SBR1A40S3 Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
LTC4006
... The LTC4006 is a synchronous current mode PWM stepdown (buck) switcher battery charger controller. The charge current is programmed by the sense resistor (RSENSE) between the CSP and BAT pins. The final float voltage is internally programmed to 8.4V (LTC4006-6), 12.6V (LTC4006-2) or 16.8V (LTC4006-4 ...
... The LTC4006 is a synchronous current mode PWM stepdown (buck) switcher battery charger controller. The charge current is programmed by the sense resistor (RSENSE) between the CSP and BAT pins. The final float voltage is internally programmed to 8.4V (LTC4006-6), 12.6V (LTC4006-2) or 16.8V (LTC4006-4 ...
Thevenin`s Theorem
... Introduction • Thevenin’s Theorem is a very important and useful theorem. • It is a method for the reduction of a portion of a complex circuit into a simple one. • It reduces the need for repeated solutions of the same sets of equations. ...
... Introduction • Thevenin’s Theorem is a very important and useful theorem. • It is a method for the reduction of a portion of a complex circuit into a simple one. • It reduces the need for repeated solutions of the same sets of equations. ...
Calibration of the Tektronix TDS 2014 Digital Oscilloscope
... 8-bit ADC resolution and four separate input channels. The oscilloscope has ten horizontal divisions along the y-axis and ten vertical divisions along the x-axis. Note that only eight of the ten horizontal divisions are visible on the display. The oscilloscope has a vertical position setting which a ...
... 8-bit ADC resolution and four separate input channels. The oscilloscope has ten horizontal divisions along the y-axis and ten vertical divisions along the x-axis. Note that only eight of the ten horizontal divisions are visible on the display. The oscilloscope has a vertical position setting which a ...
A+ Guide to Managing and Maintaining your PC, 7e Chapter 4 Form
... Figure 4-28 Both surge suppressors alert you when protection is not working. The small surge suppressor is designed to travel with a laptop Courtesy: Course Technology/Cengage Learning A+ Guide to Managing and Maintaining your PC, 7e ...
... Figure 4-28 Both surge suppressors alert you when protection is not working. The small surge suppressor is designed to travel with a laptop Courtesy: Course Technology/Cengage Learning A+ Guide to Managing and Maintaining your PC, 7e ...
MEGOHM BRIDGE
... the control knob set in the CHECK position, the unknown capacitor connected to the UNKNOWN RESISTOR terminals Is placed in parallel with the standard resistor N in the grid circuit of the detector tube. If there is no residual charge in the capacitor, the setting of the ZERO ADIU~ knob will be the s ...
... the control knob set in the CHECK position, the unknown capacitor connected to the UNKNOWN RESISTOR terminals Is placed in parallel with the standard resistor N in the grid circuit of the detector tube. If there is no residual charge in the capacitor, the setting of the ZERO ADIU~ knob will be the s ...
AC versus DC Measurement Methods for Low
... sources simply were not previously available. For the DC reversal method, a current source with reversible polarity is used, and the DUT response is measured with a nanovoltmeter. Lock-in Amplifier Method. Lock-in amplifiers can measure small AC signals, some down to a few nanovolts. With this type ...
... sources simply were not previously available. For the DC reversal method, a current source with reversible polarity is used, and the DUT response is measured with a nanovoltmeter. Lock-in Amplifier Method. Lock-in amplifiers can measure small AC signals, some down to a few nanovolts. With this type ...
basics_of_power_qual.. - IDEAL INDUSTRIES, INC.
... – A Power Analyzer is the tool of choose when the measurement of Power usage are efficiency is desired. ...
... – A Power Analyzer is the tool of choose when the measurement of Power usage are efficiency is desired. ...
DRV632 DirectPath, 2-VRMS Audio Line Driver
... capacitor, typically 1 μF, placed as close as possible to the device VDD lead works best. Placing this decoupling capacitor close to the DRV632 is important for the performance of the amplifier. For filtering lower-frequency noise signals, a 10-μF or greater capacitor placed near the audio power amp ...
... capacitor, typically 1 μF, placed as close as possible to the device VDD lead works best. Placing this decoupling capacitor close to the DRV632 is important for the performance of the amplifier. For filtering lower-frequency noise signals, a 10-μF or greater capacitor placed near the audio power amp ...
WheelockExcederLEDSeriesSpecSheet
... appliances and Series LHN Audible appliances for wall-mount applications with a low-profile design or approved equals. The Series LHS and LST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series LHS and LHN Audibles ...
... appliances and Series LHN Audible appliances for wall-mount applications with a low-profile design or approved equals. The Series LHS and LST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series LHS and LHN Audibles ...
PESD5V0S1UA; PESD12VS1UA 1. Product profile Unidirectional ESD protection for transient voltage
... therefore such inclusion and/or use is at the customer’s own risk. Applications — Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use ...
... therefore such inclusion and/or use is at the customer’s own risk. Applications — Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use ...
BASIC ELECTRICAL MATERIALS AND METHODS 260500
... Emission Standards for Hazardous Air Pollutants. Where asbestos is encountered in a project, the Contractor shall comply with all laws and ordinances pertaining to asbestos handling and abatement, including the latest revision of LAC 33:111, Chapter 25, Subchapter F, Emission Standards for Hazardous ...
