Full Text - ARPN Journals
... L. Huber, Y. Jang and M.M. Jovanovic [5] in the year 2008 proposed a paper based on cuk converter based BLDC. In this section, the topology derivation of the proposed converter is presented. Figure-3 shows a modified Cuk converter also known as a “Self-lift Cuk” converter. Referring to Figure-3, the ...
... L. Huber, Y. Jang and M.M. Jovanovic [5] in the year 2008 proposed a paper based on cuk converter based BLDC. In this section, the topology derivation of the proposed converter is presented. Figure-3 shows a modified Cuk converter also known as a “Self-lift Cuk” converter. Referring to Figure-3, the ...
MAX16010–MAX16014 Ultra-Small, Overvoltage Protection/ Detection Circuits General Description
... Ultra-Small, Overvoltage Protection/ Detection Circuits The MAX16010–MAX16014 is a family of ultra-small, lowpower, overvoltage protection circuits for high-voltage, high-transient systems such as those found in automotive, telecom, and industrial applications. These devices operate over a wide 5.5V ...
... Ultra-Small, Overvoltage Protection/ Detection Circuits The MAX16010–MAX16014 is a family of ultra-small, lowpower, overvoltage protection circuits for high-voltage, high-transient systems such as those found in automotive, telecom, and industrial applications. These devices operate over a wide 5.5V ...
Brochure
... current that can be present at any point in an electric system is crucial to ensure the system’s reliability. The abnormal current level produced by faults put an important stress on the electrical equipment, and if the latter are not properly rated, it could lead to equipment damage, personnel inju ...
... current that can be present at any point in an electric system is crucial to ensure the system’s reliability. The abnormal current level produced by faults put an important stress on the electrical equipment, and if the latter are not properly rated, it could lead to equipment damage, personnel inju ...
High Voltage Products
... interrupter unit, only low actuating forces are required. • Availability and long service life: Minimal stressing of the latch mechanisms and rolling-contact bearings in the operating mechanism ensure reliable and wear-free transmission of forces. • Maintenance-free design: The spring charging gea ...
... interrupter unit, only low actuating forces are required. • Availability and long service life: Minimal stressing of the latch mechanisms and rolling-contact bearings in the operating mechanism ensure reliable and wear-free transmission of forces. • Maintenance-free design: The spring charging gea ...
AH293 LOW VOLTAGE HALL-EFFECT SMART FAN MOTOR CONTROLLER
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
SVRFL2800S Datasheet
... tightly regulated positive output voltage with respect to the OUTCOM pin. Feedback isolation is accomplished using VPT’s proprietary magnetic feedback technology. The converter regulates with zero load, and no minimum load is required. 6.1.2 External Components The SVRFL2800S Series is designed to o ...
... tightly regulated positive output voltage with respect to the OUTCOM pin. Feedback isolation is accomplished using VPT’s proprietary magnetic feedback technology. The converter regulates with zero load, and no minimum load is required. 6.1.2 External Components The SVRFL2800S Series is designed to o ...
Inside iCoupler® Technology: Polyimide Insulation Layer By
... free of voids and do not suffer from corona discharge, iCoupler devices also exhibit good aging behavior and work well under continuous ac voltages and dc voltages. Besides good high voltage performance, polyimide has excellent ESD performance, capable of handling EOS and ESD events exceeding 15 kV. ...
... free of voids and do not suffer from corona discharge, iCoupler devices also exhibit good aging behavior and work well under continuous ac voltages and dc voltages. Besides good high voltage performance, polyimide has excellent ESD performance, capable of handling EOS and ESD events exceeding 15 kV. ...
Machine and Pane Level Solutions
... programmable undervoltage element. This provides a selectable backup feature if a manual or protective relay transfer is not initiated. ...
... programmable undervoltage element. This provides a selectable backup feature if a manual or protective relay transfer is not initiated. ...
17 Tips-Tricks.indd
... terminal we can sense the voltage on the device and compensate for any voltage drop in the probes or test leads. Figure 12 shows a large MOSFET; we want to measure the characteristics of the drain. We’ve added a 10Ω resistor in series with the source in order to simulate excessive test probe resista ...
... terminal we can sense the voltage on the device and compensate for any voltage drop in the probes or test leads. Figure 12 shows a large MOSFET; we want to measure the characteristics of the drain. We’ve added a 10Ω resistor in series with the source in order to simulate excessive test probe resista ...
RT8239A/B/C
... Note 1. Stresses beyond those listed “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Ex ...
... Note 1. Stresses beyond those listed “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Ex ...
ADM3307E 数据手册DataSheet 下载
... fully meet the EIA-232 standard while operating with a single 2.7 V to 3.6 V power supply. The devices feature an on-board charge pump dc-to-dc converter, eliminating the need for dual power supplies. This dc-to-dc converter contains a voltage tripler and a voltage inverter that internally generates ...
... fully meet the EIA-232 standard while operating with a single 2.7 V to 3.6 V power supply. The devices feature an on-board charge pump dc-to-dc converter, eliminating the need for dual power supplies. This dc-to-dc converter contains a voltage tripler and a voltage inverter that internally generates ...
TMP01 数据手册DataSheet 下载
... The accuracy of the VPTAT sensor output is well characterized and specified; however, preserving this accuracy in a heating or cooling control system requires some attention to minimizing the various potential error sources. The internal sources of setpoint programming error include the initial tole ...
