MAX31913 Industrial, Octal, Digital Input Translator/Serializer General Description
... conditions, and serializes the 24V digital output of sensors and switches used in industrial, process, and building automation to 5V CMOS-compatible signals required by microcontrollers. It provides the front-end interface circuit of a programmable logic controller (PLC) digital input module. The de ...
... conditions, and serializes the 24V digital output of sensors and switches used in industrial, process, and building automation to 5V CMOS-compatible signals required by microcontrollers. It provides the front-end interface circuit of a programmable logic controller (PLC) digital input module. The de ...
pdf file
... with the boundary between depleted and undepleted silicon and its upper side aligned with the metallurgical boundary of the p − n junction near the surface of the device, then the Gauss’s law for the volume inside the box can be written as follows. Assuming that such box is three dimensional and occ ...
... with the boundary between depleted and undepleted silicon and its upper side aligned with the metallurgical boundary of the p − n junction near the surface of the device, then the Gauss’s law for the volume inside the box can be written as follows. Assuming that such box is three dimensional and occ ...
A New Topology of Single-Phase Nine
... Presently multilevel inverters have become more attractive for researchers due to their advantages over conventional threelevel Pulse width-modulated (PWM) inverters. MLI has two main advantages compared with the conventional H-bridge inverters [2]-[4], the higher voltage capability and the reduced ...
... Presently multilevel inverters have become more attractive for researchers due to their advantages over conventional threelevel Pulse width-modulated (PWM) inverters. MLI has two main advantages compared with the conventional H-bridge inverters [2]-[4], the higher voltage capability and the reduced ...
operating instruction
... refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter. Caution: risk of electric shock This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. This CAUTION symbol indicates a poten ...
... refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter. Caution: risk of electric shock This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. This CAUTION symbol indicates a poten ...
Low Power DC/DC Boost Converter in SOT-23
... All inductive step-up converters exhibit high inrush current during start-up if no special precaution is made. This can cause voltage drops at the input rail during start up and may result in an unwanted or early system shut down. ...
... All inductive step-up converters exhibit high inrush current during start-up if no special precaution is made. This can cause voltage drops at the input rail during start up and may result in an unwanted or early system shut down. ...
NCL30051LEDGEVB 35-50 Volt, Up to 1.5 Amp, Offline Power Factor
... junction temperature and the typical load power would be ~53 W which is over 100 lm/W. This application note also focuses on various options for dimming including PWM, analog and bi−level dimming. Intelligent dimming takes full advantage of the instant turn−on characteristics of LEDs and combines it ...
... junction temperature and the typical load power would be ~53 W which is over 100 lm/W. This application note also focuses on various options for dimming including PWM, analog and bi−level dimming. Intelligent dimming takes full advantage of the instant turn−on characteristics of LEDs and combines it ...
DESIGN ON MIXED-VOLTAGE-TOLERANT I~slash~O INTERFACE
... decreased to reduce power consumption [1]. For example, the VDD is decreased to 1.2V in the typical 0.13-µm CMOS process. However, some peripheral components or other ICs are still operated with the higher voltage levels such as 2.5V, 3.3V, or 5V for different system specifications [2]. In other wor ...
... decreased to reduce power consumption [1]. For example, the VDD is decreased to 1.2V in the typical 0.13-µm CMOS process. However, some peripheral components or other ICs are still operated with the higher voltage levels such as 2.5V, 3.3V, or 5V for different system specifications [2]. In other wor ...
90% Efficient Synchronous Boost Converter With 600
... The TPS6107x devices provide a power supply solution for products powered by either a one-cell, two-cell, or three-cell alkaline, NiCd or NiMH, or one-cell Li-ion or Li-polymer battery. Output currents can go as high as 75 mA while using a single-cell alkaline, and discharge it down to 0.9 V. It can ...
... The TPS6107x devices provide a power supply solution for products powered by either a one-cell, two-cell, or three-cell alkaline, NiCd or NiMH, or one-cell Li-ion or Li-polymer battery. Output currents can go as high as 75 mA while using a single-cell alkaline, and discharge it down to 0.9 V. It can ...
SA50-28-3R3S Datasheet
... The Power Supply’s internal clock may be synchronized to an external signal. For enhanced system configuration flexibility and noise immunity, the sync input circuit is magnetically isolated from all other circuits and chassis. The interface is shown below. The circuit operates from the rising (lead ...
... The Power Supply’s internal clock may be synchronized to an external signal. For enhanced system configuration flexibility and noise immunity, the sync input circuit is magnetically isolated from all other circuits and chassis. The interface is shown below. The circuit operates from the rising (lead ...
electrical diagrams
... (d) Arrowheads can be drawn closed or open, except when showing a "protective gap" (a gap placed between line parts and the ground which limits the maximum over-voltage that may occur.) ...
