Methods of Analysis
... connected between two nonreference nodes – The two nodes form a supernode – Apply KCL to the supernode (similar to a closed boundary) – Apply KVL to derive the relationship between the two nodes ...
... connected between two nonreference nodes – The two nodes form a supernode – Apply KCL to the supernode (similar to a closed boundary) – Apply KVL to derive the relationship between the two nodes ...
ADM2914 数据手册DataSheet 下载
... 0.5 V, an overvoltage condition is detected. Tie to GND when not in use. Voltage High Input 3 and Voltage High Input 4. The polarity of these inputs is determined by the state of the SEL pin (see Table 5). When the monitored input is configured as a positive voltage and the voltage monitored by VH3 ...
... 0.5 V, an overvoltage condition is detected. Tie to GND when not in use. Voltage High Input 3 and Voltage High Input 4. The polarity of these inputs is determined by the state of the SEL pin (see Table 5). When the monitored input is configured as a positive voltage and the voltage monitored by VH3 ...
DC Drive Selection Guide
... Current, Motor Armature Voltage, Analog Input Voltage, Control Mode (Speed or Torque) and Coast to Stop (CTS) or Regenerate to Stop (RTS). The Overspeed Protect Circuit prevents failure of the power bridge in extreme overhauling conditions. Reliability of the KBMG is further enhanced with the use of ...
... Current, Motor Armature Voltage, Analog Input Voltage, Control Mode (Speed or Torque) and Coast to Stop (CTS) or Regenerate to Stop (RTS). The Overspeed Protect Circuit prevents failure of the power bridge in extreme overhauling conditions. Reliability of the KBMG is further enhanced with the use of ...
TG50E - CE Niehoff Co.
... These batteries respond better than standard maintenance-free. Charge acceptance of these batteries may display characteristics similar to maintenance batteries. • AGM (Absorbed Glass Mat) Maintenance-free Battery These dry-cell batteries respond better than standard maintenance-free. If battery st ...
... These batteries respond better than standard maintenance-free. Charge acceptance of these batteries may display characteristics similar to maintenance batteries. • AGM (Absorbed Glass Mat) Maintenance-free Battery These dry-cell batteries respond better than standard maintenance-free. If battery st ...
DMN2005LP4K Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
BQ20Z40-R1 数据资料 dataSheet 下载
... bq20z40-R1 monitors capacity change, battery impedance, open-circuit voltage, and other critical parameters of the battery pack, and reports the information to the system host controller over a serial-communication bus. It is designed to work with the bq29330 analog front-end (AFE) protection IC to ...
... bq20z40-R1 monitors capacity change, battery impedance, open-circuit voltage, and other critical parameters of the battery pack, and reports the information to the system host controller over a serial-communication bus. It is designed to work with the bq29330 analog front-end (AFE) protection IC to ...
Mini-project report 1 Analysis and Design of Electronic Load
... Circuit protection devices are required to protect wires, connections and electrical equipment from an over current, e.g. short circuit. Excess current leads to excess heat or leakage current that makes the circuit protection devices open the circuit. This in turn also protects the people operating ...
... Circuit protection devices are required to protect wires, connections and electrical equipment from an over current, e.g. short circuit. Excess current leads to excess heat or leakage current that makes the circuit protection devices open the circuit. This in turn also protects the people operating ...
P84398
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
LTC4059
... Amplifiers CA and VA are used in separate feedback loops to force the charger into constant-current or voltage mode, respectively. Diodes D1 and D2 provide priority to either the constant-current or constant-voltage loop; whichever is trying to reduce the charge current the most. The output of the o ...
... Amplifiers CA and VA are used in separate feedback loops to force the charger into constant-current or voltage mode, respectively. Diodes D1 and D2 provide priority to either the constant-current or constant-voltage loop; whichever is trying to reduce the charge current the most. The output of the o ...
FXMAR2104 Dual-Supply, 4-Bit Voltage Translator / Isolator for Open-Drain and Push-Pull Applications
... specification voltage levels. Eight internal 10KΩ pull-up resistors are integrated. The device is designed so that the A port tracks the VCCA level and the B port tracks the VCCB level. This allows for bi-directional A/B port voltage translation between any two levels from 1.65V to 5.5V. VCCA can eq ...
... specification voltage levels. Eight internal 10KΩ pull-up resistors are integrated. The device is designed so that the A port tracks the VCCA level and the B port tracks the VCCB level. This allows for bi-directional A/B port voltage translation between any two levels from 1.65V to 5.5V. VCCA can eq ...
