LTC2942 - Battery Gas Gauge with Temperature, Voltage
... I2C/SMBus Interface The LTC2942 communicates with a bus master using a 2-wire interface compatible with I2C and SMBus. The 7-bit hard-coded I2C address of the LTC2942 is 1100100. The LTC2942 is a slave-only device. Therefore the serial clock line (SCL) is an input only while the serial data line (SD ...
... I2C/SMBus Interface The LTC2942 communicates with a bus master using a 2-wire interface compatible with I2C and SMBus. The 7-bit hard-coded I2C address of the LTC2942 is 1100100. The LTC2942 is a slave-only device. Therefore the serial clock line (SCL) is an input only while the serial data line (SD ...
APT Manual Transfer Generator Quick Connection Switchboard
... your project. Also delete any other items or paragraphs that does not apply. of the lower door shall have an additional horizontal hinge to allow for the door to be closed while cables are connected. ...
... your project. Also delete any other items or paragraphs that does not apply. of the lower door shall have an additional horizontal hinge to allow for the door to be closed while cables are connected. ...
Week No - ITI Gorwa
... Principles of Electromagnetism corkscrew rule, right and left hand rules. Mg. Field of current carrying conductors and loop. Earth magnetism, solenoid its property. ...
... Principles of Electromagnetism corkscrew rule, right and left hand rules. Mg. Field of current carrying conductors and loop. Earth magnetism, solenoid its property. ...
c-14-deee-5th-sem
... Sending end P.F iii) percentage regulation iv) Efficiency for the given receiving end condition Solve problems on short lines Compute the percentage regulation, efficiency of medium transmission lines with given receiving end conditions and line parameters using i) Nominal ( pie ) method ii) Nominal ...
... Sending end P.F iii) percentage regulation iv) Efficiency for the given receiving end condition Solve problems on short lines Compute the percentage regulation, efficiency of medium transmission lines with given receiving end conditions and line parameters using i) Nominal ( pie ) method ii) Nominal ...
DuraNET 30-2020
... mining, industrial), the unit provides reliable local area network (LAN) switching capabilities with the ease of use, secure access, and manageability expected from Cisco-based technology. Two levels of Cisco IOS software (LAN Lite or LAN Base) are available to support access layer connectivity and ...
... mining, industrial), the unit provides reliable local area network (LAN) switching capabilities with the ease of use, secure access, and manageability expected from Cisco-based technology. Two levels of Cisco IOS software (LAN Lite or LAN Base) are available to support access layer connectivity and ...
SEL-451-Based Autosynchronizer Data Sheet
... Three-Close Conditions. Close the controlled circuit breaker under three conditions with specific close acceptance criteria: autosynchronize close (phase angle is slipping), parallel close (zero slip conditions), and live generator/dead-bus close. Autosynchronize Acceptance Criteria. Initiate an aut ...
... Three-Close Conditions. Close the controlled circuit breaker under three conditions with specific close acceptance criteria: autosynchronize close (phase angle is slipping), parallel close (zero slip conditions), and live generator/dead-bus close. Autosynchronize Acceptance Criteria. Initiate an aut ...
Fault Finding
... Proceed to your cut-out switches and switch off the first cut-out switch and take a reading. If the voltage is good, this first section of fence line is sound. Proceed to the next cut-out and repeat the procedure until the section of fence line that has the fault is located. Then locate the fault in ...
... Proceed to your cut-out switches and switch off the first cut-out switch and take a reading. If the voltage is good, this first section of fence line is sound. Proceed to the next cut-out and repeat the procedure until the section of fence line that has the fault is located. Then locate the fault in ...
maxon DC motor and maxon EC motor Key information
... able to dissipate and the maximum rotor temperature (line 22 of the motor data) should not be exceeded. This results in a maximum continuous current, at which the maximum winding temperature is attained under standard conditions (25°C ambient temperature, no heat dissipation via the flange, free air ...
... able to dissipate and the maximum rotor temperature (line 22 of the motor data) should not be exceeded. This results in a maximum continuous current, at which the maximum winding temperature is attained under standard conditions (25°C ambient temperature, no heat dissipation via the flange, free air ...
