Evaluates: MAX5092B/92A/MAX5093B/93A MAX5092 Evaluation Kit General Description Features
... switching diode (D1) connected between LX and BSOUT (Figure 2). Proper selection of an external diode can offer a lower forward-voltage drop and a higher reverse-voltage handling capability. Since the high-switching frequency of the IC demands a highspeed rectifier, Schottky diodes are recommended f ...
... switching diode (D1) connected between LX and BSOUT (Figure 2). Proper selection of an external diode can offer a lower forward-voltage drop and a higher reverse-voltage handling capability. Since the high-switching frequency of the IC demands a highspeed rectifier, Schottky diodes are recommended f ...
WATER COOLED POWER TETRODE 8974
... HANDLING – This product contains a thoriated-tungsten filament, and although of a rugged mesh design, it is relatively fragile and a tube should be protected from shock and vibration. A lifting eye is available at the center of the anode cooler and should be used any time the tube is to be lifted fo ...
... HANDLING – This product contains a thoriated-tungsten filament, and although of a rugged mesh design, it is relatively fragile and a tube should be protected from shock and vibration. A lifting eye is available at the center of the anode cooler and should be used any time the tube is to be lifted fo ...
TPA2008D2 数据资料 dataSheet 下载
... The main reason that the traditional class-D amplifier needs an output filter is that the switching waveform results in maximum current flow. This causes more loss in the load, which causes lower efficiency. The ripple current is large for the traditional modulation scheme, because the ripple curren ...
... The main reason that the traditional class-D amplifier needs an output filter is that the switching waveform results in maximum current flow. This causes more loss in the load, which causes lower efficiency. The ripple current is large for the traditional modulation scheme, because the ripple curren ...
ST6 - CONTROLLING A BRUSH DC MOTOR WITH AN ST6265
... otherwise fully software. Our application features a 300 watts maximum power, but this value can be easily adjusted by modifying a data table in the program, therefore allowing a very short design modification time if the drive must be used with various motors. 2 WHY USE a MICROCONTROLLER? The class ...
... otherwise fully software. Our application features a 300 watts maximum power, but this value can be easily adjusted by modifying a data table in the program, therefore allowing a very short design modification time if the drive must be used with various motors. 2 WHY USE a MICROCONTROLLER? The class ...
Film Capacitors – Power Factor Correction - MKK440-D-50
... again. This prevents an electric impulse discharge in the application, influences the capacitor’s service life and protects against electric shock. The capacitor must be discharged to 75 V or less within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit b ...
... again. This prevents an electric impulse discharge in the application, influences the capacitor’s service life and protects against electric shock. The capacitor must be discharged to 75 V or less within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit b ...
Design of high-speed, low-power frequency dividers and phase
... bipolar and III-V devices. These trade-offs are nonetheless relaxed as device dimensions scale down, making deep submicron CMOS attractive even for multigigahertz circuits. This can ultimately lead to monolithic integration of communication systems that include high-speed input and output interfaces ...
... bipolar and III-V devices. These trade-offs are nonetheless relaxed as device dimensions scale down, making deep submicron CMOS attractive even for multigigahertz circuits. This can ultimately lead to monolithic integration of communication systems that include high-speed input and output interfaces ...
Frequently Asked Questions About Our Cooling And
... cost/benefit or design engineering considerations which are unique to each application. Given the present state of technology—unless there are unique overriding concerns—the compressorbased approach has distinct advantages in larger cooling systems such as standard-sized refrigerators and air-condit ...
... cost/benefit or design engineering considerations which are unique to each application. Given the present state of technology—unless there are unique overriding concerns—the compressorbased approach has distinct advantages in larger cooling systems such as standard-sized refrigerators and air-condit ...
1) INTRODUCTION
... the excess current from the solar array. The charge control algorithm regulates the acceleration of the flywheel motor so that the DC current is maintained at the commanded set point. There are two components to the controller: the proportional-integral (PI) and the feed-forward (FF). The feedforwar ...
... the excess current from the solar array. The charge control algorithm regulates the acceleration of the flywheel motor so that the DC current is maintained at the commanded set point. There are two components to the controller: the proportional-integral (PI) and the feed-forward (FF). The feedforwar ...
Highly Efficient, and Compact ZVS Resonant Full Bridge Converter
... Thirdly, the clamping diodes and voltage sources are introduced to maintain an equal voltage stress distribution among these two series switches to account for the presence of intrinsic differences among devices. The clamping voltage source is equal to the voltage stress magnitude of the basic conve ...
... Thirdly, the clamping diodes and voltage sources are introduced to maintain an equal voltage stress distribution among these two series switches to account for the presence of intrinsic differences among devices. The clamping voltage source is equal to the voltage stress magnitude of the basic conve ...
Design Comparison of Round and Rectangular Wire Winding
... Index Terms—Distribution transformer, step core, core type, round and rectangular, tank and temperature rise. I. INTRODUCTION A transformer is a static device that transfers electrical energy from one circuit to another by electromagnetic induction without the change in frequency. The transformer, w ...
