• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TBU-DT085-300-WH Datasheet
TBU-DT085-300-WH Datasheet

... the figure below. The TBU® protector prevents any surges from causing damage. An overvoltage protection device, such as an MOV or GDT, may be used to provide additional overvoltage protection if the surge voltage is likely to be above the maximum rating of the TBU® device. ...
wireless and carrier communication based smart metering
wireless and carrier communication based smart metering

... These involves all elements and parts of the hardware are derived analytically and verified by simulation before them use in hardware. Choice of component values is based upon knowing the standard guide voltage, power frequency, harmonic destruction and short time over voltages. As smart meters are ...
UC3851 数据资料 dataSheet 下载
UC3851 数据资料 dataSheet 下载

... and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s te ...
Bulletin CW500-01EN CW500 Power Quality Analyzer
Bulletin CW500-01EN CW500 Power Quality Analyzer

... and waveforms. Additionally there is a digital output on occurrence. Long period malfunctions can be analyzed by harmonics, flicker, waveform or checking on the unbalance rate calculation for 3 phase measurement. All data can be finalized to a report format with included software. The CW500 conforms ...
6.0 Electrical Installations - Department of Electrical Engineering
6.0 Electrical Installations - Department of Electrical Engineering

... protection, etc., is greatly affected by the state of the neutral conductor. When the neutral is properly grounded, voltages of the phases are limited to near phase to ground voltage. Equipment earthing: This refers to grounding of all metal work of equipment other than the parts which are normally ...
Low Sensitivity Third Order Lowpass Butterworth Filter Using CFA
Low Sensitivity Third Order Lowpass Butterworth Filter Using CFA

... the high−frequency model of the AD−844 CFA device; the passive−RC components of the circuit had then been approximately chosen to obtain a normalised filter function [12]. The effect of rx (≈ 40Ω) at the x−node of the device had been neglected since rx can be virtually eleminated in some improved [4 ...
Multisim Tutorial
Multisim Tutorial

ELECTROMOTIVE FORCE AND POTENTIAL DIFFERENCE
ELECTROMOTIVE FORCE AND POTENTIAL DIFFERENCE

TBU-DT085-100-WH
TBU-DT085-100-WH

... the figure below. The TBU® protector prevents any surges from causing damage. An overvoltage protection device, such as an MOV or GDT, may be used to provide additional overvoltage protection if the surge voltage is likely to be above the maximum rating of the TBU® device. ...
MULTISIM Instruction Manual
MULTISIM Instruction Manual

... All circuits must be grounded before the circuit can be simulated. Click on Ground in the toolbar to ground the circuit. If the circuit is not grounded Multisim will not run the simulation. ...
Heating in Aluminum Electrolytic Strobe and Photoflash Capacitors
Heating in Aluminum Electrolytic Strobe and Photoflash Capacitors

... is temperature. In practice, RSP varies only with temperature, up to a fairly high frequency at which In most applications, there is a ripple current at 50 rolloff begins; this frequency is a function of the Hz or higher, and the resulting AC voltage is small, foil etch structure and the electrolyte ...
EXPERIMENT NO
EXPERIMENT NO

... Passive components are ones which cannot introduce net energy into the circuit they are connected to. They also cannot rely on a source of power except for what is available from the (AC) circuit they are connected to. As a consequence they are unable to amplify (increase the power of a signal), alt ...
PRESENTATION ON SUBSTATION DESIGN AND CONSTRUCTION
PRESENTATION ON SUBSTATION DESIGN AND CONSTRUCTION

...  Disconnect switches are also installed to by pass breakers or other equipment for maintenance.  They are designed for no-load switching. Key Requirements  Open and Close reliably whenever necessary  Carry current continuously without overheating  To remain in the closed position under fault cu ...
ST NE556
ST NE556

... General-purpose dual bipolar timers Features ...
NCP432 - Ultra Small Controlled Load Switch with Auto
NCP432 - Ultra Small Controlled Load Switch with Auto

AD8509 数据手册DataSheet 下载
AD8509 数据手册DataSheet 下载

... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ab ...
9- and 11-Channel, Muxed Input LCD Reference Buffers AD8509/AD8511
9- and 11-Channel, Muxed Input LCD Reference Buffers AD8509/AD8511

... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ab ...
I`—® I__liIiji IJ
I`—® I__liIiji IJ

... Figure 5a represents a circuit that Cherise constructed to test the conductivity of varidus objects in her home, Figure 5b shows how she connected the objects to be tested across terminals X and Y with the ...
DM7476 Dual Master-Slave J-K Flip-Flops with Clear, Preset, and
DM7476 Dual Master-Slave J-K Flip-Flops with Clear, Preset, and

... transferred to the slave. The logic state of J and K inputs must not be allowed to change while the clock is HIGH. The data is transferred to the outputs on the falling edge of the clock pulse. A LOW logic level on the preset or clear inputs will set or reset the outputs regardless of the logic leve ...
LM555 LM555C Timer - Elektronik
LM555 LM555C Timer - Elektronik

... application of a trigger pulse will not effect the circuit so long as the trigger input is returned high at least 10 ms before the end of the timing interval. However the circuit can be reset during this time by the application of a negative pulse to the reset terminal (pin 4). The output will then ...
LM555/LM555C Timer
LM555/LM555C Timer

... application of a trigger pulse will not effect the circuit so long as the trigger input is returned high at least 10 ms before the end of the timing interval. However the circuit can be reset during this time by the application of a negative pulse to the reset terminal (pin 4). The output will then ...
+ R - UCSD Physics
+ R - UCSD Physics

... 1. ∆V increases by 2V in the direction of I. What is ∆V across the 2. ∆V decreases by 2V in the direction of I. ...
micom P342 / 343 / 344 / 345
micom P342 / 343 / 344 / 345

... A third harmonic neutral over voltage protection is also provided for applications where the measurement is available at the terminal end of the generator. The blocking features of the under voltage lement are not required for this application. 100% stator ground fault low frequency injection method ...
Testing Ethernet Ports including Power Over Ethernet (802.3at and
Testing Ethernet Ports including Power Over Ethernet (802.3at and

... 1500 Vrms “hipot” insulation test. These transformers often fail a 1500 Vrms “hipot” insulation test and have caused field failures in office installations. The invalid argument some transformer manufacturers use is that the 1500 V rms test is for the port; it is up the designer to make the port mee ...
Schmitt trigger package
Schmitt trigger package

... What is likely to happen to the output of an op-amp comparator if the signal is noisy at the switching voltage? ...
< 1 ... 680 681 682 683 684 685 686 687 688 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report