INVESTIGATION OF HIGH-PERFORMANCE DC-DC CONVERTERS FOR PLUG-
... PHEVs, battery chargers for automotive applications are becoming a large market for the power supply industry. The most common charger power architecture includes an ac-dc converter with power factor correction (PFC) followed by an isolated dc-dc converter. As a key component of a charger system, th ...
... PHEVs, battery chargers for automotive applications are becoming a large market for the power supply industry. The most common charger power architecture includes an ac-dc converter with power factor correction (PFC) followed by an isolated dc-dc converter. As a key component of a charger system, th ...
AN00093 TJA1020 LIN transceiver Rev. 02 — 16 September 2005 Application note
... The TJA1020 is designed to support the increasing demand for lower supply voltages than 5 V within automotive applications. It provides reduced input thresholds at the input pins TXD and NSLP and open drains at the output pins RXD and TXD. So it is compatible to 3.0 V/3.3 V supplied microcontroller ...
... The TJA1020 is designed to support the increasing demand for lower supply voltages than 5 V within automotive applications. It provides reduced input thresholds at the input pins TXD and NSLP and open drains at the output pins RXD and TXD. So it is compatible to 3.0 V/3.3 V supplied microcontroller ...
MOTORTRONICS™
... includes overload protection in normal operation mode and will sequence the isolation contactor, so all logic control should be done at the MVC Plus control unit. Avoid turning the MVC Plus on and off using the isolation device. 120V control power must be supplied (minimum of 750VA) to the control b ...
... includes overload protection in normal operation mode and will sequence the isolation contactor, so all logic control should be done at the MVC Plus control unit. Avoid turning the MVC Plus on and off using the isolation device. 120V control power must be supplied (minimum of 750VA) to the control b ...
FX Inverter/Charger
... Welcome to OutBack Power Technologies ......................................................................................................................... 8 Inverter Functions ...................................................................................................................... ...
... Welcome to OutBack Power Technologies ......................................................................................................................... 8 Inverter Functions ...................................................................................................................... ...
DNV-OS-D201: Electrical Installations
... — Sec.1: Tables for documentation requirements have been included in Ch.3 Sec.1 and are updated and aligned the matrix approach in Rules for Ships Part 0 Chapter 3 and DNV-RP-A201. — Sec.1: Semiconductor converters may be certified in a “two stage” process: This implies that the switchboard part is ...
... — Sec.1: Tables for documentation requirements have been included in Ch.3 Sec.1 and are updated and aligned the matrix approach in Rules for Ships Part 0 Chapter 3 and DNV-RP-A201. — Sec.1: Semiconductor converters may be certified in a “two stage” process: This implies that the switchboard part is ...
The circuit breakers shall be subjected to routine and type
... authority is satisfied about the fulfilment of eligibility criteria by the firm. IDCO shall not be responsible for any delay/ difficulty/ inaccessibility of the downloading facility. In case of any discrepancy between the tender documents downloaded from Internet and the master copy available in the ...
... authority is satisfied about the fulfilment of eligibility criteria by the firm. IDCO shall not be responsible for any delay/ difficulty/ inaccessibility of the downloading facility. In case of any discrepancy between the tender documents downloaded from Internet and the master copy available in the ...
KT-400 Installation Manual DN2003.book
... This equipment, KT-400 Ethernet Four-Door Controller Model KT-400-EU, shall be used installed and used within an environment that provides the pollution degree max 2 and over voltages category II NON HAZARDOUS LOCATIONS, INDOOR only. The equipment is FIXED and PERMANENTLY CONNECTED and is designed t ...
... This equipment, KT-400 Ethernet Four-Door Controller Model KT-400-EU, shall be used installed and used within an environment that provides the pollution degree max 2 and over voltages category II NON HAZARDOUS LOCATIONS, INDOOR only. The equipment is FIXED and PERMANENTLY CONNECTED and is designed t ...
user`s manual - Fuji Electric Europe
... cannot emergency-stop the inverter using the STOP key on the built-in keypad. • If an alarm reset is made with the operation signal turned on, a sudden start will occur. Ensure that the operation signal is turned off in advance. Otherwise an accident could occur. • If you enable the "restart mode af ...
... cannot emergency-stop the inverter using the STOP key on the built-in keypad. • If an alarm reset is made with the operation signal turned on, a sudden start will occur. Ensure that the operation signal is turned off in advance. Otherwise an accident could occur. • If you enable the "restart mode af ...
technical specification for
... climatic conditions ozone, acid, alkalis, zinc or dust. The manufacturing shall be by the wet process and impervious character obtained by through vitrification. The insulator shall be made of highest grade, dense, homogeneous, wet-process porcelain, completely and uniformly vitrified throughout to ...
... climatic conditions ozone, acid, alkalis, zinc or dust. The manufacturing shall be by the wet process and impervious character obtained by through vitrification. The insulator shall be made of highest grade, dense, homogeneous, wet-process porcelain, completely and uniformly vitrified throughout to ...
Conduction Losses and Common Mode EMI Analysis on
... based on simulation results when only the conduction losses are taken into account. Totem-pole PFC in Fig. 6, Two-boostcircuit PFC in Fig. 4 and Pseudo Totem-pole in Fig. 5 has better efficiency comparing with other topologies. These are according with what has been discussed theoretically in part A ...
... based on simulation results when only the conduction losses are taken into account. Totem-pole PFC in Fig. 6, Two-boostcircuit PFC in Fig. 4 and Pseudo Totem-pole in Fig. 5 has better efficiency comparing with other topologies. These are according with what has been discussed theoretically in part A ...
Solenoid Basics - DSF Technologies
... reduces the solenoid’s available force. Increasing the distance between the solenoid and the lever-actuating mechanism will reduce the force lost due to side loading friction. ...
... reduces the solenoid’s available force. Increasing the distance between the solenoid and the lever-actuating mechanism will reduce the force lost due to side loading friction. ...