...
Overview Applications
... be provided by way of the Ethernet interface using the Powerover-Ethernet (PoE) standard. This allows fast and efficient interconnection with the associated data network. To support PoE power management, the Model 45DC’s PoE interface reports to the power sourcing equipment (PSE) that it is a class ...
... be provided by way of the Ethernet interface using the Powerover-Ethernet (PoE) standard. This allows fast and efficient interconnection with the associated data network. To support PoE power management, the Model 45DC’s PoE interface reports to the power sourcing equipment (PSE) that it is a class ...
BA3121F
... extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specified, ...
... extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specified, ...
This is a report of my findings from experimenting with 2 different
... So, 0.65v drop measured vs 0.75v drop theoretical for ambient pressure -> 500 Psi. That’s a fair bit of difference for someone with limited experience with electronics and I don’t yet know the full explanation for the difference. I’m assuming the strain gauge factor is 2 which is typical for strain ...
... So, 0.65v drop measured vs 0.75v drop theoretical for ambient pressure -> 500 Psi. That’s a fair bit of difference for someone with limited experience with electronics and I don’t yet know the full explanation for the difference. I’m assuming the strain gauge factor is 2 which is typical for strain ...
V. C. Summer Nuclear Station, Units 2 and 3 COL Application
... The breaker-and-a-half configuration has multiple connections made between the buses. Each connection between the buses is made with three circuit breakers and two circuits (referred to as a bay). This arrangement allows for breaker maintenance without interruption of service. A fault on either bus ...
... The breaker-and-a-half configuration has multiple connections made between the buses. Each connection between the buses is made with three circuit breakers and two circuits (referred to as a bay). This arrangement allows for breaker maintenance without interruption of service. A fault on either bus ...
MAX2510 Low-Voltage IF Transceiver with Limiter/RSSI and Quadrature Modulator ________________General Description
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
13620.90... 99 DC Measuring Amplifier
... The buttons (8) and (9) for the selection of the measurement range only respond when they are briefly held down. With continuous pressure on the button (> 0.5 s) the measurement range changes consecutively and continuously. 3.4 Current measurement The instrument has an extremely low voltage drop of ...
... The buttons (8) and (9) for the selection of the measurement range only respond when they are briefly held down. With continuous pressure on the button (> 0.5 s) the measurement range changes consecutively and continuously. 3.4 Current measurement The instrument has an extremely low voltage drop of ...
TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA
... sinusoidal output waveform with less than 5% total harmonic distortion at full rated load. Dynamic brownout protection must maintain the desired voltage without continuously switching to batteries in low voltage situations up to -15%. The system shall maintain output regulation of less than + 5% und ...
... sinusoidal output waveform with less than 5% total harmonic distortion at full rated load. Dynamic brownout protection must maintain the desired voltage without continuously switching to batteries in low voltage situations up to -15%. The system shall maintain output regulation of less than + 5% und ...
RT7275/76 - Richtek Technology
... pulses can ramp the inductor current higher to meet load requirements with minimal delays. Traditional current mode or voltage mode control schemes typically must monitor the feedback voltage, current signals (also for current limit), and internal ramps and compensation signals, to determine when to ...
... pulses can ramp the inductor current higher to meet load requirements with minimal delays. Traditional current mode or voltage mode control schemes typically must monitor the feedback voltage, current signals (also for current limit), and internal ramps and compensation signals, to determine when to ...
MAX1488E ±15kV ESD-Protected, Quad, Low-Power RS-232 Line Driver _______________General Description
... board are not damaged in an ESD strike. Currents as high as 60A can instantaneously pass into the ground, so it is important to minimize the ground-lead return path to the power supply. A separate return path to the power supply is recommended. Trace widths should be greater than 40 mils. VCC and VE ...
... board are not damaged in an ESD strike. Currents as high as 60A can instantaneously pass into the ground, so it is important to minimize the ground-lead return path to the power supply. A separate return path to the power supply is recommended. Trace widths should be greater than 40 mils. VCC and VE ...
MAX1552 Complete Power IC for Low-Cost PDAs General Description
... when no power is present at IN. Leakage current is typically 3µA with 3.3V at SDIG. ...
... when no power is present at IN. Leakage current is typically 3µA with 3.3V at SDIG. ...
BD6968FVM
... supply lines. An external direction diode can be added. Power supply line Back electromotive force causes regenerated current to power supply line, therefore take a measure such as placing a capacitor between power supply and GND for routing regenerated current. And fully ensure that the capacitor c ...
... supply lines. An external direction diode can be added. Power supply line Back electromotive force causes regenerated current to power supply line, therefore take a measure such as placing a capacitor between power supply and GND for routing regenerated current. And fully ensure that the capacitor c ...
AN020: Paralleling High Speed GaN Transistors
... performance. To effectively parallel high speed GaN transistors the parasitic imbalance contributed by the PCB layout must be minimized. We will look at two different parallel layouts based on the optimal layout discussed in the previous section and assess their ability to provide parallel performan ...
... performance. To effectively parallel high speed GaN transistors the parasitic imbalance contributed by the PCB layout must be minimized. We will look at two different parallel layouts based on the optimal layout discussed in the previous section and assess their ability to provide parallel performan ...
Expected Problems and Possible Approaches - Fraunhofer
... N North Sea of Germany 18 offshore wind farms have been approved (state August 2009) [1]. Further 46 wind farms are currently in the status of approval procedure [2]. The „ISET-concept“ for the connection of approved and some planned wind farms is shown on fig. 1 [3]. 12 out of 21 approved wind farm ...
... N North Sea of Germany 18 offshore wind farms have been approved (state August 2009) [1]. Further 46 wind farms are currently in the status of approval procedure [2]. The „ISET-concept“ for the connection of approved and some planned wind farms is shown on fig. 1 [3]. 12 out of 21 approved wind farm ...
docx
... An IBIS syntax checking program shall test for non-monotonic data and provide a maximum of one warning per I-V table if non-monotonic data is found. For example: “Warning: Line 300, Pulldown I-V table for model DC040403 is non-monotonic! Most EDA tools will filter this data to remove the non-monoton ...
... An IBIS syntax checking program shall test for non-monotonic data and provide a maximum of one warning per I-V table if non-monotonic data is found. For example: “Warning: Line 300, Pulldown I-V table for model DC040403 is non-monotonic! Most EDA tools will filter this data to remove the non-monoton ...
induction-motor-notes
... In practice this is impossible. Motor has to supply mechanical losses and iron losses alongwith small copper losses. Let us see how it can be explained in case of synchronous motor. 1.2 Synchronous Motor on No Load (With Losses) We have seen that Ebph and Vph are magnitudewise same, which is adjust ...
... In practice this is impossible. Motor has to supply mechanical losses and iron losses alongwith small copper losses. Let us see how it can be explained in case of synchronous motor. 1.2 Synchronous Motor on No Load (With Losses) We have seen that Ebph and Vph are magnitudewise same, which is adjust ...
A 1.2- mu m CMOS current-controlled oscillator - Solid
... capacitor CT. Although the unavoidable stray capacitances Cpl and Cpr do not form part of the timing capacitance, they nevertheless have an effect on oscillator timing. In order to overcome this problem, Sneep and Verhoven [12] and Banu [IO] (in a MOS equivalent) replaced the single floating capacit ...
... capacitor CT. Although the unavoidable stray capacitances Cpl and Cpr do not form part of the timing capacitance, they nevertheless have an effect on oscillator timing. In order to overcome this problem, Sneep and Verhoven [12] and Banu [IO] (in a MOS equivalent) replaced the single floating capacit ...