16 Transformer and Transformer-feeder Protection
... e. system fault level The very high flux densities quoted above are so far beyond the normal working range that the incremental relative permeability of the core approximates to unity and the inductance of the winding falls to a value near that of the 'air-cored' inductance. The current wave, starti ...
... e. system fault level The very high flux densities quoted above are so far beyond the normal working range that the incremental relative permeability of the core approximates to unity and the inductance of the winding falls to a value near that of the 'air-cored' inductance. The current wave, starti ...
MAX14578E/MAX14578AE USB Battery Charger Detectors EVALUATION KIT AVAILABLE General Description
... BAT, INT, SDA, SCL, CE0, CE1, CE2, EN........... -0.3V to +6.0V LOUT............................................ -0.3V to (VB + 0.3V, 6V) (min) VB...........................................................................-0.3V to +30V Switch Disabled or CP_ENA = 1 (Note 1) CD+, CD-.................. ...
... BAT, INT, SDA, SCL, CE0, CE1, CE2, EN........... -0.3V to +6.0V LOUT............................................ -0.3V to (VB + 0.3V, 6V) (min) VB...........................................................................-0.3V to +30V Switch Disabled or CP_ENA = 1 (Note 1) CD+, CD-.................. ...
Fast fault detection for power distribution systems
... manner. The term is later defined based upon considerations and conclusions made in the first chapters and then related to a specific time. To be able to understand and appreciate why fast fault detection is necessary, power system faults and their consequences are briefly discussed. The consequences of ...
... manner. The term is later defined based upon considerations and conclusions made in the first chapters and then related to a specific time. To be able to understand and appreciate why fast fault detection is necessary, power system faults and their consequences are briefly discussed. The consequences of ...
Feedback in Amplifiers
... A negative feedback ensures stability and constant output In case of Wein bridge oscillator the negative feedback is provided through the voltage divider circuit in the output amplifier through resistances (say R3 and R4) in Wein bridge. Basically, a temperature sensitive tungsten lamp is used in pl ...
... A negative feedback ensures stability and constant output In case of Wein bridge oscillator the negative feedback is provided through the voltage divider circuit in the output amplifier through resistances (say R3 and R4) in Wein bridge. Basically, a temperature sensitive tungsten lamp is used in pl ...
OPERATIONAL AMPLIFIERS: BASIC CONCEPTS and COOKBOOK
... transistors. The transistor is indeed the basic element in any IC, but learning its working principle is not necessary for learning IC. In the modern analog electronic circuits, on the other hand, the basic building block is now the Operational Amplifier (OA), not the transistor. And understanding t ...
... transistors. The transistor is indeed the basic element in any IC, but learning its working principle is not necessary for learning IC. In the modern analog electronic circuits, on the other hand, the basic building block is now the Operational Amplifier (OA), not the transistor. And understanding t ...
Effects of Smoke on Functional Circuits NUREG/CR-6543 SAND97-2544
... The high-speed digital circuit was not affected by smoke, even at the highest fuel level. The main component tested in this circuit was an advanced TTL (FAST) chip. An experiment that compared the failure of chip technologies in the presence of a shunt resistance showed that a FAST chip is one of th ...
... The high-speed digital circuit was not affected by smoke, even at the highest fuel level. The main component tested in this circuit was an advanced TTL (FAST) chip. An experiment that compared the failure of chip technologies in the presence of a shunt resistance showed that a FAST chip is one of th ...
ISL55100B Datasheet
... Receiver Features The receivers are four independent window comparators that feature high output current capability and user defined high and low output levels to interface with a wide variety of logic families. Each receiver comprises two comparators and each comparator has an independent threshold ...
... Receiver Features The receivers are four independent window comparators that feature high output current capability and user defined high and low output levels to interface with a wide variety of logic families. Each receiver comprises two comparators and each comparator has an independent threshold ...
Power factor correction and harmonic filtering in electrical plants
... computers, printers, diagnostic equipment, etc.) or convert it into another form of energy (e.g. electrical lamps or stoves) or into mechanical output (e.g. electrical motors). To get this, it is often necessary that the load exchanges with the network (with net null consumption) the reactive energy ...
... computers, printers, diagnostic equipment, etc.) or convert it into another form of energy (e.g. electrical lamps or stoves) or into mechanical output (e.g. electrical motors). To get this, it is often necessary that the load exchanges with the network (with net null consumption) the reactive energy ...
