pm700 installation manual
... Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions. NEVER work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all sources of electric power. Assume that al ...
... Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions. NEVER work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all sources of electric power. Assume that al ...
SIMATIC S7-200 SMART
... industrial automation. Committed to R&D, promotion and application of latest technologies, Siemens has been instrumental in enhancing our customers’ competitiveness for over 140 years. Our state-of-the art automation products and solutions not only improve production efficiency but also reduce total ...
... industrial automation. Committed to R&D, promotion and application of latest technologies, Siemens has been instrumental in enhancing our customers’ competitiveness for over 140 years. Our state-of-the art automation products and solutions not only improve production efficiency but also reduce total ...
Understanding the Physics of Electrodynamic Shaker Performance
... 1% damping. This provides another order of magnitude reduction in building forces. Figure 9 presents the low frequency end of the maximum table acceleration plot for these three configurations. Note that the slab mounted response essentially overlays the rigid mounting case, while the air-mount isol ...
... 1% damping. This provides another order of magnitude reduction in building forces. Figure 9 presents the low frequency end of the maximum table acceleration plot for these three configurations. Note that the slab mounted response essentially overlays the rigid mounting case, while the air-mount isol ...
Trame Rapport
... the mall opening - to secure the mall delivery - all this with a “just enough” solution (3 years ROI at the maximum for “above the minimum” features) The answers for electrical distribution are: - electrical distribution architecture oriented to increase continuity of supply especially for lighting, ...
... the mall opening - to secure the mall delivery - all this with a “just enough” solution (3 years ROI at the maximum for “above the minimum” features) The answers for electrical distribution are: - electrical distribution architecture oriented to increase continuity of supply especially for lighting, ...
ONET4291PA 数据资料 dataSheet 下载
... The ONET4291PA uses a two-wire serial interface for digital control of the amplifier bandwidth, output amplitude, and LOS threshold. A simplified block diagram of this interface is given in Figure 3. SDA and SCK are inputs for the serial data and the serial clock, respectively, and can be driven by ...
... The ONET4291PA uses a two-wire serial interface for digital control of the amplifier bandwidth, output amplitude, and LOS threshold. A simplified block diagram of this interface is given in Figure 3. SDA and SCK are inputs for the serial data and the serial clock, respectively, and can be driven by ...
Scintillation Breakdowns in Tantalum Capacitors
... VBR results in significant reduction of life test failures [6]. Uncertainty in the meaning of VR and its relation to VBR casts some doubt upon the results of reliability estimations. This also reduces the effectiveness of derating, which might be excessive in some cases and insufficient in others. O ...
... VBR results in significant reduction of life test failures [6]. Uncertainty in the meaning of VR and its relation to VBR casts some doubt upon the results of reliability estimations. This also reduces the effectiveness of derating, which might be excessive in some cases and insufficient in others. O ...
FFP08S60SN 8 A, 600 V STEALTH II Diode STEALTH™ II
... EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used here in: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance wit ...
... EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used here in: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance wit ...
AlarmSense Product Guide
... AlarmSense detectors and other devices depend for their operation on the ability of the control and indicating equipment to switch between several different operating voltages. Control and indicating equipment must, therefore, be designed for the specific purpose of powering and controlling AlarmSen ...
... AlarmSense detectors and other devices depend for their operation on the ability of the control and indicating equipment to switch between several different operating voltages. Control and indicating equipment must, therefore, be designed for the specific purpose of powering and controlling AlarmSen ...
Industrial IGBT Modules Explanation of Technical Information
... The difference between a preliminary and a final datasheet is, that certain values are still missing, for example the maximum values. These missing values in the preliminary datasheet are marked to be defined (t.b.d.). Modules without ENG on the label reached series production status. All quality re ...
... The difference between a preliminary and a final datasheet is, that certain values are still missing, for example the maximum values. These missing values in the preliminary datasheet are marked to be defined (t.b.d.). Modules without ENG on the label reached series production status. All quality re ...
Modeling of Pulse Transformers with Parallel- and Non
... the equations, what results in a relatively poor accuracy. The capacitance between the secondary and ground is mentioned in [1] but there is no equation given for calculating it. This could be seen in Figure 1 where a measured and two calculated pulse responses of a transformer are shown. The input ...