... Index Terms—Distribution transformer, step core, core type, round and rectangular, tank and temperature rise. I. INTRODUCTION A transformer is a static device that transfers electrical energy from one circuit to another by electromagnetic induction without the change in frequency. The transformer, w ...
UT54ACS169 - Aeroflex Microelectronic Solutions
... 1.Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: VIH = VIH(min) + 20%, - 0%; VIL = VIL(max) + 0%, 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified r ...
... 1.Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: VIH = VIH(min) + 20%, - 0%; VIL = VIL(max) + 0%, 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified r ...
ISO150 数据资料 dataSheet 下载
... Nominal rated supply voltage is 5 V. Operation extends from 3 V to 5.5 V. Power supplies should be bypassed close to the device pins on both sides of the isolation barrier. The VS pin for each side powers the transceivers for both channel 1 and 2. The specified supply current is the total of both tr ...
... Nominal rated supply voltage is 5 V. Operation extends from 3 V to 5.5 V. Power supplies should be bypassed close to the device pins on both sides of the isolation barrier. The VS pin for each side powers the transceivers for both channel 1 and 2. The specified supply current is the total of both tr ...
NAT0000X12RXX SIP Non-Isolated Point-of
... frame design with integrated magnetics has a low profile (0.25’’), achieving industry-leading power density and enhanced airflow for nearby components. As a benefit of the high efficiency and resulting superior thermal performance, these converters can provide high output currents in challenging env ...
... frame design with integrated magnetics has a low profile (0.25’’), achieving industry-leading power density and enhanced airflow for nearby components. As a benefit of the high efficiency and resulting superior thermal performance, these converters can provide high output currents in challenging env ...
DS-100C I-V CURVE TRACER User Manual
... Note: The three measurement voltage ranges listed here should not be confused with the load ranges (VHIGH and VLOW) selected with the range switch. A computer running the IVPC for Windows program controls the DS-Tracer. (See the IVPC Reference Manual). The computer running the IVPC application may b ...
... Note: The three measurement voltage ranges listed here should not be confused with the load ranges (VHIGH and VLOW) selected with the range switch. A computer running the IVPC for Windows program controls the DS-Tracer. (See the IVPC Reference Manual). The computer running the IVPC application may b ...
CURRICULUM VITAE - Northeastern University
... A. Shrivastava, Y. Ramadass, and S. Bartling “Single inductor energy management and harvesting interface system and method” US Patent Application Number: 20140103728. A. Shrivastava, “Output buffer with improved output signal quality” US Patent Application Number: ...
... A. Shrivastava, Y. Ramadass, and S. Bartling “Single inductor energy management and harvesting interface system and method” US Patent Application Number: 20140103728. A. Shrivastava, “Output buffer with improved output signal quality” US Patent Application Number: ...
2008 28 Autumn Wiring Matters
... Non-sheathed cables in conduit mounted on a Installation Method 70 of Table 4A2 wooden or masonry wallThe cable is drawn into a 100 mm diameter plastic, earthenware or metallic duct laid in direct contact with soil having a thermal resistivity of 2.5 K.m/W and at a depth of 0.8 m. The values given f ...
... Non-sheathed cables in conduit mounted on a Installation Method 70 of Table 4A2 wooden or masonry wallThe cable is drawn into a 100 mm diameter plastic, earthenware or metallic duct laid in direct contact with soil having a thermal resistivity of 2.5 K.m/W and at a depth of 0.8 m. The values given f ...
LTC490 - Linear Technology
... All of LTC’s RS485 products are protected against ESD transients up to 2kV using the human body model (100pF, 1.5kΩ). However, some applications need more protection. The best protection method is to connect a bidirectional TransZorb® from each line side pin to ground (Figure 11). A TransZorb is a s ...
... All of LTC’s RS485 products are protected against ESD transients up to 2kV using the human body model (100pF, 1.5kΩ). However, some applications need more protection. The best protection method is to connect a bidirectional TransZorb® from each line side pin to ground (Figure 11). A TransZorb is a s ...
User`s Guide True RMS Industrial Multimeter Extech EX530
... CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Set the function switch to the green VAC/Hz/% position. 2. Insert the black test lead banana plug into the negative COM jack. Insert red test lead b ...
... CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Set the function switch to the green VAC/Hz/% position. 2. Insert the black test lead banana plug into the negative COM jack. Insert red test lead b ...
Power Plant Electrical Distribution Systems
... medium voltage switchgears located in the plant. In this plant design there are two sets of switchgear buses rated at 6.9KV and 4160V. Each 6.9KV bus (shown in black) can be energized from the Unit Auxiliary Transformer. The same is true for the 4160V switchgear. There is another transformer shown i ...
... medium voltage switchgears located in the plant. In this plant design there are two sets of switchgear buses rated at 6.9KV and 4160V. Each 6.9KV bus (shown in black) can be energized from the Unit Auxiliary Transformer. The same is true for the 4160V switchgear. There is another transformer shown i ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".