Vigirix and Toroids
... They reset automatically when the fault is no longer present. When used in conjunction with an autoreclosing controller, they protect against earth faults caused by insulation failures on: b telephone relays b radio repeaters b special applications. Vigirex relays can be used at all levels of an ins ...
... They reset automatically when the fault is no longer present. When used in conjunction with an autoreclosing controller, they protect against earth faults caused by insulation failures on: b telephone relays b radio repeaters b special applications. Vigirex relays can be used at all levels of an ins ...
24-Bit Capacitance-to-Digital Converter with Temperature Sensor AD7747
... The capacitive input offset can be eliminated using a system offset calibration. The accuracy of the system offset calibration is limited by the offset calibration register LSB size (32 aF) or by converter + system p-p noise during the system capacitive offset calibration, whichever is greater. To m ...
... The capacitive input offset can be eliminated using a system offset calibration. The accuracy of the system offset calibration is limited by the offset calibration register LSB size (32 aF) or by converter + system p-p noise during the system capacitive offset calibration, whichever is greater. To m ...
SIP 05167 Ideal 304 Welder Manual
... This welding equipment for industrial and professional use is in conformity with IEC 60974 International Safety Standard. Hereby we state that we provide one year of guarantee f or this welding equipment since the date of purchase. Please read and understand this instruction manual carefully before ...
... This welding equipment for industrial and professional use is in conformity with IEC 60974 International Safety Standard. Hereby we state that we provide one year of guarantee f or this welding equipment since the date of purchase. Please read and understand this instruction manual carefully before ...
SN74LVC1404 OSCILLATOR DRIVER FOR CRYSTAL OSCILLATOR OR CERAMIC RESONATOR FEATURES
... www.ti.com/sc/package. DCT: The actual top-side marking has three additional characters that designate the year, month, and assembly/test site. DCU: The actual top-side marking has one additional character that designates the assembly/test site. YZP: The actual top-side marking has three preceding c ...
... www.ti.com/sc/package. DCT: The actual top-side marking has three additional characters that designate the year, month, and assembly/test site. DCU: The actual top-side marking has one additional character that designates the assembly/test site. YZP: The actual top-side marking has three preceding c ...
Pre-Configured Systems Datasheet
... Over / Undervoltage Threshold (adjustable from controller) 110VAC Systems................................................................................. 117 to 127VAC / 89 to 105VAC 115VAC Systems..................................................................................122 to 132VAC / 93 t ...
... Over / Undervoltage Threshold (adjustable from controller) 110VAC Systems................................................................................. 117 to 127VAC / 89 to 105VAC 115VAC Systems..................................................................................122 to 132VAC / 93 t ...
Electrical Machines: II. Synchronous Generators
... II. Synchronous Generators Synchronous machines are principally used as alternating current (AC) generators. They supply the electric power used by all sectors of modern societies: industrial, commercial, agricultural, and domestic. Synchronous generators usually operate together (or in parallel ...
... II. Synchronous Generators Synchronous machines are principally used as alternating current (AC) generators. They supply the electric power used by all sectors of modern societies: industrial, commercial, agricultural, and domestic. Synchronous generators usually operate together (or in parallel ...
S6B1713 - ELECTRONIC ASSEMBLY
... The S6B1713 is a driver & controller LSI for graphic dot-matrix liquid crystal display systems. It contains 65 commons and 132 segments driver circuits. This chip is connected directly to a microprocessor, accepts serial or 8-bit parallel display data and stores in an on-chip Display Data RAM of 65 ...
... The S6B1713 is a driver & controller LSI for graphic dot-matrix liquid crystal display systems. It contains 65 commons and 132 segments driver circuits. This chip is connected directly to a microprocessor, accepts serial or 8-bit parallel display data and stores in an on-chip Display Data RAM of 65 ...
SN65HVDA100-Q1 LIN 物理接口(Rev. C)
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
DC Parameters: Input Offset Voltage (VIO)
... The objective of this report is to provide the information necessary for the designer to understand each parameter; what it is, what causes it, and how it is measured, trimmed and specified. Figure 1 presents an ideal op amp together with a table of ideal parameters. The general assumptions listed i ...
... The objective of this report is to provide the information necessary for the designer to understand each parameter; what it is, what causes it, and how it is measured, trimmed and specified. Figure 1 presents an ideal op amp together with a table of ideal parameters. The general assumptions listed i ...
Surge protector

A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".