MAX17502 60V, 1A, Ultra-Small, High-Efficiency, Synchronous Step-Down DC-DC Converter General Description
... The device uses a peak-current-mode control scheme. An internal transconductance error amplifier generates an integrated error voltage. The error voltage sets the duty cycle using a PWM comparator, a high-side current-sense amplifier, and a slope-compensation generator. At each rising edge of the cl ...
... The device uses a peak-current-mode control scheme. An internal transconductance error amplifier generates an integrated error voltage. The error voltage sets the duty cycle using a PWM comparator, a high-side current-sense amplifier, and a slope-compensation generator. At each rising edge of the cl ...
LT6105 - Precision, Rail-to-Rail Input Current Sense Amplier
... For more information on lead free part marking, go to: http://www.linear.com/leadfree/ For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/ ...
... For more information on lead free part marking, go to: http://www.linear.com/leadfree/ For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/ ...
Lecture 11 - University of Arizona
... → Wall “plug-in” transformers (“a.k.a. wall-warts) can supply either an AC or a DC voltage…!?! Dr. Mike Nofziger 2015 Lecture 11 ...
... → Wall “plug-in” transformers (“a.k.a. wall-warts) can supply either an AC or a DC voltage…!?! Dr. Mike Nofziger 2015 Lecture 11 ...
ADUM6200 英文数据手册DataSheet下载
... digital isolators with isoPower®, an integrated, isolated dc-to-dc converter. Based on the Analog Devices, Inc., iCoupler® technology, the dc-to-dc converter provides up to 400 mW of regulated, isolated power at either 5.0 V or 3.3 V from a 5.0 V input supply, or at 3.3 V from a 3.3 V supply at the ...
... digital isolators with isoPower®, an integrated, isolated dc-to-dc converter. Based on the Analog Devices, Inc., iCoupler® technology, the dc-to-dc converter provides up to 400 mW of regulated, isolated power at either 5.0 V or 3.3 V from a 5.0 V input supply, or at 3.3 V from a 3.3 V supply at the ...
Lecture 5
... The Practical Op-Amp Real op-amps differ from the ideal model in various respects. In addition to finite gain, bandwidth, and input impedance, they have other limitations. o Finite open loop gain. o Finite input impedence. o Non-zero output impedence. ...
... The Practical Op-Amp Real op-amps differ from the ideal model in various respects. In addition to finite gain, bandwidth, and input impedance, they have other limitations. o Finite open loop gain. o Finite input impedence. o Non-zero output impedence. ...
A single phase photovoltaic inverter control for grid connected system
... voltages. In single-phase PLL, accurate and fast phase estimation can be obtained by processing a signal in phase with the grid voltage (original signal) and another one which is 90◦ phase shifted from it [19, 20]. The PLL, which generates orthogonal signals by delaying the original signal, is calle ...
... voltages. In single-phase PLL, accurate and fast phase estimation can be obtained by processing a signal in phase with the grid voltage (original signal) and another one which is 90◦ phase shifted from it [19, 20]. The PLL, which generates orthogonal signals by delaying the original signal, is calle ...
wiremaster™ coax bnc - Triplett Test Equipment
... The WireMaster Coax will not work if AC or DC voltage is present. Some coaxial cables have AC or DC voltage on them to operate amplifiers, preamplifiers, LNB’s, etc. The OFF: OVERLOAD / VOLTAGE test position of the Function switch tests the connected cable for the presence of AC or DC voltage. The W ...
... The WireMaster Coax will not work if AC or DC voltage is present. Some coaxial cables have AC or DC voltage on them to operate amplifiers, preamplifiers, LNB’s, etc. The OFF: OVERLOAD / VOLTAGE test position of the Function switch tests the connected cable for the presence of AC or DC voltage. The W ...
60 dB Range (100 nA to 100 µA) ADL5306
... measurement dynamic range in a versatile and easy-to-use form. A single-supply voltage between 3 V and 5.5 V is adequate; dual supplies may optionally be used. Low quiescent current (5 mA typical) permits use in battery-operated applications. IPD, the 100 nA to 100 µA input current applied to the IN ...
... measurement dynamic range in a versatile and easy-to-use form. A single-supply voltage between 3 V and 5.5 V is adequate; dual supplies may optionally be used. Low quiescent current (5 mA typical) permits use in battery-operated applications. IPD, the 100 nA to 100 µA input current applied to the IN ...
AD7538 数据手册DataSheet 下载
... *Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposur ...