... the equations, what results in a relatively poor accuracy. The capacitance between the secondary and ground is mentioned in [1] but there is no equation given for calculating it. This could be seen in Figure 1 where a measured and two calculated pulse responses of a transformer are shown. The input ...
APPLICATION NOTE - TDA8768A/C2 - 12-BIT HIGH-SPEED A/D CONVERTER DEMONSTRATION BOARD
... and a 220nF AC coupling to the external generator by the IN SMA connector. This connector is adapted by a 50Ω microstrip line and is connected to a 100Ω resistor. This value is calculated to have 50Ω equivalent ending: A 100Ω resistor connected between the both ADC analog inputs ensures a 50Ω matchi ...
... and a 220nF AC coupling to the external generator by the IN SMA connector. This connector is adapted by a 50Ω microstrip line and is connected to a 100Ω resistor. This value is calculated to have 50Ω equivalent ending: A 100Ω resistor connected between the both ADC analog inputs ensures a 50Ω matchi ...
Protection from the harmful effects of arcing faults
... on circuit breaker doors helps to minimize equipment size for two-high configurations Ability to mount protective relays, meters and other controls on each of the three compartment doors allows for more compact switchgear designs ...
... on circuit breaker doors helps to minimize equipment size for two-high configurations Ability to mount protective relays, meters and other controls on each of the three compartment doors allows for more compact switchgear designs ...
Design tips for an efficient non-inverting buck-boost converter By Haifeng Fan Introduction
... anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components ...
... anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components ...
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
... switches fully rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 am ...
... switches fully rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 am ...
and Dual-Channel Antenna LDO With Current
... LIM, LIM1, LIM2, SENSE_EN , SENSE_SEL, ERR, FB, FB1, and FB2 (3) (4) ...
... LIM, LIM1, LIM2, SENSE_EN , SENSE_SEL, ERR, FB, FB1, and FB2 (3) (4) ...
LTM4620 - Dual 13A or Single 26A DC/DC µModule Regulator
... and Soft-Start Inputs. Each channel has a 1.3µA pull-up current source. When one channel is configured to be master of the two channels, then a capacitor from this pin to ground will set a soft-start ramp rate. The remaining channel can be set up as the slave, and have the master’s output applied th ...
... and Soft-Start Inputs. Each channel has a 1.3µA pull-up current source. When one channel is configured to be master of the two channels, then a capacitor from this pin to ground will set a soft-start ramp rate. The remaining channel can be set up as the slave, and have the master’s output applied th ...
MAX8709B High-Efficiency CCFL Backlight Controller with SMBus Interface General Description
... High-Efficiency CCFL Backlight Controller with SMBus Interface The MAX8709B integrated backlight controller is optimized to drive cold-cathode fluorescent lamps (CCFLs) using a resonant full-bridge inverter architecture. The resonant operation maximizes striking capability and provides near-sinusoid ...
... High-Efficiency CCFL Backlight Controller with SMBus Interface The MAX8709B integrated backlight controller is optimized to drive cold-cathode fluorescent lamps (CCFLs) using a resonant full-bridge inverter architecture. The resonant operation maximizes striking capability and provides near-sinusoid ...
LTC2920-1/LTC2920-2 - Single/Dual Power Supply Margining
... are powered from this pin. VCC should be connected to a low noise power supply voltage between 2.3V and 6V and should be bypassed with at least a 0.1μF capacitor to the GND pin in close proximity to the LTC2920. Current sourced out of the IM pins comes from the VCC pin. Note that VCC must come up no ...
... are powered from this pin. VCC should be connected to a low noise power supply voltage between 2.3V and 6V and should be bypassed with at least a 0.1μF capacitor to the GND pin in close proximity to the LTC2920. Current sourced out of the IM pins comes from the VCC pin. Note that VCC must come up no ...
BDTIC CoolSET -F3R80 I C E 3 A R 4 7 8 0...
... The features include BiCMOS technology to reduce power consumption and increase the Vcc voltage range, cycle by cycle current mode control, built-in 10ms soft start to reduce the stress of switching elements during start up, built-in 40ms for short period of peak power before entering protection, ac ...
... The features include BiCMOS technology to reduce power consumption and increase the Vcc voltage range, cycle by cycle current mode control, built-in 10ms soft start to reduce the stress of switching elements during start up, built-in 40ms for short period of peak power before entering protection, ac ...