LM1575/LM1575HV/LM2575/LM2575HV Series SIMPLE
... The LM2575 series of regulators are monolithic integrated circuits that provide all the active functions for a step-down (buck) switching regulator, capable of driving a 1A load with excellent line and load regulation. These devices are available in fixed output voltages of 3.3V, 5V, 12V, 15V, and a ...
... The LM2575 series of regulators are monolithic integrated circuits that provide all the active functions for a step-down (buck) switching regulator, capable of driving a 1A load with excellent line and load regulation. These devices are available in fixed output voltages of 3.3V, 5V, 12V, 15V, and a ...
Word
... Pump (ESP) Applications 100 – 1,000 kVA Note: Any item below labeled as {Optional} should be used or removed to ensure spec clarity. ...
... Pump (ESP) Applications 100 – 1,000 kVA Note: Any item below labeled as {Optional} should be used or removed to ensure spec clarity. ...
General Description Features
... turns-ratio transformer from HALO sets the output voltage range from 6.8V to 34.8V with a 300mA current limit. The EV kit provides greater than 90% overall efficiency at +24V between 2.2W and up to 8.3W output power using an H-bridge DC-DC converter topology. Input-ripple current and radiated noise ...
... turns-ratio transformer from HALO sets the output voltage range from 6.8V to 34.8V with a 300mA current limit. The EV kit provides greater than 90% overall efficiency at +24V between 2.2W and up to 8.3W output power using an H-bridge DC-DC converter topology. Input-ripple current and radiated noise ...
MOV General Electrical
... step function to the stray capacitance and inductance of the secondary winding can generate an oscillatory transient voltage with a peak amplitude up to twice the normal peak secondary voltage. De-Energizing the transformer primary • The opening of the primary circuit of a transformer generates extr ...
... step function to the stray capacitance and inductance of the secondary winding can generate an oscillatory transient voltage with a peak amplitude up to twice the normal peak secondary voltage. De-Energizing the transformer primary • The opening of the primary circuit of a transformer generates extr ...
P84396
... locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for example, may require special precautions to assure electrical noise immunity (e.g. audio crosstalk). NOTE: This equipment has been tested and found to comply with ...
... locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for example, may require special precautions to assure electrical noise immunity (e.g. audio crosstalk). NOTE: This equipment has been tested and found to comply with ...
WDT400 - Walchem
... recirculation pump, and returned to either the cooling tower sump or the suction side of the recirculation pump. ...
... recirculation pump, and returned to either the cooling tower sump or the suction side of the recirculation pump. ...
HMC199MS8 数据资料DataSheet下载
... general purpose dual SPDT GaAs “bypass” switches in 8-lead MSOP packages covering DC to 2.5 GHz. These four-RF- port components integrate two SPDT switches and a through line onto a single IC. The designs provide low insertion loss of less than 0.5 dB while switching passive or active external circu ...
... general purpose dual SPDT GaAs “bypass” switches in 8-lead MSOP packages covering DC to 2.5 GHz. These four-RF- port components integrate two SPDT switches and a through line onto a single IC. The designs provide low insertion loss of less than 0.5 dB while switching passive or active external circu ...
Electrical Engineering - SK Engineering Academy
... The process by which current in the short circuited coil is reversed while it crosses the magnetic neutral axis is called “commutation”. The brief period during which coil remains short circuited is known as commutation period. 35. What happens when a D.C. Shunt motor is directly connected to the s ...
... The process by which current in the short circuited coil is reversed while it crosses the magnetic neutral axis is called “commutation”. The brief period during which coil remains short circuited is known as commutation period. 35. What happens when a D.C. Shunt motor is directly connected to the s ...
VJ1000 - Klompenboer
... both for the personnel performing them and for the device itself, that shall be used only by trained personnel. R.V.R. doesn’t assume responsibility for injury or damage resulting from improper procedures or practices by untrained/unqualified personnel in the handling of this unit. Please observe al ...
... both for the personnel performing them and for the device itself, that shall be used only by trained personnel. R.V.R. doesn’t assume responsibility for injury or damage resulting from improper procedures or practices by untrained/unqualified personnel in the handling of this unit. Please observe al ...
Current Source Modular Multilevel Converter for HVDC and FACTS
... against internal open-circuit faults. A back-to-back presspack diode pair is connected in parallel with each switch element in an inductor cell. The diodes must have a lower breakdown voltage than the switch element. Such diodes can be standard rectification diodes, hence very low cost. They do not ...
... against internal open-circuit faults. A back-to-back presspack diode pair is connected in parallel with each switch element in an inductor cell. The diodes must have a lower breakdown voltage than the switch element. Such diodes can be standard rectification diodes, hence very low cost. They do not ...
MAX3205E/MAX3207E/MAX3208E Dual, Quad, and Hex High-Speed Differential ESD-Protection ICs General Description
... consists of a pair of diodes that steer ESD current pulses to VCC or GND. The MAX3205E/MAX3207E/MAX3208E protect against ESD pulses up to ±15kV Human Body Model, ±8kV Contact Discharge, and ±15kV Air-Gap Discharge, as specified in IEC 61000-4-2. An integrated TVS ensures that the voltage rise seen o ...
... consists of a pair of diodes that steer ESD current pulses to VCC or GND. The MAX3205E/MAX3207E/MAX3208E protect against ESD pulses up to ±15kV Human Body Model, ±8kV Contact Discharge, and ±15kV Air-Gap Discharge, as specified in IEC 61000-4-2. An integrated TVS ensures that the voltage rise seen o ...
R5011ANJ
... "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. ...
... "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. ...
ZLNB2015
... or below 7.5V. These logic outputs can be used to disable any LNB RF output connected to a receiver (STB) that has been powered down or disconnected (and hence not providing correct cable matching). The ZLNB2015 includes circuitry necessary to detect the presence of a 22kHz tone modulated on either ...
... or below 7.5V. These logic outputs can be used to disable any LNB RF output connected to a receiver (STB) that has been powered down or disconnected (and hence not providing correct cable matching). The ZLNB2015 includes circuitry necessary to detect the presence of a 22kHz tone modulated on either ...
26 13 16 Medium-voltage fusible interrupter switchgear (air
... insulators shall be such that a uniform voltage gradient is produced over the entire surface. The bushing-type insulators will support the live conductors and (where necessary) provide a gas tight barrier between the vessel and air. ...
... insulators shall be such that a uniform voltage gradient is produced over the entire surface. The bushing-type insulators will support the live conductors and (where necessary) provide a gas tight barrier between the vessel and air. ...
- Interroll
... When the speed of a rotating RollerDrive is abruptly reduced (e. g. by taking away or reducing the start signal at the DriveControl), the RollerDrive briefly rotates further (depending on the weight of the conveyed goods being stopped) and thus functions as a generator. The voltage generated in this ...
... When the speed of a rotating RollerDrive is abruptly reduced (e. g. by taking away or reducing the start signal at the DriveControl), the RollerDrive briefly rotates further (depending on the weight of the conveyed goods being stopped) and thus functions as a generator. The voltage generated in this ...