krm-3k5-carrier_ds_1_0 - Knowledge Resources GmbH, Switzerland
... The PL Bank that is mapped to X2_1 is one of the two special purpose PL I/O banks. While the 50 pin Ziff header connectivity matches that of banks X1_1 and X1_2, there is no 2.54mm socket field available. It’s primary purpose is to allow the connection of a touch display which is available as an add ...
... The PL Bank that is mapped to X2_1 is one of the two special purpose PL I/O banks. While the 50 pin Ziff header connectivity matches that of banks X1_1 and X1_2, there is no 2.54mm socket field available. It’s primary purpose is to allow the connection of a touch display which is available as an add ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
... and 34BDA is maintained by two EAT on-load tap changers at the nominal 100 percent voltage. The bus voltage is maintained at the nominal 100 percent following a ± ten percent deviation in the switchyard voltage combined with bus voltage changes as a result of changes in bus loading. The EPSS connect ...
... and 34BDA is maintained by two EAT on-load tap changers at the nominal 100 percent voltage. The bus voltage is maintained at the nominal 100 percent following a ± ten percent deviation in the switchyard voltage combined with bus voltage changes as a result of changes in bus loading. The EPSS connect ...
MAX14627/MAX14628 Low-Power Headset Detectors with SEND/END Button Support General Description
... detecting the insertion and managing the operation of a 3.5mm stereo headset with a microphone. These devices integrate all circuitry needed to detect SEND/END button press events and generate required microphone bias voltages, and are fully compatible with Windows Mobile 7. The devices need only th ...
... detecting the insertion and managing the operation of a 3.5mm stereo headset with a microphone. These devices integrate all circuitry needed to detect SEND/END button press events and generate required microphone bias voltages, and are fully compatible with Windows Mobile 7. The devices need only th ...
S240-66-1
... We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our “Safety For Life” mission. ...
... We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our “Safety For Life” mission. ...
ABWR 2.12 Station Electrical Systems 2.12.1 Electrical Power Distribution System
... and RAT(s) are specified below. The plant EPD System can be supplied power from multiple power sources; these are independent transmission lines from the TN, the PMG, and the combustion turbine generator (CTG). In addition, the EPD System can be supplied from three onsite Class 1E Standby Power Sour ...
... and RAT(s) are specified below. The plant EPD System can be supplied power from multiple power sources; these are independent transmission lines from the TN, the PMG, and the combustion turbine generator (CTG). In addition, the EPD System can be supplied from three onsite Class 1E Standby Power Sour ...
conversion gain and interpixel capacitance
... In an effort to compare and validate the two methods of deriving the conversion gain we used the Kα line of Fe55 which generates a well known number of electrons per absorbed x-ray photon and has been in use for many years to calibrate the conversion gain of optical CCDs2. Unfortunately, the Fe55 me ...
... In an effort to compare and validate the two methods of deriving the conversion gain we used the Kα line of Fe55 which generates a well known number of electrons per absorbed x-ray photon and has been in use for many years to calibrate the conversion gain of optical CCDs2. Unfortunately, the Fe55 me ...
Earth Faults in Extensive Cable Networks
... system shall be constructed in such way that not even during a fault shall anyone be exposed to danger. The most common type of fault in the electrical distribution system is earth faults (Hänninen et al. 2001). During an earth fault, a current flows from the electric network to earth, at the fault ...
... system shall be constructed in such way that not even during a fault shall anyone be exposed to danger. The most common type of fault in the electrical distribution system is earth faults (Hänninen et al. 2001). During an earth fault, a current flows from the electric network to earth, at the fault ...
Riello UPS Dialog Dual DLD Series 5000-6000 Manual
... f) Do not switch the UPS on if there is any leak of liquid, or if a residual white powder is noted. g) Do not allow water, liquids in general and/or other foreign bodies to get into the UPS. h) In the event of dangerous conditions switch the UPS off with the switch located on the front panel and ope ...
... f) Do not switch the UPS on if there is any leak of liquid, or if a residual white powder is noted. g) Do not allow water, liquids in general and/or other foreign bodies to get into the UPS. h) In the event of dangerous conditions switch the UPS off with the switch located on the front panel and ope ...
UNIVERSITY OF CALICUT (Abstract)
... To equip the students with basic components in electronics, identifying and testing them, various measuring and testing instruments, assembling of electronic circuits and basic techniques of troubleshooting. Objectives of the Course ...
... To equip the students with basic components in electronics, identifying and testing them, various measuring and testing instruments, assembling of electronic circuits and basic techniques of troubleshooting. Objectives of the Course ...
MAX6922/MAX6932 - Maxim Part Number Search
... output resistances can be calculated from the VH and VL electrical characteristics. Use this calculated resistance to determine the output voltage drop at different output currents. ...
... output resistances can be calculated from the VH and VL electrical characteristics. Use this calculated resistance to determine the output voltage drop at different output currents. ...
$doc.title
... The THS4041 is a single, high-speed voltage Gain = 1 −6 RF = 200 Ω feedback amplifier capable of driving any capacitive RL = 150 Ω ...
... The THS4041 is a single, high-speed voltage Gain = 1 −6 RF = 200 Ω feedback amplifier capable of driving any capacitive RL = 150 Ω ...
ZTX751 Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA
... processing for control and monitoring. The system shall have the capability of operating in 2 modes, Double Conversion mode through inverter for supporting the critical load at all time with no switching during a power outage, or Green mode through static switch for better efficiency with fast trans ...
... processing for control and monitoring. The system shall have the capability of operating in 2 modes, Double Conversion mode through inverter for supporting the critical load at all time with no switching during a power outage, or Green mode through static switch for better efficiency with fast trans ...
trail charger based charging solutions
... of the voltage drop between the battery and the alternator). With this fact in mind, the starting voltage for the liftgate batteries is 13.5 volts. The circuit to charge the auxiliary liftgate batteries can be well over 60 feet (on trailer applications). All of this length and connections (including ...
... of the voltage drop between the battery and the alternator). With this fact in mind, the starting voltage for the liftgate batteries is 13.5 volts. The circuit to charge the auxiliary liftgate batteries can be well over 60 feet (on trailer applications). All of this length and connections (including ...
S230-30-1
... fused block banks is warranted for a period of one year from the date of shipment. Cooper Power Systems will, at its option, correct, by repair or replacement, capacitor blocks or components which may fail because of defects in material or workmanship. The warranty is valid only if the equipment has ...
... fused block banks is warranted for a period of one year from the date of shipment. Cooper Power Systems will, at its option, correct, by repair or replacement, capacitor blocks or components which may fail because of defects in material or workmanship. The warranty is valid only if the equipment has ...
+5V-Powered, Multichannel RS-232 Drivers/Receivers General Description Next-Generation Device Features
... ROUT........................................................-0.3V to (VCC + 0.3V) Short-Circuit Duration, TOUT to GND ........................Continuous Continuous Power Dissipation (TA = +70°C) 14-Pin Plastic DIP (derate 10.00mW/°C above +70°C)....800mW 16-Pin Plastic DIP (derate 10.53mW/°C above + ...
... ROUT........................................................-0.3V to (VCC + 0.3V) Short-Circuit Duration, TOUT to GND ........................Continuous Continuous Power Dissipation (TA = +70°C) 14-Pin Plastic DIP (derate 10.00mW/°C above +70°C)....800mW 16-Pin Plastic DIP (derate 10.53mW/°C above + ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.