• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Power-Factor Controller (PFC) TDA 4862 IC for High Power Factor
Power-Factor Controller (PFC) TDA 4862 IC for High Power Factor

... voltage over several line cycles. Typically the bandwidth is set below 20 Hz. ln order to keep the output voltage constant the voltage amplifier output is connected to the multiplier input for regulation. Overvoltage Regulator Fast changes of the output voltage can’t be regulated by the integrator f ...
Word
Word

... Functional Specification for D-73P Disconnect Switches ...
a two stage isolated bidirectional dc/dc convertor for pv
a two stage isolated bidirectional dc/dc convertor for pv

Full-text
Full-text

Load balancing by SVC Light
Load balancing by SVC Light

... the same origin, a relatively large inductance separates the intermediate level from the power grid. The impedance up to the grid makes it simple to trap harmonic currents in passive filters, as the filter circuit efficiently becomes a low impedance path compared with the power transformer and the n ...
Novel Dielectrics and Advanced Electrical Insulation Technology
Novel Dielectrics and Advanced Electrical Insulation Technology

... Everything electrical has to be insulated to prevent electrical breakdown in circuits / systems, thus the use of dielectric materials Insulators (dielectric materials) can be solid, liquid, gaseous form, in which valance electrons “strongly” attached to the atom under “normal” electrical stress (pro ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.1, pp. 1743-1748
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.1, pp. 1743-1748

... phase DVR is adopted for each phase instead of using three phase DVR to compensate unbalanced sags/swells. Programmable voltage source is used to create sags/swells with required magnitude and time period. In this paper voltage type Impedance Source Inverter (ISI) is employed to compensate deep volt ...
Electric Current Study Guide
Electric Current Study Guide

... b. The location on an electric circuit where the charge possesses the greatest amount of electric potential energy is the + terminal of the battery. c. Charge is supplied with energy in the internal circuit and the energy is transformed into other forms in the external circuit. d. If a unit of charg ...
Bus Voltage Degradation - Trans-Coil
Bus Voltage Degradation - Trans-Coil

... Passive harmonic filters are commonly applied to the input of six pulse rectifier input VFDs as an economical means to meet IEEE-519-2014 source harmonic requirements. Passive harmonic filters primarily consist of a series line reactor and a shunt LC tuned circuit. The shunt circuit is tuned near th ...
Definitions of voltage unbalance
Definitions of voltage unbalance

... Vbc = 480 ∠ 221.4°, and Vca = 384∠124.2 ° are applied to an induction machine. The average value of the magnitudes will be (576 + 480 + 384)/3 = 480 V and the maximum deviation from average value is (576 - 480) = 96 V. Therefore, the NEMA definition of % voltage unbalance will be 100 ⭈ (96/480) = 20 ...
ALS-421 Analog Output Board Nuclear Automation Background
ALS-421 Analog Output Board Nuclear Automation Background

... The ALS-421 is designed for autonomous operation, allowing the system level design to maintain the overall integrity of the application, whether a fault occurs within the individual board or at the system level. A failure in one channel does not impact the other channels. ...
CSE241 VLSI Digital Circuits Winter 2003 Lecture 01
CSE241 VLSI Digital Circuits Winter 2003 Lecture 01

Unit 4 Electricity and Magnetism
Unit 4 Electricity and Magnetism

... electromagnetism - interaction between electricity and magnetism electromagnet - coil with a soft iron core that acts as a magnet while an electric current is in the coil Current Electricity- the flow of electricity in current electricity has electrical pressure or voltage. Electric charges flow fro ...
In this paper, an LLC resonant converter design
In this paper, an LLC resonant converter design

... or constant power load applications, the battery voltage and current are nonlinear and vary with the charging profiles, making the optimal design of battery charger more difficult and complicated. Based on the characteristics of the battery charging profiles, a new time-weighted average efficiency ( ...
DM-5 Power Quality Analyzer
DM-5 Power Quality Analyzer

... transfer data remotely by connecting the DM-5 to compatible Bluetooth® enabled Windows® and Android® devices. This provides added convenience and safety, allowing for easy testing modifications even when the main unit is in difficult to access locations. ...
Circuits - Fulton County Schools
Circuits - Fulton County Schools

Selecting a Littelfuse Varistor
Selecting a Littelfuse Varistor

... Consider the maximum continuous voltage that will be applied to the varistor including any high line conditions (i.e., 110% or more of nominal voltage). Ratings are given for continuous sinusoidal AC and DC voltages. If a nonsinusoidal waveform is applied, the recurrent peak voltage should be limite ...
50 ppm/C Max, 50 uA, CMOS Voltage Reference
50 ppm/C Max, 50 uA, CMOS Voltage Reference

... The REF30xx family of references features an extremely low dropout voltage. With the exception of the REF3012, which has a minimum supply requirement of 1.8 V, the REF30xx can be operated with a supply of only 1 mV above the output voltage in an unloaded condition. For loaded conditions, a typical d ...
A Direct Voltage Unbalance Compensation Strategy for
A Direct Voltage Unbalance Compensation Strategy for

... wind turbines, photovoltaic systems and micro-turbines, have gain a great increasing interest since they are economic and environment friendly. In general, power electronic converters are used as interfaces between DERs and the grid [1], such that electrical power with good quality and high reliabil ...
STU6N90K5 Datasheet - STMicroelectronics
STU6N90K5 Datasheet - STMicroelectronics

... STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing or ...
doc - Cornerstone Robotics
doc - Cornerstone Robotics

...  Pin 1: Ground, The 0V connection to the power supply. All voltages are measured with respect to this terminal.  Pin 2: Trigger, The negative input into inverting comparator 2. A negative pulse on this pin "sets" the internal flip-flop. When the trigger voltage drops from above to below 1/3 VCC, t ...
Electrical Engineering Semester - VI
Electrical Engineering Semester - VI

... design problem. Mechanical design of transmission line: Considerations, loading on conductors, span, sag and tension clearance, stringing, problems.) Transmission line tower design: Location of tower, earth wires, reduction of tower footing resistance, design of tower, examples. EHV transmission lin ...
Cardinal Tremolo V2
Cardinal Tremolo V2

... output if you are omitting both C2 and C6 or if your FETs are lower gain than the 2N5457. Bias1 trim sets Q1. Bias2 sets Q2 and Q3. ➤ Important: Q2 and Q3 must be MATCHED so that they can be trimmed to the same voltage for correct harmonics and amplification. You want to find two 2N5457s that will b ...
ReliaGear ND Descriptive Bulletin
ReliaGear ND Descriptive Bulletin

... interlocking. Separate hard-wiring is not needed for the horizontal communication between the switchgear cubicles. Relion relays for feeder protection offer an optional cable fault detection function that can detect extremely short duration underground faults. These faults are typically undetectable ...
Aalborg Universitet A Direct Voltage Unbalance Compensation Strategy for Islanded Microgrids
Aalborg Universitet A Direct Voltage Unbalance Compensation Strategy for Islanded Microgrids

... wind turbines, photovoltaic systems and micro-turbines, have gain a great increasing interest since they are economic and environment friendly. In general, power electronic converters are used as interfaces between DERs and the grid [1], such that electrical power with good quality and high reliabil ...
< 1 ... 926 927 928 929 930 931 932 933 934 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report