• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Class 1000 Meter - E-Mon
Class 1000 Meter - E-Mon

... To ensure a safe installation, the Class 1000 meter requires an external switch mechanism, such as a circuit breaker, be installed on the Class 1000 MAINS input wiring. The switch mechanism must be installed in close proximity to the meter and easily reachable for the operator. This device must also ...
Four-Speed Fan Control Using Simple Remote
Four-Speed Fan Control Using Simple Remote

Film Capacitors – Power Factor Correction
Film Capacitors – Power Factor Correction

... again. This prevents an electric impulse discharge in the application, influences the capacitor’s service life and protects against electric shock. The capacitor must be discharged to 75 V or less within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit b ...
Applications of Circuits
Applications of Circuits

... Other rivers may split into two or more smaller streams as they flow over a waterfall or through a series of rapids. In this case, part of the river follows one path, while other parts of the river follow different paths. No matter how many paths the river takes, however, the total amount of water f ...
AD797* Ultralow Distortion, Ultralow Noise Op Amp
AD797* Ultralow Distortion, Ultralow Noise Op Amp

... The new architecture of the AD797 was developed to overcome inherent limitations in previous amplifier designs. Previous precision amplifiers used three stages to ensure high open-loop gain, Figure 27b, at the expense of additional frequency compensation components. Slew rate and settling performanc ...
resistance
resistance

LT1994 - Low Noise, Low Distortion Fully Differential Input/Output
LT1994 - Low Noise, Low Distortion Fully Differential Input/Output

... temperature range, otherwise specifications are at TA = 25°C. V+ = 3V, V– = 0V, VCM = VOCM = VICM = mid-supply, VSHDN = OPEN, RI = RF = 499Ω, RL = 800Ω to a mid-supply voltage (See Figure 1) unless otherwise noted. VS is defined (V+ – V–). VOUTCM is defined as (VOUT+ + VOUT–)/2. VICM is defined as (VIN+ ...
IF 1720 Revision 2
IF 1720 Revision 2

... screws. All components in the fixture are prewired so only line in, neutral, and ground need to be connected in the fixture to the terminals per the wiring diagrams using methods that comply with all applicable codes. Use 75°C min and 600 V min supply cord with outer sheath diameter in accordance wi ...
LinCMOS Precision Quad Operational
LinCMOS Precision Quad Operational

2 Static Characteristics II
2 Static Characteristics II

Chapter28
Chapter28

lecture1423723848
lecture1423723848

750 VDC TRACTION SYSTEM
750 VDC TRACTION SYSTEM

rail mounted power network meter n43 n43 type user`s manual
rail mounted power network meter n43 n43 type user`s manual

... Entry into monitoring of maximum and minimum values mode occurs when pressing at the same time the buttons and for at least 3 seconds. Erasing maximum and minimum values is done by pressing the button while monitoring their value.Alarms are active if they were allocated. Note that the alarms do not ...
MAX16930/MAX16931 2MHz, 36V, Dual Buck with Preboost and 20µA Quiescent Current General Description
MAX16930/MAX16931 2MHz, 36V, Dual Buck with Preboost and 20µA Quiescent Current General Description

... preboost controller. They operate with an input voltage supply from 2V to 42V with preboost active and can operate in drop-out condition by running at 95% duty cycle. The devices are intended for applications with mid- to high-power requirements that operate at a wide input voltage range such as dur ...
IR3550 - Infineon
IR3550 - Infineon

... 1. Guaranteed by design but not tested in production 2. VIN=12V, VOUT=1.2V, ƒSW = 300kHz, L=210nH (0.2mΩ), VCC=6.8V, CIN=47uF x 4, COUT =470uF x3, 400LFM airflow, no heat sink, 25°C ambient temperature, and 8-layer PCB of 3.7” (L) x 2.6” (W). PWM controller loss and inductor loss are not included. 3 ...
A Time-Based Energy-Efficient Analog-to-Digital Converter
A Time-Based Energy-Efficient Analog-to-Digital Converter