... (d) Arrowheads can be drawn closed or open, except when showing a "protective gap" (a gap placed between line parts and the ground which limits the maximum over-voltage that may occur.) ...
Capacitive element based sensor
... Due to an alternating voltage input to the primary coil, alternating electromagnetic forces (emfs) are generated in secondary coils. When the magnetic core is centrally placed with its half portion in each of the secondary coil regions then the resultant voltage is zero. If the core is displaced fro ...
... Due to an alternating voltage input to the primary coil, alternating electromagnetic forces (emfs) are generated in secondary coils. When the magnetic core is centrally placed with its half portion in each of the secondary coil regions then the resultant voltage is zero. If the core is displaced fro ...
Application Note Closed Loop Control Maximizes MAPM-030400-010C00 and MAPM-030400-060C00 Module Performance
... coupler, and the reflected power port can be used for VSWR protection as discussed in Section VII. The RF detector must have a response that is directly proportional to the RF waveform. Furthermore, for distortion-free AM, the detector must have a linear response. A linearly responding detector, suc ...
... coupler, and the reflected power port can be used for VSWR protection as discussed in Section VII. The RF detector must have a response that is directly proportional to the RF waveform. Furthermore, for distortion-free AM, the detector must have a linear response. A linearly responding detector, suc ...
Guidelines for Modernizing Existing Electrical
... Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks ...
... Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks ...
proper selection of control circuit transformers
... compliance with these requirements by placing a CE mark on the product. The EN61558-2 standard replaces the previous EN60742 standard. The EN60742 standard expired December 31, 2003. However, some manufacturers still carry the CE mark based on the expired EN60742 standard. Thus, care should be taken ...
... compliance with these requirements by placing a CE mark on the product. The EN61558-2 standard replaces the previous EN60742 standard. The EN60742 standard expired December 31, 2003. However, some manufacturers still carry the CE mark based on the expired EN60742 standard. Thus, care should be taken ...
4831.2 2-position electric actuators with Ball valves XBZ 3
... close the main shut-off valve in the pipework, release pressure in the pipes and allow them to cool down completely. If necessary, disconnect electrical connections from terminals. ...
... close the main shut-off valve in the pipework, release pressure in the pipes and allow them to cool down completely. If necessary, disconnect electrical connections from terminals. ...
MegaPulse 1.2x50-8x20-12±2ohmBack.ai
... A Compliance West Surge Tester. That means it outputs a guaranteed waveform but won’t break the bank. We don’t believe in frills that never get used but we do believe in providing a user-friendly, reliable tester that outputs the waveform it is supposed to, time after time. The MegaPulse 1.2x50/8x20 ...
... A Compliance West Surge Tester. That means it outputs a guaranteed waveform but won’t break the bank. We don’t believe in frills that never get used but we do believe in providing a user-friendly, reliable tester that outputs the waveform it is supposed to, time after time. The MegaPulse 1.2x50/8x20 ...
Tips For Fusor Builders
... mysterious phenomenon. This is a working hot-fusion technlogy, which has been proven to work in one lab after another, for decades. It is based on straightforward classical physics. The key concept is Inertial Electrostatic Confinement (IEC) using either direct Ion Acceleration (IXL) or indirect ion ...
... mysterious phenomenon. This is a working hot-fusion technlogy, which has been proven to work in one lab after another, for decades. It is based on straightforward classical physics. The key concept is Inertial Electrostatic Confinement (IEC) using either direct Ion Acceleration (IXL) or indirect ion ...
INA138-Q1, INA168-Q1
... Input common-mode and power-supply voltages are independent, and range from 2.7 V to 36 V for the INA138-Q1, and 2.7 V to 60 V for the INA168-Q1. Quiescent current is only 25 μA, which permits connecting the power supply to either side of the current-measurement shunt with minimal error. The device ...
... Input common-mode and power-supply voltages are independent, and range from 2.7 V to 36 V for the INA138-Q1, and 2.7 V to 60 V for the INA168-Q1. Quiescent current is only 25 μA, which permits connecting the power supply to either side of the current-measurement shunt with minimal error. The device ...
14PE8 Current-Fed Switched Inverter IEEE Nag, S.S. Mishra, S
... Inverter systems with step-up transformers having a high turn’s ratio are generally bulky and noisy. Therefore, the alternate option is to go for a transformer- less design. The maximum gain of conventional boost converter is achieved at duty ratio (D) near unity, where the diode and the output capa ...
... Inverter systems with step-up transformers having a high turn’s ratio are generally bulky and noisy. Therefore, the alternate option is to go for a transformer- less design. The maximum gain of conventional boost converter is achieved at duty ratio (D) near unity, where the diode and the output capa ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.