• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Hospital Isolated Power Systems
Hospital Isolated Power Systems

... Electric equipment operating in the patient vicinity, even though operating perfectly, may still be hazardous to the patient. This is because every piece of electrical equipment produces a leakage current. The leakage consists of any current, including capacitively coupled current, not intended to b ...
Installation Considerations for Multi
Installation Considerations for Multi

... current may also effect sensitive electronic equipment referenced to ground and is discussed in [2-5]. The solution to these problems was the addition of a special PWM output filter and an input high resistance ground isolation transformer for each drive discussed in Section V. III. ...
A High Accurate and High Output Impedance Current Mirror
A High Accurate and High Output Impedance Current Mirror

Third Rail Fuse Link Application Guide
Third Rail Fuse Link Application Guide

... It is usual that there are a number of shoes to each fuse link depending on the system. When there is a situation when the third rail will alternate sides of the train each side feeding separate fuse links then under normal operating conditions the RMS current through the fuse links will be reduced. ...
6. Internal lightning protection
6. Internal lightning protection

... system from conductive components of the building structure (metal structural parts, reinforcement etc.), and the isolation from electric lines in the building, prevent partial lightning currents from penetrating into control and supply lines and hence protect sensitive electrical and electronic dev ...
Pulse and Digital Circuits Lab MANUAL ONLY FOR REFERENCE
Pulse and Digital Circuits Lab MANUAL ONLY FOR REFERENCE

... In positive clipping circuit positive cycle of Sinusoidal signal is clipped and negative portion of sinusoidal signal is obtained in the output of reference voltage is added, instead of complete positive cycle that portion of the positive cycle which is above the reference voltage value is clipped. ...
Assessing an EM environment
Assessing an EM environment

... low-level magnetic fields, which may be many tens of meters from power, telecomm, or data cables. Sensitive circuits (those using low levels of current and/or voltage for their signals) are more likely to be susceptible. Sparks at metal connections carrying circulating currents due to strong magneti ...
TPA2031D1 数据资料 dataSheet 下载
TPA2031D1 数据资料 dataSheet 下载

... Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. NanoFree is a trademark of Texas Instruments. ...
Stearns SINPAC Electronic Switches
Stearns SINPAC Electronic Switches

... They cut out the start circuit at approximately 80% of synchronous speed*. This means no degradation in motor performance and no confusing and cumbersome time or current selection criteria to consider, since SINPAC Switches are not load sensitive. It also means there will be less stress on the start ...
LM4120 - Texas Instruments
LM4120 - Texas Instruments

TXS0206A SD Card Voltage-Translation
TXS0206A SD Card Voltage-Translation

... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
SHOT AND THERMAL NOISE
SHOT AND THERMAL NOISE

... (resistance, bandwidth, voltage, temperature) need to be scrutinized. The following points are just some of many considerations to think about. • The noise resistors (in the resistor bank) can be measured quite accurately with a DMM, but the effects of other resistances in parallel should be evaluat ...
LOW-NOISE ADSL DUAL DIFFERENTIAL RECEIVER THS6062
LOW-NOISE ADSL DUAL DIFFERENTIAL RECEIVER THS6062

... The THS6062 is a high-speed differential receiver designed for ADSL data communication systems. Its very low 1.6 nV/√Hz voltage noise provides the high signal-to-noise ratios necessary for the long transmission lengths of ADSL systems over copper telephone lines. In addition, this receiver operates ...
MARK - Specialty Concepts
MARK - Specialty Concepts

Strategic Master Plan For South Pole Energy
Strategic Master Plan For South Pole Energy

... Circuit Capacity: Circuit capacity is a function of the rating of the breaker, the load it is serving, and the equipment served. For example, a feeder supplying only transformers has to be sized for the nameplate capacity of the transformers served (NEC 215 B 1). If the feeder serves transformers in ...
IEEE Std 519™-2014, IEEE Recommended Practice and
IEEE Std 519™-2014, IEEE Recommended Practice and

K20 Sub-Family
K20 Sub-Family

... to VDD. If VIN greater than VDIO_MIN (=VSS-0.3V) is observed, then there is no need to provide current limiting resistors at the pads. If this limit cannot be observed then a current limiting resistor is required. The negative DC injection current limiting resistor is calculated as R=(VDIO_MIN-VIN)/ ...
UWE Series - power, Murata
UWE Series - power, Murata

... can plug directly into quarter-brick pinouts. Several standard fixed-output voltages from 3.3 Vdc to 24 Vdc assure compatibility in embedded equipment, CPU cards and instrument subsystems. The extended 4-to-1 input power range (9-36V) is ideal for battery-powered, telecom or portable applications. Ve ...
EEC 126 Instrumentation 1-Theory - Unesco
EEC 126 Instrumentation 1-Theory - Unesco

... instruments which will indicate the electrical quantities present. The instruments used to measure these electrical quantities (e.g. current, voltage, resistance, power, etc.) are called electrical/electronic instruments. These instruments are generally named after the electrical quantity to be meas ...
Equipment Life Extension and Modernization of Generator
Equipment Life Extension and Modernization of Generator

... current and the other to produce the required transient recovery voltage. These circuits were originally developed to test transmission class circuit breakers, rated 100 kV and above. Although the synthetic test method is not new, it is complicated, owing to the need to control the precise operation ...
CURTIS PMC 235 East Airway Boulevard Livermore, California
CURTIS PMC 235 East Airway Boulevard Livermore, California

... High pedal disable (HPD) function monitors throttle status during turn-on and prevents operation until throttle has been returned to neutral [optional feature] Thermal protection and compensation circuit provides both undertemperature and overtemperature cutback, as well as steady current limit ...
Advantages of Solid-State Relays Over Electro
Advantages of Solid-State Relays Over Electro

... them, the type of load, operating frequency, atmosphere, contact arrangement, and contact bounce. If any of these values fails to satisfy a predetermined limit, problems such as metal degradation between contacts, contact welding, wear, or a rapid increase in contact resistance can occur. Contact we ...
Methods to Increase Line Relay Loadability
Methods to Increase Line Relay Loadability

MAX17000 Complete DDR2 and DDR3 Memory Power-Management Solution General Description
MAX17000 Complete DDR2 and DDR3 Memory Power-Management Solution General Description

... high-efficiency, constant-on-time PWM controller handles wide input/output voltage ratios (low duty-cycle applications) with ease and provides 100ns response to load transients while maintaining a relatively constant switching frequency. The Quick-PWM architecture circumvents the poor load-transient ...
001
001

< 1 ... 72 73 74 75 76 77 78 79 80 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report