... Emission Standards for Hazardous Air Pollutants. Where asbestos is encountered in a project, the Contractor shall comply with all laws and ordinances pertaining to asbestos handling and abatement, including the latest revision of LAC 33:111, Chapter 25, Subchapter F, Emission Standards for Hazardous ...
Infrared Source Series 6x
... The HawkEye IR-6x Series is the perfect solution for an application that requires fast electrical modulation. However, it can also be used in a steady state (dc) mode. In applications where steady state power is used (or if used with electrical modulation but with a duty cycle of greater than 50%), ...
... The HawkEye IR-6x Series is the perfect solution for an application that requires fast electrical modulation. However, it can also be used in a steady state (dc) mode. In applications where steady state power is used (or if used with electrical modulation but with a duty cycle of greater than 50%), ...
TPS40040 数据资料 dataSheet 下载
... The TPS40040 and TPS40041 dc-to-dc controllers are designed to operate from a 2.25-V to 5.5-V input source. To reduce the number of external components, several operating parameters are fixed internally; namely, frequency, soft start time, and short circuit protection (SCP) levels. For example, the ...
... The TPS40040 and TPS40041 dc-to-dc controllers are designed to operate from a 2.25-V to 5.5-V input source. To reduce the number of external components, several operating parameters are fixed internally; namely, frequency, soft start time, and short circuit protection (SCP) levels. For example, the ...
LM2574/LM2574HV SIMPLE SWITCHER 0.5A Step
... replacement for popular three-terminal linear regulators. Because of its high efficiency, the copper traces on the printed-circuit board (PCB) are normally the only heat sinking needed. A standard series of inductors optimized for use with the LM2574 are available from several different manufacturer ...
... replacement for popular three-terminal linear regulators. Because of its high efficiency, the copper traces on the printed-circuit board (PCB) are normally the only heat sinking needed. A standard series of inductors optimized for use with the LM2574 are available from several different manufacturer ...
A6986F - STMicroelectronics
... Switching frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 ...
... Switching frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 ...
74LCX16244 Low Voltage 16-Bit Buffer/Line Driver with 5V Tolerant Inputs and Outputs 7
... Note 4: The Absolute Maximum Ratings are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the Absolute Maximum Ratings. The “Recomme ...
... Note 4: The Absolute Maximum Ratings are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the Absolute Maximum Ratings. The “Recomme ...
Project 14 - Using the Raspberry Pi to measure current
... MCP6002 op-amp: Although we can measure voltage directly using an Analogue to Digital Converter, it’s a bit more tricky measuring current. One way of measuring current is to insert a low value resistor and then measure the voltage across it. We are going to use one of the op-amps from the chip shown ...
... MCP6002 op-amp: Although we can measure voltage directly using an Analogue to Digital Converter, it’s a bit more tricky measuring current. One way of measuring current is to insert a low value resistor and then measure the voltage across it. We are going to use one of the op-amps from the chip shown ...
KNW013-020 - GE Industrial Solutions
... CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal ...
... CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal ...
DRV601 数据资料 dataSheet 下载
... to provide a negative voltage rail. Combining the user provided positive rail and the negative rail generated by the IC, the device operates in what is effectively a split supply mode. The output voltages are now centered at zero volts with the capability to swing to the positive rail or negative ra ...
... to provide a negative voltage rail. Combining the user provided positive rail and the negative rail generated by the IC, the device operates in what is effectively a split supply mode. The output voltages are now centered at zero volts with the capability to swing to the positive rail or negative ra ...
SUPPORT BOOKLET FOR UNIT 1
... be controlled and so some common output devices can now be introduced. Many of these devices are electromagnetic and so the output switching device (transistor or MOSFET) needs to be protected, using a diode, from the large voltage produced when the device is switched off. Relays, themselves, are al ...
... be controlled and so some common output devices can now be introduced. Many of these devices are electromagnetic and so the output switching device (transistor or MOSFET) needs to be protected, using a diode, from the large voltage produced when the device is switched off. Relays, themselves, are al ...
Lab Manual - Lakehead University
... The magnetization curve can be measured with either the shunt circuit configuration as well as with the separately exited circuit configuration. Since we want to investigate the shunt type generator it may appear to be logical to use this circuit for the measurement. However, since the machine needs ...
... The magnetization curve can be measured with either the shunt circuit configuration as well as with the separately exited circuit configuration. Since we want to investigate the shunt type generator it may appear to be logical to use this circuit for the measurement. However, since the machine needs ...
AN11119 Medium power small-signal MOSFETs in DC-to-DC conversion
... In modern electronic designs various supply voltages need to be generated. In most cases power supply provides one or a few different DC voltages. These voltages need to be converted to another voltage for several functional units in the application. Voltage conversion can work in both directions: i ...
... In modern electronic designs various supply voltages need to be generated. In most cases power supply provides one or a few different DC voltages. These voltages need to be converted to another voltage for several functional units in the application. Voltage conversion can work in both directions: i ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".