... The accuracy of the VPTAT sensor output is well characterized and specified; however, preserving this accuracy in a heating or cooling control system requires some attention to minimizing the various potential error sources. The internal sources of setpoint programming error include the initial tole ...
ADA4420-6 数据手册DataSheet 下载
... range of 0 V to 2.1 V. When using ac-coupled inputs, the lowest point of the signal is clamped to approximately 0 V. The ADA4420-6 outputs can be either ac- or dc-coupled. When driving single ac-coupled loads in standard 75 Ω video distribution systems, a minimum capacitance of 220 μF is recommended ...
... range of 0 V to 2.1 V. When using ac-coupled inputs, the lowest point of the signal is clamped to approximately 0 V. The ADA4420-6 outputs can be either ac- or dc-coupled. When driving single ac-coupled loads in standard 75 Ω video distribution systems, a minimum capacitance of 220 μF is recommended ...
TRANSMISSION INTERCONNECTIONS Most of the world`s electric
... such resonance persists, it will soon damage the shaft. Also while the outage of one line forces other lines to operate at their emergency ratings and carry higher loads, power flow oscillations at low frequency (typically 0.3-3 Hz) may cause generators to lose synchronism, perhaps prompting the sys ...
... such resonance persists, it will soon damage the shaft. Also while the outage of one line forces other lines to operate at their emergency ratings and carry higher loads, power flow oscillations at low frequency (typically 0.3-3 Hz) may cause generators to lose synchronism, perhaps prompting the sys ...
Tantalum & Niobium Capacitors Technical Standards and Benefits
... Protection against uneven current surges in low impedance circuits is the most important factor to consider an appropriate derating factor of tantalum capacitor. The worst case of current surge in the application should not exceed the design and screened current of the capacitor specified by the man ...
... Protection against uneven current surges in low impedance circuits is the most important factor to consider an appropriate derating factor of tantalum capacitor. The worst case of current surge in the application should not exceed the design and screened current of the capacitor specified by the man ...
BD6967FVM
... can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute maximum ratings, consider adding circuit protection devices, such as fuses. Connecting the power supply connector back ...
... can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute maximum ratings, consider adding circuit protection devices, such as fuses. Connecting the power supply connector back ...
MAX17019 Evaluation Kit Evaluates: General Description Features
... MAX17019 high input-voltage quad-output controller in a typical application setup. The EV kit operates from a 5.5V to 38V input range. The high input voltage of 38V makes this device ideal for automotive applications. High-voltage controller A is used to generate a 5V rail that serves as supply for ...
... MAX17019 high input-voltage quad-output controller in a typical application setup. The EV kit operates from a 5.5V to 38V input range. The high input voltage of 38V makes this device ideal for automotive applications. High-voltage controller A is used to generate a 5V rail that serves as supply for ...
Three Level Inverter Based Shunt Active Power Filter Using Multi
... controlled voltage source. Traditionally, shunt APFs are implemented using VSI based two-level inverters. Such APFs use a transformer to meet desired voltage profile [11]. The transformer leads to increasing the losses in the system and it may saturate once the load draws any DC current. Further at ...
... controlled voltage source. Traditionally, shunt APFs are implemented using VSI based two-level inverters. Such APFs use a transformer to meet desired voltage profile [11]. The transformer leads to increasing the losses in the system and it may saturate once the load draws any DC current. Further at ...
Omnitronix EventSensor Manual
... Sensor Name is a custom alias to be used when reporting events detected via this sensor. Contact Closure Enabled is an ON/OFF toggle used to enable or disable a particular sensor. Contact Closure Enabled is an ON/OFF toggle for this particular sensor. Event State is an OPEN/CLOSED toggle that determ ...
... Sensor Name is a custom alias to be used when reporting events detected via this sensor. Contact Closure Enabled is an ON/OFF toggle used to enable or disable a particular sensor. Contact Closure Enabled is an ON/OFF toggle for this particular sensor. Event State is an OPEN/CLOSED toggle that determ ...
High Speed PWM Controller
... enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products ...
... enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products ...
Extending the MFJ-927 to 160-Meters
... the entire coil assembly for 80-10 meter operation (0VDC applied), or insert the entire coil assembly for 160 meter operation (+12VDC applied). The vacuum relay is necessary as the majority of the high feed-point voltage will occur across the un-shorted inductor on 160 meters. I also added a second ...
... the entire coil assembly for 80-10 meter operation (0VDC applied), or insert the entire coil assembly for 160 meter operation (+12VDC applied). The vacuum relay is necessary as the majority of the high feed-point voltage will occur across the un-shorted inductor on 160 meters. I also added a second ...
L-11 Back emf - Synergy Dhenkanal
... When d.c. voltage V is applied across the motor terminals, the field magnets are excited and armature conductors are supplied with current. Therefore, driving torque acts on the armature which begins to rotate. As the armature rotates, back e.m.f. Eb is induced which opposes the applied voltage V. T ...
... When d.c. voltage V is applied across the motor terminals, the field magnets are excited and armature conductors are supplied with current. Therefore, driving torque acts on the armature which begins to rotate. As the armature rotates, back e.m.f. Eb is induced which opposes the applied voltage V. T ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".