Stakeholder Comment and Rationale Form AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft
... which the exemptions apply. If only some of the exemptions are listed, market participants will not be able to rely on this subsection to determine applicability and may not refer back to this subsection when reviewing the specific requirements. Therefore, the individual subsections from which some ...
... which the exemptions apply. If only some of the exemptions are listed, market participants will not be able to rely on this subsection to determine applicability and may not refer back to this subsection when reviewing the specific requirements. Therefore, the individual subsections from which some ...
CD54ACT04, CD74ACT04 HEX INVERTERS D
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
BD9015KV-M
... COMP voltage will drop and recovery will be done with the minimum duty cycle, which may lead to undershoot of the output. In case this undershoot becomes an application problem, the output capacitor should be increased or the phase compensation RC constant should be adjusted. BD9016KV-M, If the outp ...
... COMP voltage will drop and recovery will be done with the minimum duty cycle, which may lead to undershoot of the output. In case this undershoot becomes an application problem, the output capacitor should be increased or the phase compensation RC constant should be adjusted. BD9016KV-M, If the outp ...
Performance Analysis of Double Inverter Fed Wound Rotor Induction
... variations such as the rotor time constant and an incorrect flux measurement or estimation at low speeds. Consequently, performance deteriorates and a conventional controller such as a PID is unable to maintain satisfactory performance under these conditions [7-9]. In this paper a composite control ...
... variations such as the rotor time constant and an incorrect flux measurement or estimation at low speeds. Consequently, performance deteriorates and a conventional controller such as a PID is unable to maintain satisfactory performance under these conditions [7-9]. In this paper a composite control ...
A Shoe-Embedded Piezoelectric Energy Harvester for Wearable
... Wearable sensors are becoming smaller and increasingly widely used, resulting in an increasing need for independent and compact power supplies. Electrochemical batteries, the most common power supplies for wearable sensors, cannot meet the need because of their limited energy storage capacity and po ...
... Wearable sensors are becoming smaller and increasingly widely used, resulting in an increasing need for independent and compact power supplies. Electrochemical batteries, the most common power supplies for wearable sensors, cannot meet the need because of their limited energy storage capacity and po ...
Parallel Operation and Standby Service Schedule Designation R3
... If the total of daily demand charges for the month is less than the monthly generation reservation fee, then the daily demand charges will be waived for that month. If the total of daily demand charges for the month is greater than the monthly generation reservation fee, then the generation reservat ...
... If the total of daily demand charges for the month is less than the monthly generation reservation fee, then the daily demand charges will be waived for that month. If the total of daily demand charges for the month is greater than the monthly generation reservation fee, then the generation reservat ...
LM2596 SIMPLE SWITCHER(RM) Power Converter 150 kHz 3A
... shown in Figure 3, locate the 5V output voltage section. In the load current column, choose the load current line that is closest to the current needed in your application, for this example, use the 3A line. In the maximum input voltage column, select the line that covers the input voltage needed in ...
... shown in Figure 3, locate the 5V output voltage section. In the load current column, choose the load current line that is closest to the current needed in your application, for this example, use the 3A line. In the maximum input voltage column, select the line that covers the input voltage needed in ...
MAX16948 Evaluation Kit Evaluates: MAX16948 General Description Features
... The EV kit provides D2 and D3 to monitor the fault indicator outputs, ERR1 and ERR2, respectively. The LED lights up when a fault is detected. ...
... The EV kit provides D2 and D3 to monitor the fault indicator outputs, ERR1 and ERR2, respectively. The LED lights up when a fault is detected. ...
AN170 NE555 and NE556 applications
... By utilizing one or any combination of basic operating modes and suitable variations, it is possible to utilize the timer in a myriad of applications. The applications are limited only to the imagination of the designer. One of the simplest and most widely used operating modes of the timer is the mo ...
... By utilizing one or any combination of basic operating modes and suitable variations, it is possible to utilize the timer in a myriad of applications. The applications are limited only to the imagination of the designer. One of the simplest and most widely used operating modes of the timer is the mo ...
Low-Power Single Operational Amplifier
... anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components ...
... anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components ...