The Generalized Discontinuous PWM Scheme for Three
... improved, the linear modulation range can be extended, and common mode voltage of motor drives fed from the converters can also be drastically diminished. These potentials have been explored leading to investigations into and determination of various zero-sequence waveforms, resulting in a large num ...
... improved, the linear modulation range can be extended, and common mode voltage of motor drives fed from the converters can also be drastically diminished. These potentials have been explored leading to investigations into and determination of various zero-sequence waveforms, resulting in a large num ...
Zahn, M., Transient Drift Dominated Unipolar Conduction Between Concentric Cylinders and Spheres, IEEE Transactions on Electrical Insulation, EI-11, 150-157, 1976
... These three cases indicate the possible field and charge distributions. For small emitter electric fields (pi < (1 - kd-1), the emitted charge density is large, and the electric field is an increasing function of radial position while the charge density is a decreasing function of radial position. I ...
... These three cases indicate the possible field and charge distributions. For small emitter electric fields (pi < (1 - kd-1), the emitted charge density is large, and the electric field is an increasing function of radial position while the charge density is a decreasing function of radial position. I ...
A Door Motion Energy Harvesting System for Powering an Electronic
... As shown in Table 1, the motor constant for the chosen gear motor is 0.91 V/rpm. At a typical rotational speed of 7.5rpm, an open-circuit voltage of about 6.8V would be produced. The maximum power transfer would therefore occur when the generator output terminals were loaded to produce a voltage of ...
... As shown in Table 1, the motor constant for the chosen gear motor is 0.91 V/rpm. At a typical rotational speed of 7.5rpm, an open-circuit voltage of about 6.8V would be produced. The maximum power transfer would therefore occur when the generator output terminals were loaded to produce a voltage of ...
MAX767 5V-to-3.3V, Synchronous, Step-Down Power-Supply Controller ________________General Description
... Note: The remainder of this document contains the detailed information necessary to design a circuit that differs substantially from the five standard application circuits. If you are using one of the predesigned standard circuits, the following sections are provided only for your reading pleasure. ...
... Note: The remainder of this document contains the detailed information necessary to design a circuit that differs substantially from the five standard application circuits. If you are using one of the predesigned standard circuits, the following sections are provided only for your reading pleasure. ...
PAM2401 Description Pin Assignments
... current limiting. The device includes one 0.10Ω N-channel MOSFET switch and one 0.15Ω P-channel synchronous rectifier. This product has the ability to simply program the output voltage from 2.5V to ...
... current limiting. The device includes one 0.10Ω N-channel MOSFET switch and one 0.15Ω P-channel synchronous rectifier. This product has the ability to simply program the output voltage from 2.5V to ...
Single phase controller with digital interface
... regulation. When external reference is set through MFR_SETTINGS command, the REFIN becomes an input (direct or divided by 2). The external reference voltage connected is then used as a reference for the control loop feedback, the soft-start ramp, the margining magnitude, and all the output voltage r ...
... regulation. When external reference is set through MFR_SETTINGS command, the REFIN becomes an input (direct or divided by 2). The external reference voltage connected is then used as a reference for the control loop feedback, the soft-start ramp, the margining magnitude, and all the output voltage r ...
Low-Ripple 1.8V/1.6V Spread-Spectrum
... specified input voltage, output current, and ambient temperature operating ratings. If thermal cycling is seen under these conditions, the most likely cause is an inadequate PCB layout that does not allow heat to be sufficiently dissipated out of the DSBGA package. Current Limit Protection The LM277 ...
... specified input voltage, output current, and ambient temperature operating ratings. If thermal cycling is seen under these conditions, the most likely cause is an inadequate PCB layout that does not allow heat to be sufficiently dissipated out of the DSBGA package. Current Limit Protection The LM277 ...
S260-15-2
... Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER: Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all loca ...
... Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER: Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all loca ...
B 2.5 A Output Current, IGBT Drive Optocoupler with Desaturation Detection
... The internal gate driving circuitry of FOD8316 can be used with either a single positive power supply, VDD2, or a dual positive and negative supply, VDD2 and VSS. The output driver stage, VO, is made up of a pair of PMOS and NMOS transistors, which facilitates close to rail-to-rail output swing. Thi ...
... The internal gate driving circuitry of FOD8316 can be used with either a single positive power supply, VDD2, or a dual positive and negative supply, VDD2 and VSS. The output driver stage, VO, is made up of a pair of PMOS and NMOS transistors, which facilitates close to rail-to-rail output swing. Thi ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".