• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CURRENT Electricity
CURRENT Electricity

... Closed circuit : the circuit is continuous; the switch is “on” and the current is flowing Open circuit : there is a break in the circuit; no current can flow (switch is “off”) ...
Warnings, information and notes regarding designation of the product
Warnings, information and notes regarding designation of the product

... By qualified personnel only. ISKRA Company assumes no responsibility in connection with installation This booklet contains instructions for installation and use of measuring instrument. Installation and use of a device also includes handling with dangerous currents and voltages therefore should be i ...
DC1902B – LT4320 Ideal Diode Bridge Controller
DC1902B – LT4320 Ideal Diode Bridge Controller

... Linear Technology Corporation (LTC) provides the enclosed product(s) under the following AS IS conditions: This demonstration board (DEMO BOARD) kit being sold or provided by Linear Technology is intended for use for ENGINEERING DEVELOPMENT OR EVALUATION PURPOSES ONLY and is not provided by LTC for ...
H91-23 Inverter Converter
H91-23 Inverter Converter

... The H91-23 Inverter Converter is used to convert any DC voltage signal of +/-3.40, to +/-30 Volts to either a +/-5, +/-12, or +/-24 volt signal. In addition, the H91-23 includes selectable debounce time constants of 1 millisecond, 10 milliseconds and 25 milliseconds for converting signals generated ...
Datasheet - Pump Centre
Datasheet - Pump Centre

... Nominal capacity (Ah) Cut-off voltage (V) Cell/Monoblock Configuration Serial String Configurations Number of cells Parallel String Configurations Number of serial strings Number of cells per string Battery Characteristics Voltage (V) Nominal Capacity (Ah) Condition Monitoring System (P) Required (Y ...
Transverter Interface Unit
Transverter Interface Unit

... It is best to start with the control circuitry. Solder in the components, leaving TR2 and TR3 until last. These are static sensitive devices and should not be left out of their protective foam for long periods. The 2.2W protection resistors are wired off board, between the PCB and output connection ...
The Do`s and Don`ts of Using MOS-Gated Transistors
The Do`s and Don`ts of Using MOS-Gated Transistors

... violated. IGBTs, however, do not have an avalanche rating, and a clamping device should be connected, physically as close as possible to the drain and source terminals, as shown in Figure 5. A conventional zener diode, or a "transorb" clamping device, are satisfactory for this purpose. An alternativ ...
View District Syllabus - Tarrant County College
View District Syllabus - Tarrant County College

... TARRANT COUNTY COLLEGE DISTRICT MASTER SYLLABUS COURSE DESCRIPTION Principles of electricity as required by HVAC, including proper use of test equipment, electrical circuits, and component theory and operation. Co-requisite: TECM-1303 COURSE TYPE Technical COURSE GOALS AND LEARNING OUTCOMES End-of-C ...
DM5426/DM7426 Quad 2-Input NAND Gates with High Voltage
DM5426/DM7426 Quad 2-Input NAND Gates with High Voltage

... DM5426/DM7426 Quad 2-Input NAND Gates with High Voltage Open-Collector Outputs ...
resistive SWR bridge final copy
resistive SWR bridge final copy

... as the input RF voltage. In this instance the peak DC voltage at point Z will be almost half the peak RF voltage applied (RF volts input - RF Volts/2 [point X]). Alternatively, if the load impedance is now made very low (say 1 Ohm), RF volts at point Y is almost zero so the peak detector will again ...
ppt
ppt

... As process technology improves, more devices will be integrated onto a chip, designs will grow more ...
Chapter 22 notes
Chapter 22 notes

Motion in one and two dimensions
Motion in one and two dimensions

... supply system; and describe and explain the operation of the system and its components, and the effects of test equipment on the system. To achieve this outcome the student will draw on knowledge and skills outlined in detailed study 3.3. Key knowledge and skills To achieve this outcome the student ...
Data sheet Harley Benton
Data sheet Harley Benton

... For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed and are not in the reach of babies and young children. Choking hazard! Do not just dispose these m ...
PDF FILE - Emergency Lighting
PDF FILE - Emergency Lighting

... CHARGING METHODS CYCLIC USE: Maximum Initial Charge Current: 1.125A Charging Voltage: 7.2V-7.35V Charge should be switched to float mode or disconnected when current drops to 70mA STANDBY USE: Maximum Initial Charge Current: 1.125A Charge Voltage: 6.75V-6.9V ...
2STR1230
2STR1230

... Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ...
SCCR Rated BSP UL Series (Type 2)
SCCR Rated BSP UL Series (Type 2)

418 Traffic Flyer - Struthers-Dunn
418 Traffic Flyer - Struthers-Dunn

... The 418 Series Relay is designed as a direct “drop-in” replacement for existing mercury displacement relays. The 418 Series is a single pole hybrid relay which features an LED indicator to verify circuit power which simplifies trouble-shooting by field maintenance personnel. ...
4. Compensation Method
4. Compensation Method

... where RAB is the resistance of potentiometer and U AB is voltage on potentiometer. By moving the slide C along the wire, voltage U AC can be changed from zero to U AB . Relying on the formulas (5) and (2) we get U AC = I ⋅ R AC = φ A − φ B . Connecting the studied galvanic element ε to the points A ...
DifferentialLines
DifferentialLines

Datasheet proStop - Non Solenoid Switch Body - Standard
Datasheet proStop - Non Solenoid Switch Body - Standard

... Depressing the plunger breaks the dual safety circuits to shut down the motive power to the machine and makes the monitoring circuit. • Ideal for quick access to machines with no or short run-down cycles • LED indicators for status identification • To be used with safety relay and/or safety PLC cont ...
Here the input voltage to the circuit is given by v(t) - Rose
Here the input voltage to the circuit is given by v(t) - Rose

... Here the input voltage to the circuit is given by v(t). The capacitor is fully discharged at time 0. We want to find the ideal op amp’s output voltage. For ideal op amp, the voltages of the input terminals are equal. The inverted terminal is grounded, so it’s at 0 V. This means that the non-invertin ...
Experiment 3: Power Supply Design Project Design Team A
Experiment 3: Power Supply Design Project Design Team A

... The full-wave rectifier inverts the negative portion of the sinusoidal so that the output is generated during both halve of the sine wave, seen in figure 1. Our rectifier circuit was designed with two diodes on the positive and negative terminals of the transformer respectively. This allowed for the ...
Series Circuits
Series Circuits

... 2. Make observations about the bulbs brightness. 3. Add a 2nd bulb into the circuit. Make sure you have only one path between battery terminals. Use only one battery. 4. Make observations about the brightness of each bulb. Q1: What quantity have you changed by adding another bulb to the circuit? Q2: ...
Sizing a rectifier-based power supply
Sizing a rectifier-based power supply

... value. This is where the capacitor, C, and the LM78XX voltage regulator of Figure 1 become important. A typical voltage regulator requires that the voltage on the input pin maintain a certain margin above the regulated output voltage. This is typically in the range of 2.5 to 3 V and for the LM7805, ...
< 1 ... 1400 1401 1402 1403 1404 1405 1406 1407 1408 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".