... *Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposur ...
Prototype I - GEOCITIES.ws
... layout very carefully to avoid crossing. The effect is similar to a single sided pcb layout. This technique is not suitable for complex circuits, or ones which require many interconnections. ...
... layout very carefully to avoid crossing. The effect is similar to a single sided pcb layout. This technique is not suitable for complex circuits, or ones which require many interconnections. ...
SFH619A - Vishay
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
ADE7762 数据手册DataSheet 下载
... Analog Inputs for the Voltage Channels. These channels are intended for use with voltage transducers and are referenced in this document as voltage channels. These inputs are single-ended voltage inputs with a maximum signal level of ±0.5 V with respect to VN for a specified operation. All inputs ha ...
... Analog Inputs for the Voltage Channels. These channels are intended for use with voltage transducers and are referenced in this document as voltage channels. These inputs are single-ended voltage inputs with a maximum signal level of ±0.5 V with respect to VN for a specified operation. All inputs ha ...
Data Sheet
... of the Hall effect sensor, the circuit will drive the output voltage higher. In contrary, a north magnetic pole will drive the output voltage lower. The variations of voltage level up or down are symmetrical. Because the SOT-23-3 is reversed packaging with TO-92S-3, so the magnetic performance is al ...
... of the Hall effect sensor, the circuit will drive the output voltage higher. In contrary, a north magnetic pole will drive the output voltage lower. The variations of voltage level up or down are symmetrical. Because the SOT-23-3 is reversed packaging with TO-92S-3, so the magnetic performance is al ...
A Low-Noise Self-Calibrating Dynamic Comparator for
... The gate of MC2 is connected to the capacitor CH which is pre-charged to Vb in the initial condition. If the comparator has the offset voltage Voffset (Voffset is positive value in this case) the comparator outputs high, and pulls out the charge of CH according to the current Icp, along with the con ...
... The gate of MC2 is connected to the capacitor CH which is pre-charged to Vb in the initial condition. If the comparator has the offset voltage Voffset (Voffset is positive value in this case) the comparator outputs high, and pulls out the charge of CH according to the current Icp, along with the con ...
Chapter 21 AC Circuits
... Transforms AC voltage UP or DOWN Historical basis for AC Grid your use George Westinghouse (AC) vs Edison (DC) Losses due to resistance in wire and eddy currents in transformer “core” ...
... Transforms AC voltage UP or DOWN Historical basis for AC Grid your use George Westinghouse (AC) vs Edison (DC) Losses due to resistance in wire and eddy currents in transformer “core” ...
LTC3704 - Wide Input Range, No RSENSE Positive-to
... external clock applied to the MODE/SYNC pin and can be locked to a frequency between 100% and 130% of its nominal value. When the MODE/SYNC pin is left open, it is pulled low by an internal 50k resistor and Burst Mode operation is enabled. If this pin is taken above 2V or an external clock is applie ...
... external clock applied to the MODE/SYNC pin and can be locked to a frequency between 100% and 130% of its nominal value. When the MODE/SYNC pin is left open, it is pulled low by an internal 50k resistor and Burst Mode operation is enabled. If this pin is taken above 2V or an external clock is applie ...
LTC6104 - High Voltage, High Side, Bi-Directional Current Sense Amplifier
... dynamic range required. The minimum signal that can be accurately represented by this sense amp is limited by the input offset. As an example, the LTC6104 has a typical input offset of ±85µV. If the minimum current is ±20mA, a sense resistor of 4.25mΩ will set VSENSE to ±85µV. This is the same value ...
... dynamic range required. The minimum signal that can be accurately represented by this sense amp is limited by the input offset. As an example, the LTC6104 has a typical input offset of ±85µV. If the minimum current is ±20mA, a sense resistor of 4.25mΩ will set VSENSE to ±85µV. This is the same value ...
ENGINEERING PHYSICS LAB MANUAL I/II Semester (PHYL17/27)
... In Zener diode both P and N sections are heavily doped but in case of an ordinary diode they are lightly doped. Zener diode has a sharp breakdown voltage and is generally used under reverse bias. Zener diode is used as a voltage regulator in reverse bias whereas ordinary diode is used as a rectifier ...
... In Zener diode both P and N sections are heavily doped but in case of an ordinary diode they are lightly doped. Zener diode has a sharp breakdown voltage and is generally used under reverse bias. Zener diode is used as a voltage regulator in reverse bias whereas ordinary diode is used as a rectifier ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".