• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
medium-voltage switchgear
medium-voltage switchgear

MAX1365/MAX1367 Stand-Alone, 4.5-/3.5
MAX1365/MAX1367 Stand-Alone, 4.5-/3.5

... CS_DAC...............................................-0.3V to (DVDD + 0.3V) NEGV .......................................................-2.6V to (AVDD + 0.3V) LED_EN....................................................-0.3V to (DVDD + 0.3V) SET......................................................... ...
part 3 execution - Schneider Electric
part 3 execution - Schneider Electric

... the flaps without causing permanent deformation. Provisions shall be made so that switch gear lineups can be extended on either end. 3. The sections are divided by metal barriers into the following separate compartments: (a.) Circuit breaker(s), instrument, main bus, auxiliary device and cable. Each ...
Document
Document

212b202
212b202

... trick question, my physics professor would never do such thing (do not pick this answer, it is for humor purposes only!). A physics professor with a body resistance of 10k accidentally grips the terminals of a 10kV power supply which has an internal resistance of 10M. If a potentially lethal shock ...
pm700 installation manual
pm700 installation manual

... Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions. NEVER work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all sources of electric power. Assume that al ...
TPA3001D1 数据资料 dataSheet 下载
TPA3001D1 数据资料 dataSheet 下载

... Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. PowerPAD is a trademark of Texas Instruments. All other trademarks are the ...
:  II ELECTRONIC  SCIENCE
: II ELECTRONIC SCIENCE

FAN3240 / FAN3241 Smart Dual-Coil Relay Drivers FAN3240 / FAN32
FAN3240 / FAN3241 Smart Dual-Coil Relay Drivers FAN3240 / FAN32

... outputs are disabled and exhibit high impedance regardless of the status of the input and enable pins. The device becomes fully functional when the VS voltage exceeds the UVLO turn-on threshold and stays operational until the VS voltage falls below the UVLO turn-off threshold. The nominal UVLO hyste ...
User Manual - datakom.com.tr
User Manual - datakom.com.tr

... The unit is a display and control module used in manual synchronization and protection panels. It monitors the voltage and frequency of 2 independent power networks and shows the measured values on its 3-digit digital display. The 24 led circular synchroscope indicates the true instantenous phase an ...
EES005 Electrical Protection and Earthing Guideline
EES005 Electrical Protection and Earthing Guideline

... conductors insulated from one another and which is designed to afford relative motion between its terminal points while it is energised. Main earth leakage. Earth leakage protection that is expected to operate first under fault conditions – the earth leakage protection generally installed to protect ...
AD9708 数据手册DataSheet 下载
AD9708 数据手册DataSheet 下载

... The AD9708 is the 8-bit resolution member of the TxDAC series of high performance, low power CMOS digital-to-analog converters (DACs). The TxDAC family, which consists of pin compatible 8-, 10-, 12-, and 14-bit DACs, was specifically optimized for the transmit signal path of communication systems. A ...
BDTIC www.BDTIC.com/infineon Ballast Design for 54W T5 Fluorescent Lamp
BDTIC www.BDTIC.com/infineon Ballast Design for 54W T5 Fluorescent Lamp

... development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microsoft Corporation. FlexRay™ is licensed by FlexRay Consortium. HYPERTERMINAL™ of Hilgraeve Inco ...
P84155
P84155

... NOTE: The Code 3 Horn and Code 3 Tone (set on HIGH dBA) incorporate the temporal pattern specified by ANSI/NFPA for standard emergency evacuation signaling. They should be used only for fire evacuation signaling and not for any other purpose. The Horn and Bell Tones can be used on coded systems with ...
8. Resistance - The Physics Teacher
8. Resistance - The Physics Teacher

... (iv) Describe an experiment to investigate if a substance is a conductor or an insulator. Apparatus: circuit to show power source, ammeter/ bulb, leads, Procedure: connect the circuit and place item between contacts Observation: If the bulb lights then the item is a conductor; if the bulb does not l ...
TUMBLER POWER SWITCHES
TUMBLER POWER SWITCHES

MAX1777/MAX1977/MAX1999 High-Efficiency, Quad Output, Main Power- Supply Controllers for Notebook Computers General Description
MAX1777/MAX1977/MAX1999 High-Efficiency, Quad Output, Main Power- Supply Controllers for Notebook Computers General Description

... 28-Pin QSOP (derate 10.8mW/°C above +70°C).........860mW Operating Temperature Range ...........................-40°C to +85°C Junction Temperature ......................................................+150°C Storage Temperature Range .............................-65°C to +150°C Lead Temperature (so ...
THE NATURE OF CAPACITANCE
THE NATURE OF CAPACITANCE

“How to Implement ICP Using ELAN EM78PXXX General Purpose OTP MCUs”
“How to Implement ICP Using ELAN EM78PXXX General Purpose OTP MCUs”

... application circuit functions normally, the resistor values must be chosen such that the 2N3904 is switched off during normal operation of the circuit. When designing your application, you should also consider the ON state resistance of the CD4066 switch, which can depend on the supply voltage. Note ...
Datasheet - Intersil
Datasheet - Intersil

... http://www.intersil.com/pbfree/Pb-FreeReflow.asp *Pb-free PDIPs can be used for through hole wave solder processing only. They are not intended for use in Reflow solder processing applications. ...
PowerLogic™ DM6000 Series Digital Meters Quick Start Guide
PowerLogic™ DM6000 Series Digital Meters Quick Start Guide

p – n junction
p – n junction

Protection against electric shocks
Protection against electric shocks

... Specified maximum disconnection time The tripping times of RCDs are generally lower than those required in the majority of national standards; this feature facilitates their use and allows the adoption of an effective discriminative protection. The IEC 60364-4-41 specifies the maximum operating time ...
TPS386596 Quad Reset Supervisor With Manual Reset Input (Rev. A)
TPS386596 Quad Reset Supervisor With Manual Reset Input (Rev. A)

... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
a High Performance 4/8 Channel Fault-Protected Analog Multiplexers ADG438F/ADG439F*
a High Performance 4/8 Channel Fault-Protected Analog Multiplexers ADG438F/ADG439F*

... comprising four differential channels. These multiplexers provide fault protection. Using a series n-channel, p-channel, nchannel MOSFET structure, both device and signal source protection is provided in the event of an overvoltage or power loss. The multiplexer can withstand continuous overvoltage ...
< 1 ... 181 182 183 184 185 186 187 188 189 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report