... At the end of the MSB phase, the comparator requires a finite amount of time to signal that the voltages on and are will be larger than its ideal value, which equal. As a result, translates into a smaller through (2). Naturally, the voltage charges on , as defined in (3), will be smaller. When up to ...
J.M. Rivas, Y. Han, O. Leitermann, A.D. Sagneri, and D.J. Perreault, “A High-Frequency Resonant Inverter Topology with Low Voltage Stress,” 2007 IEEE Power Electronics Specialists Conference, pp. 2705 – 2717
J.M. Rivas, Y. Han, O. Leitermann, A.D. Sagneri, and D.J. Perreault, “A High-Frequency Resonant Inverter Topology with Low Voltage Stress,” 2007 IEEE Power Electronics Specialists Conference, pp. 2705 – 2717

... inverter, which we term the Φ2 inverter, that is well suited to operation at very high frequencies and to rapid on/off control. Features of this inverter topology include low semiconductor voltage stress, small passive energy storage requirements, fast dynamic response, and good design flexibility. T ...
LTC3404 - 1.4MHz High Efficiency Monolithic Synchronous Step-Down Regulator
LTC3404 - 1.4MHz High Efficiency Monolithic Synchronous Step-Down Regulator

... frequency ripple from interfering with audio circuitry. The internal synchronous switch increases efficiency and eliminates the need for an external Schottky diode. Low output voltages are easily supported with the 0.8V feedback reference voltage. The LTC3404 is available in a ...
MAX1997/MAX1998 Quintuple/Triple-Output TFT LCD Power Supplies with Fault Protection and VCOM Buffer
MAX1997/MAX1998 Quintuple/Triple-Output TFT LCD Power Supplies with Fault Protection and VCOM Buffer

... MAX1998 can operate from input supplies of 2.7V to 5.5V and feature multiple levels of protection circuitry, making them complete power-supply systems for displays. The main DC-DC converter provides the regulated supply voltage for the display’s source-driver ICs. The converter is a high-frequency ( ...
kewtech - Test It Now
kewtech - Test It Now

... Kewtech will not accept liability for any damage or injury caused by misuse or non-compliance with instructions or safety procedures. 1.2 This instrument is only intended for single phase operation, 230V AC+10%-15% phase to earth or phase to neutral operation. Although fully protected (no bangs), it ...
K. Long, A.Z. Kattamis, I.-C. Cheng, H. Gleskova, S. Wagner, J.C. Sturm, M. Stevenson, G. Yu, and M. O’Regan, “Active Matrix Amorphous-Silicon TFT Arrays at 180 oC on Clear Plastic and Glass Substrates for Organic Light-Emitting Displays,” IEEE Trans. Elec. Dev. TED-53, pp. 1789-1796, (2006).
K. Long, A.Z. Kattamis, I.-C. Cheng, H. Gleskova, S. Wagner, J.C. Sturm, M. Stevenson, G. Yu, and M. O’Regan, “Active Matrix Amorphous-Silicon TFT Arrays at 180 oC on Clear Plastic and Glass Substrates for Organic Light-Emitting Displays,” IEEE Trans. Elec. Dev. TED-53, pp. 1789-1796, (2006).

... of 16. At this point, the pixel current would be 2 µA. A 3 in × 3 in test sample with several small AMOLED arrays and test structures in the center 1 in × 1 in area was fabricated. The outside area was for interconnecting lines, for external connection for driving electronics and environmental seali ...
Design of Power-Rail ESD Clamp Circuit with Adjustable Holding
Design of Power-Rail ESD Clamp Circuit with Adjustable Holding

Tampere University of Applied Sciences, Master of engineering
Tampere University of Applied Sciences, Master of engineering

... working of the model and explain which input values we used. We will run the simulation to show what the outputs are. In the fifth part of my thesis I will make estimations of the losses of the electrical part of the ASWEC-machine. My estimations include the generator losses in the windings, the los ...
1 AP240E Data Analysis Program Bulletin CW-E
1 AP240E Data Analysis Program Bulletin CW-E

... Simultaneous measurement of instantaneous value, electric energy, demand, harmonics and voltage fluctuation. Simultaneous measurement of loads in 4 systems of up to 1P2W Simultaneous measurement of loads in 2 systems of up to 1P/3P3W Data saving interval can be set from 1 waveform (for instantane ...
< 1 ... 237 238 239 240 241 242 243 244 245 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report